Hydrocarbon resistant & fire retardant, 3C Cu Cond. CTS, GSTA and PVC sheath
Hydrocarbon resistant & fire retardant, 3C Cu Cond. CTS, GSTA and PVC sheath
M2N2G 3*120
Nexans ref. M2N2G 009053 - Country ref. M2N2G 3*120//FMCC
- Conductor diameter: 12.9 mm
- Nominal insulation thickness: 2.5 mm
- Nominal outer sheath thickness: 2.8 mm
- Nominal outer diameter: 53.0 mm
- Approximate net weight: 6281 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Perm current rating in air 30°C: 352 A
- Permissible current rating when buried: 298 A
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.196 Ohm/km
M2N2G 3*150
Nexans ref. M2N2G 009054 - Country ref. M2N2G 3*150//FMCC
- Conductor diameter: 14.2 mm
- Nominal insulation thickness: 2.5 mm
- Nominal outer sheath thickness: 2.9 mm
- Nominal outer diameter: 56.0 mm
- Approximate net weight: 7297 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Perm current rating in air 30°C: 397 A
- Permissible current rating when buried: 332 A
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.159 Ohm/km
M2N2G 3*185
Nexans ref. M2N2G 009055 - Country ref. M2N2G 3*185//FMCC
- Conductor diameter: 15.9 mm
- Nominal insulation thickness: 2.5 mm
- Nominal outer sheath thickness: 3.0 mm
- Nominal outer diameter: 60.0 mm
- Approximate net weight: 8585 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Perm current rating in air 30°C: 453 A
- Permissible current rating when buried: 374 A
- Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.128 Ohm/km
M2N2G 3*240
Nexans ref. M2N2G 009056 - Country ref. M2N2G 3*240//FMCC
- Conductor diameter: 18.1 mm
- Nominal insulation thickness: 2.6 mm
- Nominal outer sheath thickness: 3.2 mm
- Nominal outer diameter: 66.0 mm
- Approximate net weight: 10688 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Perm current rating in air 30°C: 529 A
- Permissible current rating when buried: 431 A
- Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.0981 Ohm/km
M2N2G 3*50
Nexans ref. M2N2G 009050 - Country ref. M2N2G 3*50//FMCC
- Conductor diameter: 8.1 mm
- Nominal insulation thickness: 2.5 mm
- Nominal outer sheath thickness: 2.4 mm
- Nominal outer diameter: 42.0 mm
- Approximate net weight: 3405 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Perm current rating in air 30°C: 205 A
- Permissible current rating when buried: 181 A
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.494 Ohm/km
M2N2G 3*70
Nexans ref. M2N2G 009051 - Country ref. M2N2G 3*70//FMCC
- Conductor diameter: 9.7 mm
- Nominal insulation thickness: 2.5 mm
- Nominal outer sheath thickness: 2.5 mm
- Nominal outer diameter: 46.0 mm
- Approximate net weight: 4268 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Perm current rating in air 30°C: 253 A
- Permissible current rating when buried: 220 A
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.342 Ohm/km
M2N2G 3*95
Nexans ref. M2N2G 009052 - Country ref. M2N2G 3*95//FMCC
- Conductor diameter: 11.4 mm
- Nominal insulation thickness: 2.5 mm
- Nominal outer sheath thickness: 2.7 mm
- Nominal outer diameter: 50.0 mm
- Approximate net weight: 5306 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
- Perm current rating in air 30°C: 307 A
- Permissible current rating when buried: 263 A
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.247 Ohm/km
M3N2G 3*120
Nexans ref. M3N2G 009050 - Country ref. M3N2G 3*120//FMCC
- Conductor diameter: 12.9 mm
- Nominal insulation thickness: 3.4 mm
- Nominal outer sheath thickness: 2.9 mm
- Nominal outer diameter: 57.0 mm
- Approximate net weight: 6718 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
- Perm current rating in air 30°C: 352 A
- Permissible current rating when buried: 298 A
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.196 Ohm/km
M3N2G 3*150
Nexans ref. M3N2G 009051 - Country ref. M3N2G 3*150//FMCC
- Conductor diameter: 14.2 mm
- Nominal insulation thickness: 3.4 mm
- Nominal outer sheath thickness: 3.0 mm
- Nominal outer diameter: 60.0 mm
- Approximate net weight: 7786 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
- Perm current rating in air 30°C: 397 A
- Permissible current rating when buried: 332 A
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.159 Ohm/km
M3N2G 3*185
Nexans ref. M3N2G 009052 - Country ref. M3N2G 3*185//FMCC
- Conductor diameter: 15.9 mm
- Nominal insulation thickness: 3.4 mm
- Nominal outer sheath thickness: 3.1 mm
- Nominal outer diameter: 64.0 mm
- Approximate net weight: 9102 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
- Perm current rating in air 30°C: 453 A
- Permissible current rating when buried: 374 A
- Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.128 Ohm/km
M3N2G 3*240
Nexans ref. M3N2G 009053 - Country ref. M3N2G 3*240//FMCC
- Conductor diameter: 18.1 mm
- Nominal insulation thickness: 3.4 mm
- Nominal outer sheath thickness: 3.3 mm
- Nominal outer diameter: 69.0 mm
- Approximate net weight: 11185 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
- Perm current rating in air 30°C: 529 A
- Permissible current rating when buried: 431 A
- Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.0981 Ohm/km
Description
Description
Standards
-
ProductIEC 60502-2
-
TestIEC 60332-1-2; IEC 60332-3
Scope
This specification covers three cores armoured cables, conforming to IEC 60502-2 Specifications.
Construction
2.1 Conductor
Plain, annealed electrolytic copper conductors, circular stranded,conforming to the applicable requirements of IEC 60228.
2.2 Insulation
Extruded inner semi conductive layer, XLPE insulation and extruded outer semi conductive layer .
2.3 Metallic Screen Layer
Copper tape on each core
2.4 Separation Sheath
Special Hydrocarbon resistant and fire retardant PVC .
2.5 Armour
GALVANIZED STEEL TAPE .
2.5 Sheath
Special Hydrocarbon resistant and fire retardant PVC .
Tests
All tests required by IEC 60502-2 either on Raw material or on finished products.
TEST AT WORKS ARMORED CABLES ACCORDING TO IEC 60502-2 & IEC 60332-3
Routine Tests
- Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-2 parag.16.1 & 16.2
- High voltage test acc. to IEC 60502-2 parag. 16.1 & 16.4
- Max. partial discharge test at 1.73 Uo acc. to IEC 60502-2 parag.16.1 & 16.3
Liban Cables will carry out these tests on all the lengths and tests certificates will be provided.
Sample Tests
- Check of the build - up and color coding of the cable
- Check of dimensions
Insulation : according to IEC 60502-2 Parag. 17.5.2
Separation sheath : according to IEC 60502-2 Parag. 17.5.3
Armouring : according to IEC 60502-2 Parag. 17.7
Oversheath : according to IEC 60502-2 Parag. 17.5.3
- Hot Set Test : according to IEC 60502-2 Parag. 17.10
These tests will be carried out on one length of each size during each inspection .
Tests certificates will be provided by Liban Cables
Type Tests
Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-2.
Fire retardance test according to IEC 60332-3.
These tests will be carried out on one length of the order .
Tests certificates will be provided by Liban Cables
DRAWING MV 3C GSTA ARMORED
DRAWING GSTA MV
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania