Specification / Specyfikacja: MEDIUM VOLTAGE UNARMOURED CABLE CONFORMING TO IEC 60502-2 / KABLE ELEKTROENERGETYCZNE ŚREDNIEGO NAPIĘCIA, NIEOPANCERZONE, ZGODNE Z IEC 60502-2
Read moreXRUHAKXSa 1*120/45 18/30KV
Nexans ref. M6AA4DP000210 - Country ref. M6AA4DP 1*120/45(FL)//POL-1
- Packaging: Drum
- Conductor cross-section: 120 mm²
- Conductor diameter: 12.8 mm
- Screen section: 45 mm²
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 39.0 mm
- Approximate net weight: 1280 kg/km
- Perm current rating in air 30°C: 324 A
- Permissible current rating when buried: 252 A
- Max. DC resistance of the conductor at 20°C: 0.253 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.323 Ohm/km
- Permissible short circuit current conductor 1s: 11.6 kA
- Permissible short circuit current screen 1s: 4.25 kA
XRUHAKXSa 1*150/60 18/30KV
Nexans ref. M6AA4DP700105 - Country ref. M6AA4DP 1*150/60(FL)//POL-1
- Packaging: Drum
- Conductor cross-section: 150 mm²
- Conductor diameter: 14.35 mm
- Screen section: 60 mm²
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 41.0 mm
- Approximate net weight: 1456 kg/km
- Perm current rating in air 30°C: 368 A
- Permissible current rating when buried: 281 A
- Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.264 Ohm/km
- Permissible short circuit current conductor 1s: 14.5 kA
- Permissible short circuit current screen 1s: 5.65 kA
XRUHAKXSa 1*150/70 18/30KV
Nexans ref. M6AA4DP700113 - Country ref. M6AA4DP 1*150/70(FL)//POL-1
- Packaging: Drum
- Conductor cross-section: 150 mm²
- Conductor diameter: 14.35 mm
- Screen section: 70 mm²
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 41.0 mm
- Approximate net weight: 1482 kg/km
- Perm current rating in air 30°C: 368 A
- Permissible current rating when buried: 281 A
- Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.264 Ohm/km
- Permissible short circuit current conductor 1s: 14.5 kA
- Permissible short circuit current screen 1s: 6.85 kA
XRUHAKXSa 1*240/45 18/30KV
Nexans ref. M6AA4DP000211 - Country ref. M6AA4DP 1*240/45(FL)//POL-1
- Packaging: Drum
- Conductor cross-section: 240 mm²
- Conductor diameter: 17.9 mm
- Screen section: 45 mm²
- Nominal outer sheath thickness: 2.4 mm
- Nominal outer diameter: 44.0 mm
- Approximate net weight: 1778 kg/km
- Perm current rating in air 30°C: 502 A
- Permissible current rating when buried: 367 A
- Max. DC resistance of the conductor at 20°C: 0.125 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.161 Ohm/km
- Permissible short circuit current conductor 1s: 23.1 kA
- Permissible short circuit current screen 1s: 4.25 kA
XRUHAKXSa 1*240/60 18/30KV
Nexans ref. M6AA4DP000212 - Country ref. M6AA4DP 1*2400/60(FL)//POL-1
- Packaging: Drum
- Conductor cross-section: 240 mm²
- Conductor diameter: 17.9 mm
- Screen section: 60 mm²
- Nominal outer sheath thickness: 2.3 mm
- Nominal outer diameter: 44.0 mm
- Approximate net weight: 1797 kg/km
- Perm current rating in air 30°C: 502 A
- Permissible current rating when buried: 367 A
- Max. DC resistance of the conductor at 20°C: 0.125 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.161 Ohm/km
- Permissible short circuit current conductor 1s: 23.1 kA
- Permissible short circuit current screen 1s: 5.65 kA
XRUHAKXSa 1*240/70 18/30KV
Nexans ref. M6AA4DP000213 - Country ref. M6AA4DP 1*240/70(FL)//POL-1
- Packaging: Drum
- Conductor cross-section: 240 mm²
- Conductor diameter: 17.9 mm
- Screen section: 70 mm²
- Nominal outer sheath thickness: 2.4 mm
- Nominal outer diameter: 45.0 mm
- Approximate net weight: 1859 kg/km
- Perm current rating in air 30°C: 502 A
- Permissible current rating when buried: 367 A
- Max. DC resistance of the conductor at 20°C: 0.125 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.161 Ohm/km
- Permissible short circuit current conductor 1s: 23.1 kA
- Permissible short circuit current screen 1s: 6.85 kA
XRUHAKXSa 1*240/80 18/30KV
Nexans ref. M6AA4DP000209 - Country ref. M6AA4DP 1*240/80(FL)//POL-1
- Packaging: Drum
- Conductor cross-section: 240 mm²
- Conductor diameter: 17.9 mm
- Screen section: 80 mm²
- Nominal outer sheath thickness: 2.4 mm
- Nominal outer diameter: 45.0 mm
- Approximate net weight: 1892 kg/km
- Perm current rating in air 30°C: 502 A
- Permissible current rating when buried: 367 A
- Max. DC resistance of the conductor at 20°C: 0.125 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.161 Ohm/km
- Permissible short circuit current conductor 1s: 23.1 kA
- Permissible short circuit current screen 1s: 7.5 kA
XRUHAKXSa 1*500/80 18/30KV
Nexans ref. M6AA4DP100108 - Country ref. M6AA4DP 1*500/80(FL)//POL-1
- Packaging: Drum
- Conductor cross-section: 500 mm²
- Conductor diameter: 26.2 mm
- Screen section: 80 mm²
- Nominal outer sheath thickness: 2.6 mm
- Nominal outer diameter: 54.0 mm
- Approximate net weight: 2938 kg/km
- Perm current rating in air 30°C: 789 A
- Permissible current rating when buried: 537 A
- Max. DC resistance of the conductor at 20°C: 0.0605 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.0794 Ohm/km
- Permissible short circuit current conductor 1s: 47.9 kA
- Permissible short circuit current screen 1s: 7.5 kA
XRUHAKXSa 1*630/80 18/30KV
Nexans ref. M6AA4DP100104 - Country ref. M6AA4DP 1*630/80(FL)//POL-1
- Packaging: Drum
- Conductor cross-section: 630 mm²
- Conductor diameter: 29.6 mm
- Screen section: 80 mm²
- Nominal outer sheath thickness: 2.7 mm
- Nominal outer diameter: 57.0 mm
- Approximate net weight: 3738 kg/km
- Perm current rating in air 30°C: 916 A
- Permissible current rating when buried: 611 A
- Max. DC resistance of the conductor at 20°C: 0.0469 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.0626 Ohm/km
- Permissible short circuit current conductor 1s: 60.2 kA
- Permissible short circuit current screen 1s: 7.5 kA
XRUHAKXSa 1*95/60 18/30KV
Nexans ref. M6AA4DP700111 - Country ref. M6AA4DP 1*95/60(FL)//POL-1
- Packaging: Drum
- Conductor cross-section: 95 mm²
- Conductor diameter: 11.65 mm
- Screen section: 60 mm²
- Nominal outer sheath thickness: 2.1 mm
- Nominal outer diameter: 38.0 mm
- Approximate net weight: 1221 kg/km
- Perm current rating in air 30°C: 280 A
- Permissible current rating when buried: 221 A
- Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.41 Ohm/km
- Permissible short circuit current conductor 1s: 9.2 kA
- Permissible short circuit current screen 1s: 5.65 kA
XRUHAKXSa 1*95/70 18/30KV
Nexans ref. M6AA4DP700114 - Country ref. M6AA4DP 1*95/70(FL)//POL-1
- Packaging: Drum
- Conductor cross-section: 95 mm²
- Conductor diameter: 11.65 mm
- Screen section: 70 mm²
- Nominal outer sheath thickness: 2.1 mm
- Nominal outer diameter: 38.0 mm
- Approximate net weight: 1246 kg/km
- Perm current rating in air 30°C: 280 A
- Permissible current rating when buried: 221 A
- Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.41 Ohm/km
- Permissible short circuit current conductor 1s: 9.2 kA
- Permissible short circuit current screen 1s: 6.85 kA
Description
Description
Standards
-
ProductIEC 60502-2
DESCRIPTION: AL/SC/XLPE/SC/SC SWEL/ALU WIRES/SWEL/ALLUPE/PE
OPIS: AL/S.C/XLPE/S.C/S.C. Włóknina. pęczn./druty Alu/Włóknina.pęczn./ALUCOPO/PE
1. Conductor / żyła:
Aluminium stranded class 2 acc. To IEC 60228 / aluminiowa wielodrutowa klasa 2 zgodnie z IEC 60228
2. Conductor screen / ekran żyły:
Extruded semi-conductor bonded to the XLPE insulation / wytłoczony półprzewodzący zespojony z izolacją z XLPE
3. Insulation / izolacja:
XLPE / XLPE
4. Insulation screen / ekran izolacji:
Extruded semi-conductor bonded to the XLPE insulation / wytłoczony półprzewodzący zespojony z izolacją z XLPE
5. Water proof tape / taśma zapewniająca wodoszczelność:
Semi-conductor swelling tape / półprzewodząca włóknina pęczniejąca
6. Screen / ekran:
Aluminum wires / Przewody aluminiowe
7. Water proof tape / taśma zapewniająca wodoszczelność:
Swelling tape / włóknina pęczniejąca
8. Radial water proof barrier / poprzeczna bariera wodoszczelna:
Longitudinal aluminium PE coated tape / wzdłużna taśma powlekana AL/PE
9. Oversheath / powłoka zewnętrzna:
PE / PE
TEST AT WORKS / PRÓBY FABRYCZNE
Routine Tests / Badania rutynowe:
• Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-2 parag.16.2 / Maks. rezystancja DC żył w temperaturze 20°C zgodnie z IEC 60228 i IEC 60502-2 pkt 16.2
• High voltage test acc. to IEC 60502-2 parag. 16.4 / Próba wysokim napięciem zgodnie z IEC 60502-2 pkt 16.4
• Max. partial discharge test at 1.73 Uo acc. to IEC 60502-2 parag. 16.3 / Badanie maksymalnych wyładowań niezupełnych przy 1,73 Uo zgodnie z IEC 60502-2 pkt 16.3
Liban Cables will carry out these tests on all the lengths and tests certificates will be provided / Firma Liban Cables przeprowadzi te badania dla wszystkich odcinków kabli i dostarczy świadectwa z badań
Sample tests / Badania próbek:
• Check of the build - up and color coding of the cable / Sprawdzenie rozwijania i kolorowych oznaczeń kabla
• Check of dimensions / Sprawdzenie wymiarów
Insulation / Izolacja : according to IEC 60502-2 / zgodnie z IEC 60502-2 Parag. / pkt. 17.5.2
Metallic screen / Ekran metaliczny : according to IEC 60502-2 / zgodnie z IEC 60502-2 Parag. / pkt. 17.7
Oversheath / Powłoka zewnętrzna : according to IEC 60502-2 / zgodnie z IEC 60502-2 Parag. / pkt. 17.5.3
- Hot Set Test for XLPE insulation according to IEC 60502-2 parag. 17.10 /-Badanie stopnia usieciowania izolacji z XLPE zgodnie z IEC 60502-2 pkt 17.10
These tests will be carried out on one length of each size during each inspection . / Badania te – podczas każdej kontroli – zostaną przeprowadzone na jednym odcinku dla każdego rozmiaru kabla.
Tests certificates will be provided by Liban Cables / Świadectwa z badań dostarczy firma Liban Cables
Type tests / Próby typu
Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break ) in accordance with IEC 60502-2. / Charakterystyki mechaniczne materiałów izolacji i powłoki zewnętrznej (wytrzymałość na rozciąganie i wydłużenie przy zerwaniu) zgodnie z IEC 60502-2.
These tests will be carried out on one length of the order / Badania te zostaną przeprowadzone na jednym odcinku z zamówienia
Tests certificates will be provided by Liban Cables / Świadectwa z badań dostarczy firma Liban Cables
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania