Single core AWA Armored, XLPE insulated, PVC sheathed UV resistant
Single core AWA Armored, XLPE insulated, PVC sheathed UV resistant
0.6 / 1 KV POWER CABLES Conforming to IEC 60502-1
Read moreEXW 1*300 NEW
Nexans ref. EXW 000530 - Country ref. EXW 1*300//UV
- Conductor cross-section: 300 mm²
- Nominal insulation thickness: 1.8 mm
- Nominal armour wire diameter: 1.7 mm
- Nominal outer sheath thickness: 2.0 mm
- Approximate weight: 3322 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
- Permissible current rating in open air: 665 A
- Permissible current rating when buried: 600 A
EXW 1*630//UV NEW
Nexans ref. EXW 001691 - Country ref. EXW 1*630//UV
- Conductor cross-section: 630 mm²
- Nominal insulation thickness: 2.0 mm
- Nominal armour wire diameter: 2.4 mm
- Nominal outer sheath thickness: 2.3 mm
- Approximate weight: 6826 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0283 Ohm/km
- Permissible current rating in open air: 995 A
- Permissible current rating when buried: 880 A
Description
Description
Standards
-
InternationalIEC 60228; IEC 60332-1-2; IEC 60502-1
1. SCOPE
This specification covers PVC, circular, single core armoured cables, rated at 0.6/1 KV according to IEC 60502-1 for use indoors, outdoors, in cable ducts and for direct burial underground, where severe mechanical stresses are present.
2. CONSTRUCTION
2.1 Conductor
Plain, annealed electrolytic copper conductors, circular stranded, conforming to the applicable requirements of IEC 60228.
2.2 Insulation
XLPE insulation, conforming to the applicable requirements of IEC 60502-1.
2.3 Armour
Aluminum wires armor, complying to the applicable requirements of IEC 60502-1.
2.5 Sheath
PVC based thermoplastic material, conforming to the applicable requirements of IEC 60502-1.
2.6 TESTS
Conforming to the applicable requirements of IEC 60502-1 either on Raw materials or on finished products.
TEST AT WORKS according to IEC 60502-1 armored
Routine Tests
- Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag. 15.1 & 15.2
- Voltage test acc. to IEC 60502-1 parag. 15.1 & 15.3
Liban Cables will carry out these tests on all the lengths and tests certificates will be provided.
Sample Tests
- Check of the build - up and color coding of the cable
- Check of dimensions
Insulation: according to IEC 60502-1 Parag. 16.5.2
Armour: according to IEC 60502-1 Parag. 16.7
Oversheath: according to IEC 60502-1 Parag. 16.5.3
These tests will be carried out on one length of each size during each inspection .
Tests certificates will be provided by Liban Cables
Type Tests
Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-1.
These tests will be carried out on one length of the order .
Tests certificates will be provided by Liban Cables
DRAWING SINGLE CORE, AWA ARMORED CABLE
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania