AL, Multicore Armored, XLPE insulated, PVC sheathed
AL, Multicore Armored, XLPE insulated, PVC sheathed
0.6 / 1 KV POWER CABLES
Conforming to IEC 60502-1
EAXG 4*150SM
Nexans ref. EAXG 000148 - Country ref. EAXG 4*150SM
- Conductor shape: Shaped
- Number of conductors: 4
- Armour type: Galvanized steel tapes
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 1.4 mm
- Nominal armour wire diameter: 0.5 mm
- Nominal outer sheath thickness: 2.5 mm
- Nominal outer diameter: 48.0 mm
- Approximate weight: 3216 kg/km
- Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
- Permissible current rating in open air: 309 A
- Permissible current rating when buried: 301 A
EAXG 4*16
Nexans ref. EAXG 000140 - Country ref. EAXG 4*16
- Conductor shape: Circular
- Number of conductors: 4
- Armour type: Galvanized steel tapes
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 0.2 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 21.0 mm
- Approximate weight: 536 kg/km
- Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
- Permissible current rating in open air: 75 A
- Permissible current rating when buried: 87 A
EAXG 4*185SM
Nexans ref. EAXG...000150 - Country ref. EAXG 4*185SM
- Conductor shape: Shaped
- Number of conductors: 4
- Armour type: Galvanized steel tapes
- Conductor cross-section: 185 mm²
- Nominal insulation thickness: 1.6 mm
- Nominal armour wire diameter: 0.5 mm
- Nominal outer sheath thickness: 2.7 mm
- Nominal outer diameter: 53.0 mm
- Approximate weight: 3917 kg/km
- Max. DC resistance of the conductor at 20°C: 0.164 Ohm/km
- Permissible current rating in open air: 353 A
- Permissible current rating when buried: 339 A
EAXG 4*25
Nexans ref. EAXG 000125 - Country ref. EAXG 4*25
- Conductor shape: Circular
- Number of conductors: 4
- Armour type: Galvanized steel tapes
- Conductor cross-section: 25 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 0.2 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 25.0 mm
- Approximate weight: 833 kg/km
- Max. DC resistance of the conductor at 20°C: 1.2 Ohm/km
- Permissible current rating in open air: 99 A
- Permissible current rating when buried: 110 A
EAXG 4*300SM
Nexans ref. EAXG 000156 - Country ref. EAXG 4*300SM
- Conductor shape: Shaped
- Number of conductors: 4
- Armour type: Galvanized steel tapes
- Conductor cross-section: 300 mm²
- Nominal insulation thickness: 1.8 mm
- Nominal armour wire diameter: 0.5 mm
- Nominal outer sheath thickness: 3.1 mm
- Nominal outer diameter: 65.0 mm
- Approximate weight: 5812 kg/km
- Max. DC resistance of the conductor at 20°C: 0.1 Ohm/km
- Permissible current rating in open air: 472 A
- Permissible current rating when buried: 495 A
EAXG 4*35
Nexans ref. EAXG...000625 - Country ref. EAXG 4*35
- Conductor shape: Circular
- Number of conductors: 4
- Armour type: Galvanized steel tapes
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 0.2 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 27.0 mm
- Approximate weight: 938 kg/km
- Max. DC resistance of the conductor at 20°C: 0.868 Ohm/km
- Permissible current rating in open air: 125 A
- Permissible current rating when buried: 133 A
EAXG 4*50
Nexans ref. EAXG 000725 - Country ref. EAXG 4*50
- Conductor shape: Circular
- Number of conductors: 4
- Armour type: Galvanized steel tapes
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal armour wire diameter: 0.2 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 31.0 mm
- Approximate weight: 1201 kg/km
- Max. DC resistance of the conductor at 20°C: 0.641 Ohm/km
- Permissible current rating in open air: 151 A
- Permissible current rating when buried: 159 A
EAXG 4*70SM
Nexans ref. EAXG 000137 - Country ref. EAXG 4*70SM
- Conductor shape: Shaped
- Number of conductors: 4
- Armour type: Galvanized steel tapes
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal armour wire diameter: 0.2 mm
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 34.0 mm
- Approximate weight: 1494 kg/km
- Max. DC resistance of the conductor at 20°C: 0.443 Ohm/km
- Permissible current rating in open air: 192 A
- Permissible current rating when buried: 197 A
EAXR 2*25
Nexans ref. EAXR 001430 - Country ref. EAXR 2*25
- Conductor shape: Circular
- Number of conductors: 2
- Armour type: Galvanized steel wires
- Conductor cross-section: 25 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 23.0 mm
- Approximate weight: 918 kg/km
- Max. DC resistance of the conductor at 20°C: 1.2 Ohm/km
- Permissible current rating in open air: 111 A
- Permissible current rating when buried: 126 A
EAXR 3*120SM
Nexans ref. EAXR 004178 - Country ref. EAXR 3*120SM
- Conductor shape: Shaped
- Number of conductors: 3
