EAXT ABC cables with Messenger 70 mm²

Products

EAXT 3*120+70//E

Nexans ref. EAXT 000327 - Country ref. EAXT 3*120+70//E

  • Number of conductors: 4
  • Nominal insulation thickness: 1.8 mm
  • Messenger insulation thickness: 1.5 mm
  • Conductor cross-section: 120 mm²
  • Nominal overall diameter: 40.0 mm
  • Approximate weight: 1490 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.253 Ohm/km
  • Perm current rating in air 30°C: 299 A

 

EAXT 3*150+70+16//E

Nexans ref. EAXT 000403 - Country ref. EAXT 3*150+70+16//E

  • Number of conductors: 5
  • Nominal insulation thickness: 0.7 mm
  • Messenger insulation thickness: 1.6 mm
  • Conductor cross-section: 150 mm²
  • Nominal overall diameter: 45.0 mm
  • Approximate weight: 1700 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
  • Perm current rating in air 30°C: 344 A

 

EAXT 3*150+70+16//EDL-SP

Nexans ref. EAXT 004921 - Country ref. EAXT 3*150+70+16//EDL-SP

  • Number of conductors: 5
  • Nominal insulation thickness: 0.7 mm
  • Messenger insulation thickness: 1.6 mm
  • Conductor cross-section: 150 mm²
  • Nominal overall diameter: 45.0 mm
  • Approximate weight: 1700 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
  • Perm current rating in air 30°C: 344 A

 

EAXT 3*150+70+16//KAD

Nexans ref. EAXT 000145 - Country ref. EAXT 3*150+70+16//KAD

  • Number of conductors: 5
  • Nominal insulation thickness: 0.7 mm
  • Messenger insulation thickness: 1.6 mm
  • Conductor cross-section: 150 mm²
  • Nominal overall diameter: 45.0 mm
  • Approximate weight: 1700 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
  • Perm current rating in air 30°C: 344 A

 

EAXT 3*150+70//E

Nexans ref. EAXT 000875 - Country ref. EAXT 3*150+70//E

  • Packaging: Drum (m)
  • Number of conductors: 4
  • Nominal insulation thickness: 1.5 mm
  • Messenger insulation thickness: 1.6 mm
  • Conductor cross-section: 150 mm²
  • Nominal overall diameter: 41.0 mm
  • Approximate weight: 1636 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
  • Perm current rating in air 30°C: 344 A

 

EAXT 3*95+70//E

Nexans ref. EAXT 000872 - Country ref. EAXT 3*95+70//E

  • Packaging: Drum (m)
  • Number of conductors: 4
  • Nominal insulation thickness: 1.8 mm
  • Messenger insulation thickness: 1.5 mm
  • Conductor cross-section: 95 mm²
  • Nominal overall diameter: 36.0 mm
  • Approximate weight: 1223 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
  • Perm current rating in air 30°C: 258 A

 

Description

Description

Standards

  • International
    IEC 60502-1
  • National
    NF C33-209

Application

Network distribution bundled conductors with neutral messenger are designed for rural and urban areas.

Some important cable characteristics are :

  • Ultraviolet radiation resistance,
  • Ozone resistance,
  • High dielectric strength,
  • Light and easy to handle.

 

Installation

These cables are NOT ALLOWED to be buried, even in conduits.

 

Description

The bundled conductor cables have aluminum conductors, insulated with XLPE, they have good durability and thermal resistance.

 

Messenger characteristics

  • core : circular stranded aluminum alloy, cross section area 70 mm²
  • Insulation : Black XLPE
  • nominal cross section : 70 mm²
  • nominal insulation thickness: 1.5 mm

 

Electrical characteristics

  • Rated voltage : 0.6/1 kV

TEST AT WORKS for ABC cables

  Routine Tests

 - Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag. 15.1 & 15.2

 - Spark Test for conductors

Liban Cables will carry out these tests on all the lengths and tests certificates will be provided.

 

Sample Tests

 - Check of the build - up and color coding of the cable

 - Check of dimensions: Insulation: according to IEC 60502-1 Parag.  16.5.2

 - Hot Set Test: according to IEC 60502-1 Parag.  16.9

 These tests will be carried out on one length during  of each size during each inspection .

Tests certificates will be provided by Liban Cables

                                                                       

Type Tests

Mechanical characteristics on insulation material (tensile strength and elongation at break) in accordance with IEC 60502-1.

These tests will be carried out on one length of the order

Tests certificates will be provided by Liban Cables

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Class 2 IEC 60228
Conductor material
Aluminum
Conductor shape
Circular
Insulation
XLPE
Messenger
Aluminium alloy
Colour
Black

Dimensional characteristics

Dimensional characteristics

Messenger cross-section
70 mm²

Electrical characteristics

Electrical characteristics

Resistance of neutral conductor at 20ºC
0.5 Ohm/km
Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close