Single core AWA Armored, XLPE insulated, PVC sheathed

Products

EXW 1*10

Nexans ref. EXW 000408 - Country ref. EXW 1*10

  • Conductor cross-section: 10 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.7 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal overall diameter: 13.0 mm
  • Approximate weight: 261 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 80 A
  • Permissible current rating when buried: 91 A

 

EXW 1*1000

Nexans ref. EXW 001713 - Country ref. EXW 1*1000

  • Conductor cross-section: 1000 mm²
  • Nominal insulation thickness: 2.8 mm
  • Nominal armour wire diameter: 2.5 mm
  • Nominal outer sheath thickness: 2.7 mm
  • Nominal overall diameter: 59.0 mm
  • Approximate weight: 10980 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0176 Ohm/km
  • Permissible current rating in open air: 1250 A
  • Permissible current rating when buried: 1115 A

 

EXW 1*120

Nexans ref. EXW 000631 - Country ref. EXW 1*120

  • Conductor cross-section: 120 mm²
  • Nominal insulation thickness: 1.2 mm
  • Nominal armour wire diameter: 1.7 mm
  • Nominal outer sheath thickness: 1.7 mm
  • Nominal overall diameter: 23.0 mm
  • Approximate weight: 1475 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating in open air: 379 A
  • Permissible current rating when buried: 363 A

 

EXW 1*150

Nexans ref. EXW 000641 - Country ref. EXW 1*150

  • Conductor cross-section: 150 mm²
  • Nominal insulation thickness: 1.4 mm
  • Nominal armour wire diameter: 1.7 mm
  • Nominal outer sheath thickness: 1.7 mm
  • Nominal overall diameter: 25.0 mm
  • Approximate weight: 1767 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating in open air: 435 A
  • Permissible current rating when buried: 405 A

 

EXW 1*16

Nexans ref. EXW 000413 - Country ref. EXW 1*16

  • Conductor cross-section: 16 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.7 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal overall diameter: 13.5 mm
  • Approximate weight: 332 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 107 A
  • Permissible current rating when buried: 118 A

 

EXW 1*185

Nexans ref. EXW 000651 - Country ref. EXW 1*185

  • Conductor cross-section: 185 mm²
  • Nominal insulation thickness: 1.6 mm
  • Nominal armour wire diameter: 1.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal overall diameter: 27.0 mm
  • Approximate weight: 2160 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
  • Permissible current rating in open air: 496 A
  • Permissible current rating when buried: 457 A

 

EXW 1*2.5

Nexans ref. EXW 001303 - Country ref. EXW 1*2.5

  • Conductor cross-section: 2.5 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.7 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal overall diameter: 11.0 mm
  • Approximate weight: 155 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: - A

 

EXW 1*240

Nexans ref. EXW 000661 - Country ref. EXW 1*240

  • Conductor cross-section: 240 mm²
  • Nominal insulation thickness: 1.6 mm
  • Nominal armour wire diameter: 1.7 mm
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal overall diameter: 30.0 mm
  • Approximate weight: 2715 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
  • Permissible current rating in open air: 584 A
  • Permissible current rating when buried: 529 A

 

EXW 1*25

Nexans ref. EXW 000414 - Country ref. EXW 1*25

  • Conductor cross-section: 25 mm²
  • Nominal insulation thickness: 0.9 mm
  • Nominal armour wire diameter: 1.7 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal overall diameter: 15.0 mm
  • Approximate weight: 450 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 142 A
  • Permissible current rating when buried: 148 A

 

EXW 1*300

Nexans ref. EXW 000671 - Country ref. EXW 1*300

  • Conductor cross-section: 300 mm²
  • Nominal insulation thickness: 1.8 mm
  • Nominal armour wire diameter: 1.7 mm
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal overall diameter: 32.0 mm
  • Approximate weight: 3322 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
  • Permissible current rating in open air: 665 A
  • Permissible current rating when buried: 600 A

 

EXW 1*35

Nexans ref. EXW 000419 - Country ref. EXW 1*35

  • Conductor cross-section: 35 mm²
  • Nominal insulation thickness: 0.9 mm
  • Nominal armour wire diameter: 1.7 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal overall diameter: 16.0 mm
  • Approximate weight: 554 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 175 A
  • Permissible current rating when buried: 179 A

 

EXW 1*4

Nexans ref. EXW 001002 - Country ref. EXW 1*4

  • Conductor cross-section: 4 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.7 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal overall diameter: 11.5 mm
  • Approximate weight: 179 kg/km
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 45 A
  • Permissible current rating when buried: - A

 

EXW 1*400

Nexans ref. EXW 000678 - Country ref. EXW 1*400

  • Conductor cross-section: 400 mm²
  • Nominal insulation thickness: 2.0 mm
  • Nominal armour wire diameter: 2 mm
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal overall diameter: 37.0 mm
  • Approximate weight: 4266 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
  • Permissible current rating in open air: 779 A
  • Permissible current rating when buried: 690 A

 

EXW 1*50

Nexans ref. EXW 000421 - Country ref. EXW 1*50

  • Conductor cross-section: 50 mm²
  • Nominal insulation thickness: 1.0 mm
  • Nominal armour wire diameter: 1.7 mm
  • Nominal outer sheath thickness: 1.5 mm
  • Nominal overall diameter: 18.0 mm
  • Approximate weight: 710 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 212 A
  • Permissible current rating when buried: 214 A

 

EXW 1*500

Nexans ref. EXW 000684 - Country ref. EXW 1*500

  • Conductor cross-section: 500 mm²
  • Nominal insulation thickness: 2.0 mm
  • Nominal armour wire diameter: 2.2 mm
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal overall diameter: 41.0 mm
  • Approximate weight: 5355 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0366 Ohm/km
  • Permissible current rating in open air: 870 A
  • Permissible current rating when buried: 780 A

 

EXW 1*6

Nexans ref. EXW 001006 - Country ref. EXW 1*6

  • Conductor cross-section: 6 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.7 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal overall diameter: 12.0 mm
  • Approximate weight: 209 kg/km
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 58 A
  • Permissible current rating when buried: 68 A

 

EXW 1*630

Nexans ref. EXW 000691 - Country ref. EXW 1*630

  • Conductor cross-section: 630 mm²
  • Nominal insulation thickness: 2.4 mm
  • Nominal armour wire diameter: 2 mm
  • Nominal outer sheath thickness: 2.3 mm
  • Nominal overall diameter: 45.0 mm
  • Approximate weight: 6825 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0283 Ohm/km
  • Permissible current rating in open air: 995 A
  • Permissible current rating when buried: 880 A

 

EXW 1*70

Nexans ref. EXW 000611 - Country ref. EXW 1*70

  • Conductor cross-section: 70 mm²
  • Nominal insulation thickness: 1.1 mm
  • Nominal armour wire diameter: 1.7 mm
  • Nominal outer sheath thickness: 1.6 mm
  • Nominal overall diameter: 19.5 mm
  • Approximate weight: 933 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 270 A
  • Permissible current rating when buried: 264 A

 

EXW 1*800

Nexans ref. EXW 000703 - Country ref. EXW 1*800

  • Conductor cross-section: 800 mm²
  • Nominal insulation thickness: 2.6 mm
  • Nominal armour wire diameter: 2.5 mm
  • Nominal outer sheath thickness: 2.5 mm
  • Nominal overall diameter: 53.0 mm
  • Approximate weight: 8981 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0221 Ohm/km
  • Permissible current rating in open air: 1145 A
  • Permissible current rating when buried: 990 A

 

EXW 1*95

Nexans ref. EXW 000615 - Country ref. EXW 1*95

  • Conductor cross-section: 95 mm²
  • Nominal insulation thickness: 1.1 mm
  • Nominal armour wire diameter: 1.7 mm
  • Nominal outer sheath thickness: 1.6 mm
  • Nominal overall diameter: 21.0 mm
  • Approximate weight: 1200 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 327 A
  • Permissible current rating when buried: 317 A

 

Description

Description

Standards

  • International
    IEC 60228; IEC 60332-1-2; IEC 60502-1

1. SCOPE

This specification covers PVC, circular, single core armoured cables, rated at 0.6/1 KV according to IEC 60502-1 for use indoors, outdoors, in cable ducts and for direct burial underground, where severe mechanical stresses are present.

2. CONSTRUCTION

2.1 Conductor

Plain, annealed electrolytic copper  conductors, circular stranded, conforming to the applicable requirements of IEC 60228.

2.2 Insulation

XLPE insulation, conforming to the applicable requirements of IEC 60502-1.

2.3 Armour

Aluminum wires armor, complying to the applicable requirements of IEC 60502-1.

2.5 Sheath

PVC based thermoplastic material, conforming to the applicable requirements of IEC 60502-1.

2.6 TESTS

Conforming to the applicable requirements of IEC 60502-1 either on Raw materials or on finished products.

TEST AT WORKS according to IEC 60502-1 armored

 Routine Tests                                                              

- Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag. 15.1 & 15.2  

- Voltage test acc. to IEC 60502-1  parag. 15.1 & 15.3 

                                                                       

Liban Cables will carry out these tests on all the lengths and tests certificates will be provided. 

                                                                       

Sample Tests                                                              

            - Check of the build - up and color coding of the cable 

            - Check of dimensions 

                        Insulation:         according to IEC 60502-1                       Parag.  16.5.2

                        Armour:             according to IEC 60502-1                       Parag.  16.7

                        Oversheath:      according to IEC 60502-1                       Parag.  16.5.3

                                                                       

These tests will be carried out on one length of each size during each inspection . 

Tests certificates will be provided by Liban Cables 

                                                                       

Type Tests                                                                  

Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-1.  

These tests will be carried out on one length of the order . 

Tests certificates will be provided by Liban Cables

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Stranded class 2
Conductor material
Copper
Conductor shape
Circular
Number of conductors
1
Insulation
XLPE
Armour type
Aluminium Wire
Outer sheath
PVC

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV
Test voltage
3500 V

Usage characteristics

Usage characteristics

Flame retardant
IEC 60332-1-2

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close