- Armour type: Galvanized steel wires
- Conductor cross-section: 120 mm²
- Nominal insulation thickness: 1.2 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer sheath thickness: 2.3 mm
- Nominal outer diameter: 40.0 mm
- Approximate weight: 2773 kg/km
- Max. DC resistance of the conductor at 20°C: 0.253 Ohm/km
- Permissible current rating in open air: 269 A
- Permissible current rating when buried: 269 A
EAXR 3*150SM
Nexans ref. EAXR 004180 - Country ref. EAXR 3*150SM
- Conductor shape: Shaped
- Number of conductors: 3
- Armour type: Galvanized steel wires
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 1.4 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 2.5 mm
- Nominal outer diameter: 48.0 mm
- Approximate weight: 3830 kg/km
- Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
- Permissible current rating in open air: 309 A
- Permissible current rating when buried: 301 A
EAXR 3*185SM
Nexans ref. EAXR 004190 - Country ref. EAXR 3*185SM
- Conductor shape: Shaped
- Number of conductors: 3
- Armour type: Galvanized steel wires
- Conductor cross-section: 185 mm²
- Nominal insulation thickness: 1.6 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 2.6 mm
- Nominal outer diameter: 50.0 mm
- Approximate weight: 4345 kg/km
- Max. DC resistance of the conductor at 20°C: 0.164 Ohm/km
- Permissible current rating in open air: 353 A
- Permissible current rating when buried: 339 A
EAXR 3*240SM
Nexans ref. EAXR 004200 - Country ref. EAXR 3*240SM
- Conductor shape: Shaped
- Number of conductors: 3
- Armour type: Galvanized steel wires
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 1.7 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 2.8 mm
- Nominal outer diameter: 56.0 mm
- Approximate weight: 5210 kg/km
- Max. DC resistance of the conductor at 20°C: 0.125 Ohm/km
- Permissible current rating in open air: 415 A
- Permissible current rating when buried: 393 A
EAXR 3*300SM
Nexans ref. EAXR 000800 - Country ref. EAXR 3*300SM
- Conductor shape: Shaped
- Number of conductors: 3
- Armour type: Galvanized steel wires
- Conductor cross-section: 300 mm²
- Nominal insulation thickness: 1.8 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 3.0 mm
- Nominal outer diameter: 61.0 mm
- Approximate weight: 6119 kg/km
- Max. DC resistance of the conductor at 20°C: 0.1 Ohm/km
- Permissible current rating in open air: 472 A
- Permissible current rating when buried: 495 A
EAXR 3*35
Nexans ref. EAXR 000802 - Country ref. EAXR 3*35
- Conductor shape: Circular
- Number of conductors: 3
- Armour type: Galvanized steel wires
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 27.0 mm
- Approximate weight: 1218 kg/km
- Max. DC resistance of the conductor at 20°C: 8.868 Ohm/km
- Permissible current rating in open air: 125 A
- Permissible current rating when buried: 133 A
EAXR 3*400
Nexans ref. EAXR 005045 - Country ref. EAXR 3*400
- Conductor shape: Circular
- Number of conductors: 3
- Armour type: Galvanized steel wires
- Conductor cross-section: 400 mm²
- Nominal insulation thickness: 2.0 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 3.2 mm
- Nominal outer diameter: 72.0 mm
- Approximate weight: 7944 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0778 Ohm/km
- Permissible current rating in open air: 551 A
- Permissible current rating when buried: 512 A
EAXR 3*70SM
Nexans ref. EAXR 004160 - Country ref. EAXR 3*70SM
- Conductor shape: Shaped
- Number of conductors: 3
- Armour type: Galvanized steel wires
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 33.0 mm
- Approximate weight: 1947 kg/km
- Max. DC resistance of the conductor at 20°C: 0.443 Ohm/km
- Permissible current rating in open air: 192 A
- Permissible current rating when buried: 197 A
EAXR 3*95SM
Nexans ref. EAXR 003295 - Country ref. EAXR 3*95SM
- Conductor shape: Shaped
- Number of conductors: 3
- Armour type: Galvanized steel wires
- Conductor cross-section: 95 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 37.0 mm
- Approximate weight: 2371 kg/km
- Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
- Permissible current rating in open air: 232 A
- Permissible current rating when buried: 236 A
EAXR 4*120SM
Nexans ref. EAXR 004450 - Country ref. EAXR 4*120SM
- Conductor shape: Shaped
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 120 mm²
- Nominal insulation thickness: 1.2 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 2.5 mm
- Nominal outer diameter: 47.0 mm
- Approximate weight: 3874 kg/km
- Max. DC resistance of the conductor at 20°C: 0.253 Ohm/km
- Permissible current rating in open air: 269 A
- Permissible current rating when buried: 269 A
EAXR 4*150SM NEW
Nexans ref. EAXR 004452 - Country ref. EAXR 4*150SM
- Conductor shape: Shaped
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 1.4 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 2.6 mm
- Nominal outer diameter: 51.0 mm
- Approximate weight: 4481 kg/km
- Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
- Permissible current rating in open air: 309 A
- Permissible current rating when buried: 301 A
EAXR 4*16
Nexans ref. EAXR 004428 - Country ref. EAXR 4*16
- Conductor shape: Circular
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 23.0 mm
- Approximate weight: 963 kg/km
- Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
- Permissible current rating in open air: 75 A
- Permissible current rating when buried: 87 A
EAXR 4*185SM
Nexans ref. EAXR 004449 - Country ref. EAXR 4*185SM
- Conductor shape: Shaped
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 185 mm²
- Nominal insulation thickness: 1.6 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 2.8 mm
- Nominal outer diameter: 56.0 mm
- Approximate weight: 5355 kg/km
- Max. DC resistance of the conductor at 20°C: 0.164 Ohm/km
- Permissible current rating in open air: 353 A
- Permissible current rating when buried: 339 A
EAXR 4*240SM NEW
Nexans ref. EAXR 004480 - Country ref. EAXR 4*240SM
- Conductor shape: Shaped
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 1.7 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 3.0 mm
- Nominal outer diameter: 62.0 mm
- Approximate weight: 6438 kg/km
- Max. DC resistance of the conductor at 20°C: 0.125 Ohm/km
- Permissible current rating in open air: 415 A
- Permissible current rating when buried: 393 A
EAXR 4*25
Nexans ref. EAXR 004430 - Country ref. EAXR 4*25
- Conductor shape: Circular
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 25 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 27.0 mm
- Approximate weight: 1279 kg/km
- Max. DC resistance of the conductor at 20°C: 1.2 Ohm/km
- Permissible current rating in open air: 99 A
- Permissible current rating when buried: 110 A
EAXR 4*300SM NEW
Nexans ref. EAXR 004300 - Country ref. EAXR 4*300SM
- Conductor shape: Shaped
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 300 mm²
- Nominal insulation thickness: 1.8 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 3.2 mm
- Nominal outer diameter: 68.0 mm
- Approximate weight: 7593 kg/km
- Max. DC resistance of the conductor at 20°C: 0.1 Ohm/km
- Permissible current rating in open air: 472 A
- Permissible current rating when buried: 495 A
EAXR 4*400 NEW
Nexans ref. EAXR 004456 - Country ref. EAXR 4*400
- Conductor shape: Circular
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 400 mm²
- Nominal insulation thickness: 2.0 mm
- Nominal armour wire diameter: 3.15 mm
- Nominal outer sheath thickness: 3.5 mm
- Nominal outer diameter: 82.0 mm
- Approximate weight: 10729 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0778 Ohm/km
- Permissible current rating in open air: 551 A
- Permissible current rating when buried: 512 A
EAXR 4*50
Nexans ref. EAXR 000306 - Country ref. EAXR 4*50
- Conductor shape: Circular
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 33.0 mm
- Approximate weight: 1765 kg/km
- Max. DC resistance of the conductor at 20°C: 0.641 Ohm/km
- Permissible current rating in open air: 151 A
- Permissible current rating when buried: 159 A
EAXR 4*70SM
Nexans ref. EAXR 004439 - Country ref. EAXR 4*70SM
- Conductor shape: Shaped
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 37.0 mm
- Approximate weight: 2378 kg/km
- Max. DC resistance of the conductor at 20°C: 0.443 Ohm/km
- Permissible current rating in open air: 192 A
- Permissible current rating when buried: 197 A
EAXR 4*95SM
Nexans ref. EAXR 004442 - Country ref. EAXR 4*95SM
- Conductor shape: Shaped
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 95 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer sheath thickness: 2.3 mm
- Nominal outer diameter: 41.0 mm
- Approximate weight: 2908 kg/km
- Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
- Permissible current rating in open air: 232 A
- Permissible current rating when buried: 236 A
EAXR 5*16
Nexans ref. EAXR 100525 - Country ref. EAXR 5*16
- Conductor shape: Circular
- Number of conductors: 5
- Armour type: Galvanized steel wires
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 24.0 mm
- Approximate weight: 1043 kg/km
- Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
- Permissible current rating in open air: 75 A
- Permissible current rating when buried: 87 A
EAXR 5*25
Nexans ref. EAXR 000525 - Country ref. EAXR 5*25
- Conductor shape: Circular
- Number of conductors: 5
- Armour type: Galvanized steel wires
- Conductor cross-section: 25 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 29.0 mm
- Approximate weight: 1377 kg/km
- Max. DC resistance of the conductor at 20°C: 1.2 Ohm/km
- Permissible current rating in open air: 99 A
- Permissible current rating when buried: 110 A
EAXR 5*35
Nexans ref. EAXR 105851 - Country ref. EAXR 5*35
- Conductor shape: Circular
- Number of conductors: 5
- Armour type: Galvanized steel wires
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 32.0 mm
- Approximate weight: 1646 kg/km
- Max. DC resistance of the conductor at 20°C: 8.868 Ohm/km
- Permissible current rating in open air: 125 A
- Permissible current rating when buried: 133 A
EAXR 5*50
Nexans ref. EAXR 005851 - Country ref. EAXR 5*50
- Conductor shape: Circular
- Number of conductors: 5
- Armour type: Galvanized steel wires
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer sheath thickness: 2.1 mm
- Nominal outer diameter: 37.0 mm
- Approximate weight: 2297 kg/km
- Max. DC resistance of the conductor at 20°C: 0.641 Ohm/km
- Permissible current rating in open air: 151 A
- Permissible current rating when buried: 159 A
EAXR 5*70
Nexans ref. EAXR 005850 - Country ref. EAXR 5*70
- Conductor shape: Circular
- Number of conductors: 5
- Armour type: Galvanized steel wires
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 42.0 mm
- Approximate weight: 2883 kg/km
- Max. DC resistance of the conductor at 20°C: 0.443 Ohm/km
- Permissible current rating in open air: 192 A
- Permissible current rating when buried: 197 A
EAXR 5*95
Nexans ref. EAXR 005849 - Country ref. EAXR 5*95
- Conductor shape: Circular
- Number of conductors: 5
- Armour type: Galvanized steel wires
- Conductor cross-section: 95 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 2.4 mm
- Nominal outer diameter: 50.0 mm
- Approximate weight: 4082 kg/km
- Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
- Permissible current rating in open air: 232 A
- Permissible current rating when buried: 236 A
Description
Description
Standards
-
InternationalIEC 60228; IEC 60332-1-2; IEC 60502-1
1. SCOPE
This specification covers XLPE insulated, circular or shaped, multicore armoured cables, rated at 0.6/1 KV according to IEC 60502-1 for use indoors, outdoors, in cable ducts and for direct burial underground, where severe mechanical stresses are present.
2. CONSTRUCTION
2.1 Conductor
Aluminum conductors, circular stranded, or sectoral stranded, conforming to the applicable requirements of IEC 60228.
2.2 Insulation
XLPE thermosetting material, conforming to the applicable requirements of IEC 60502-1.
2.3 Assembly
Insulated conductors are laid up, filled where necessary with non-hygroscopic material and covered with an extruded thickness of thermoplastic material.
2.4 Armour
Galvanized round wires or steel tapes completely covering the assembly of cores complying to the applicable requirements of IEC 60502-1.
2.5 Sheath
PVC based thermoplastic material, conforming to the applicable requirements of IEC 60502-1.
2.6 TESTS
Conforming to the applicable requirements of IEC 60502-1 either on Raw materials or on finished products.
TEST AT WORKS according to IEC 60502-1 armored
Routine Tests
- Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag. 15.1 & 15.2
- Voltage test acc. to IEC 60502-1 parag. 15.1 & 15.3
Liban Cables will carry out these tests on all the lengths and tests certificates will be provided.
Sample Tests
- Check of the build - up and color coding of the cable
- Check of dimensions
Insulation: according to IEC 60502-1 Parag. 16.5.2
Armour: according to IEC 60502-1 Parag. 16.7
Oversheath: according to IEC 60502-1 Parag. 16.5.3
These tests will be carried out on one length of each size during each inspection .
Tests certificates will be provided by Liban Cables
Type Tests
Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-1.
These tests will be carried out on one length of the order .
Tests certificates will be provided by Liban Cables
Cable identification - LV cables ≤ 1KV
INSULATION COLORS:
|
Neutral |
Cond.1 |
Cond.2 |
Cond.3 |
Cond.4 |
1 Conductor |
|
BLACK |
|
|
|
2 Conductors |
GREY |
BLACK |
|
|
|
3 Conductors |
|
BLACK |
RED |
BLUE |
|
4 Conductors |
GREY |
BLACK |
RED |
BLUE |
|
5 Conductors |
GREY |
BLACK |
RED |
BLUE |
GREEN |
All numbered control cables (6 conductors and above), are insulated with white color, and numbered with black digits
CABLE MARKING OVER THE OUTER JACKET (by inkjet printing):
LIBAN CABLES DESCRIPTION RATED VOLTAGE SECTION MM2 Year of manufacture meter marking
Other cable identification requirements are available upon request
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania