Unarmored, Flexible single core XLPE insulation, PVC sheathed
Unarmored, Flexible single core XLPE insulation, PVC sheathed
0.6 / 1 KV POWER CABLES Conforming to IEC 60502-1
Read moreF5XY 1*120 NEW
Nexans ref. F5XY 000080 - Country ref. F5XY 1*120
- Conductor cross-section: 120 mm²
- Nominal insulation thickness: 1.2 mm
- Nominal outer sheath thickness: 1.5 mm
- Nominal outer diameter: 21.0 mm
- Approximate weight: 1169 kg/km
- Max. DC resistance of the conductor at 20°C: 0.161 Ohm/km
- Permissible current rating in open air: 379 A
- Permissible current rating when buried: 363 A
F5XY 1*150 NEW
Nexans ref. F5XY 000145 - Country ref. F5XY 1*150
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 1.4 mm
- Nominal outer sheath thickness: 1.6 mm
- Nominal outer diameter: 21.0 mm
- Approximate weight: 1441 kg/km
- Max. DC resistance of the conductor at 20°C: 0.129 Ohm/km
- Permissible current rating in open air: 435 A
- Permissible current rating when buried: 405 A
F5XY 1*185 NEW
Nexans ref. F5XY 000089 - Country ref. F5XY 1*185
- Conductor cross-section: 185 mm²
- Nominal insulation thickness: 1.6 mm
- Nominal outer sheath thickness: 1.6 mm
- Nominal outer diameter: 25.0 mm
- Approximate weight: 1796 kg/km
- Max. DC resistance of the conductor at 20°C: 0.106 Ohm/km
- Permissible current rating in open air: 496 A
- Permissible current rating when buried: 457 A
F5XY 1*240 NEW
Nexans ref. F5XY 000090 - Country ref. F5XY 1*240
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 1.7 mm
- Nominal outer sheath thickness: 1.7 mm
- Nominal outer diameter: 27.0 mm
- Approximate weight: 2314 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0801 Ohm/km
- Permissible current rating in open air: 584 A
- Permissible current rating when buried: 529 A
F5XY 1*25 NEW
Nexans ref. F5XY 001025 - Country ref. F5XY 1*25
- Conductor cross-section: 25 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 11.0 mm
- Approximate weight: 283 kg/km
- Max. DC resistance of the conductor at 20°C: 0.78 Ohm/km
- Permissible current rating in open air: 142 A
- Permissible current rating when buried: 148 A
F5XY 1*300 NEW
Nexans ref. F5XY 000095 - Country ref. F5XY 1*300
- Conductor cross-section: 300 mm²
- Nominal insulation thickness: 1.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 32.0 mm
- Approximate weight: 2959 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0641 Ohm/km
- Permissible current rating in open air: 665 A
- Permissible current rating when buried: 600 A
F5XY 1*35 NEW
Nexans ref. F5XY 000321 - Country ref. F5XY 1*35
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 12.5 mm
- Approximate weight: 374 kg/km
- Max. DC resistance of the conductor at 20°C: 0.554 Ohm/km
- Permissible current rating in open air: 175 A
- Permissible current rating when buried: 179 A
F5XY 1*50
Nexans ref. F5XY 001026 - Country ref. F5XY 1*50
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 13.5 mm
- Approximate weight: 523 kg/km
- Max. DC resistance of the conductor at 20°C: 0.386 Ohm/km
- Permissible current rating in open air: 212 A
- Permissible current rating when buried: 214 A
F5XY 1*500
Nexans ref. F5XY 005570 - Country ref. F5XY 1*500
- Conductor cross-section: 500 mm²
- Nominal insulation thickness: 2.2 mm
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 41.0 mm
- Approximate weight: 4874 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0384 Ohm/km
- Permissible current rating in open air: 870 A
- Permissible current rating when buried: 780 A
F5XY 1*630 NEW
Nexans ref. F5XY 000099 - Country ref. F5XY 1*630
- Conductor cross-section: 630 mm²
- Nominal insulation thickness: 2.4 mm
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 49.0 mm
- Approximate weight: 6058 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0287 Ohm/km
- Permissible current rating in open air: 995 A
- Permissible current rating when buried: 880 A
F5XY 1*70
Nexans ref. F5XY 000070 - Country ref. F5XY 1*70
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 15.5 mm
- Approximate weight: 718 kg/km
- Max. DC resistance of the conductor at 20°C: 0.272 Ohm/km
- Permissible current rating in open air: 270 A
- Permissible current rating when buried: 264 A
F5XY 1*95 NEW
Nexans ref. F5XY 000075 - Country ref. F5XY 1*95
- Conductor cross-section: 95 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal outer sheath thickness: 1.5 mm
- Nominal outer diameter: 18.0 mm
- Approximate weight: 930 kg/km
- Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
- Permissible current rating in open air: 327 A
- Permissible current rating when buried: 317 A
Description
Description
Standards
-
InternationalIEC 60228; IEC 60332-1-2; IEC 60502-1
1. SCOPE
This specification covers XLPE insulated, circular , Single core unarmoured cables, rated at 0.6/1 KV according to IEC 60502-1.
2. CONSTRUCTION
2.1 Conductor
Plain, annealed copper conductors, circular flexible conductor, conforming to the applicable requirements of IEC 60228 class 5.
2.2 Insulation
XLPE, conforming to the applicable requirements of IEC 60502-1.
2.3 Sheath
PVC based thermoplastic material, conforming to the applicable requirements of IEC 60502-1.
2.4 TESTS
Conforming to the applicable requirements of IEC 60502-1 either on Raw materials or on finished products.
TEST AT WORKS unarmored single core
Routine Tests
- Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag. 15.1 & 15.2
- Spark test during insulation
Liban Cables will carry out these tests on all the length and tests certificates will be provided.
Sample Tests
- Check of the build - up and color coding of the cable
- Check of dimensions
Insulation : according to IEC 60502-1 Parag. 16.5.2
Oversheath : according to IEC 60502-1 Parag. 16.5.3
These tests will be carried out on one length during of each size during each inspection .
Tests certificates will be provided by Liban Cables
Type Tests
Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-1.
These tests will be carried out on one length of the order.
Tests certificates will be provided by Liban Cables
DRAWING FLEXIBLE 1C
Cable identification - LV cables ≤ 1KV
INSULATION COLORS:
|
Neutral |
Cond.1 |
Cond.2 |
Cond.3 |
Cond.4 |
1 Conductor |
|
BLACK |
|
|
|
2 Conductors |
GREY |
BLACK |
|
|
|
3 Conductors |
|
BLACK |
RED |
BLUE |
|
4 Conductors |
GREY |
BLACK |
RED |
BLUE |
|
5 Conductors |
GREY |
BLACK |
RED |
BLUE |
GREEN |
All numbered control cables (6 conductors and above), are insulated with white color, and numbered with black digits
CABLE MARKING OVER THE OUTER JACKET (by inkjet printing):
LIBAN CABLES DESCRIPTION RATED VOLTAGE SECTION MM2 Year of manufacture meter marking
Other cable identification requirements are available upon request
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania