(F)A2XS(FL)2Y 110kV

Products

(F)A2XS(FL)2Y 1*240/95 110kV

Nexans ref. H9A4DP 008570 - Country ref. H9A4DP 1*240/95(S)//NE-POL

  • Conductor diameter: 17.9 mm
  • Nominal insulation thickness: 15.0 mm
  • Nominal outer diameter: 68.0 mm
  • Rated Voltage Uo/U (Um): 87/150 (170) kV

 

(F)A2XS(FL)2Y 1*240/95 110kV

Nexans ref. H9A4DP 008571 - Country ref. H9A4DP 1*240/95(S)//NE-POL,

  • Conductor diameter: 17.9 mm
  • Nominal insulation thickness: 15.0 mm
  • Nominal outer diameter: 68.0 mm
  • Rated Voltage Uo/U (Um): 87/150 (170) kV

 

(F)A2XS(FL)2Y 1*240/95 110kV

Nexans ref. H9A4DP 168576 - Country ref. H9A4DP 1*240/95(S)//NE-POL5

  • Conductor diameter: 18.1 mm
  • Nominal insulation thickness: 15.0 mm
  • Nominal outer diameter: 68.0 mm
  • Rated Voltage Uo/U (Um): 64 / 110 (123) KV

 

(F)A2XS(FL)2Y 1*240/95 110kV 1318m/drum

Nexans ref. H9A4DP 168579 - Country ref. H9A4DP 1*240/95(S)//NE-POL-3

  • Conductor diameter: 18.1 mm
  • Nominal insulation thickness: 15.5 mm
  • Nominal outer diameter: 69.0 mm
  • Rated Voltage Uo/U (Um): 87/150 (170) kV

 

(F)A2XS(FL)2Y 1*240/95 110kV 800m/drum

Nexans ref. H9A4DP 068570 - Country ref. H9A4DP 1*240/95(S)//NE-POL1

  • Conductor diameter: 17.9 mm
  • Nominal insulation thickness: 15.0 mm
  • Nominal outer diameter: 68.0 mm
  • Rated Voltage Uo/U (Um): 87/150 (170) kV

 

Description

Description

Standards

  • International
    IEC 60840

DESCRIPTION: AL+SWEL/SC/XLPE/SC/SC SWEL/CU WIRES/SWEL/ALLUPE/PE

OPIS: AL+SWEL/S.C/XLPE/S.C/S.C. Włóknina. pęczn./druty CU/Włóknina.pęczn./ALUCOPO/PE

1. Conductor / żyła:

Aluminium stranded class 2 acc. To IEC 60228 / aluminiowa wielodrutowa klasa 2 zgodnie z IEC 60228

2. Water proof tape / taśma zapewniająca wodoszczelność:

Semi-conductor swelling tape / półprzewodząca włóknina pęczniejąca

3. Conductor screen / ekran żyły:

Extruded semi-conductor bonded to the XLPE insulation / wytłoczony półprzewodzący zespojony z izolacją z XLPE

4. Insulation / izolacja:

XLPE / XLPE

5. Insulation screen / ekran izolacji:

Extruded semi-conductor bonded to the XLPE insulation / wytłoczony półprzewodzący zespojony z izolacją z XLPE

6. Water proof tape / taśma zapewniająca wodoszczelność:

Semi-conductor swelling tape / półprzewodząca włóknina pęczniejąca

7. Screen / ekran:

Copper wires / druty miedziane

8. Water proof tape / taśma zapewniająca wodoszczelność:

Swelling tape / włóknina pęczniejąca

9. Radial water proof barrier / poprzeczna bariera wodoszczelna:

Longitudinal aluminium PE coated tape / wzdłużna taśma powlekana AL/PE

10. Oversheath / powłoka zewnętrzna:

PE / PE

TEST AT WORKS HV CABLES / PRÓBY FABRYCZNE

Routine Tests / Badania rutynowe:

 -          Max. partial discharge test  at 1.5 Uo acc. to IEC 60840  parag.9.2 / Badanie maksymalnych wyładowań niezupełnych przy 1,5 Uo zgodnie z IEC 60840 pkt 9.2

 -          High voltage test acc. to IEC 60840  parag. 9.3 / Próba wysokim napięciem zgodnie z IEC 60840 pkt 9.3

 

Liban Cables will carry out these tests on all the lengths and tests certificates will be provided / Firma Liban Cables przeprowadzi te badania dla wszystkich odcinków kabli i dostarczy świadectwa z badań

 

Sample tests / Badania próbek:

 -          Conductor examination  acc. to IEC 60840 parag. 10.4 / Badanie dyrygenta IEC 60840 pkt 10.4

 -          Max. DC resistance of conductor acc. to IEC 60840 parag. 10.5 / Maks. rezystancja DC żył  i IEC 60840 pkt 10.5

 -          Check of dimensions / Sprawdzenie wymiarów

                        Insulation / Izolacja   :  according to IEC 60840 / zgodnie z IEC 60840          Parag.  10.6.2 / pkt 10.6.2

                        Metallic screen / Ekran metaliczny  :  according to IEC 60840 / zgodnie z IEC 60840    Parag.  10.7  / pkt 10.7

                        Oversheath / Powłoka zewnętrzna : according to IEC 60840 / zgodnie z IEC 60840   Parag.  10.6.3 / pkt 10.6.3

 -          Hot set test for insulation XLPE acc. to IEC 60840 parag. 10.9 /-Badanie stopnia usieciowania izolacji z XLPE zgodnie z IEC 60840 pkt 10.9

 -          Measurement of capacitance acc. to IEC 60840 parag. 10.10 / Pomiar pojemności zgodnie z IEC 60840 pkt 10.10

 

These tests will be carried out on one length of each size during each inspection / Badania te – podczas każdej kontroli – zostaną przeprowadzone na jednym odcinku dla każdego rozmiaru kabla.

Tests certificates will be provided by Liban Cables / Świadectwa z badań dostarczy firma Liban Cables.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Number of conductors
1
Conductor material
Aluminum
Conductor shape
Round compacted
Material of the inner semi-conductor
Semi-conducting compound
Insulation
XLPE
Material of the external semi-conductor
Extruded fully bonded
Material used for longitudinal water tightness
Swellable tape
Concentric conductor
Copper wires and helical copper tape
Sheath colour
Black

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
240 mm²
Screen section
95 mm²
Nominal outer sheath thickness
3.2 mm

Electrical characteristics

Electrical characteristics

Test voltage
160 kV
Frequence
50 Hz

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Good

Usage characteristics

Usage characteristics

Bending factor when laying
30 (xD)
Laying depth, center of system
1300 mm
Ambient ground temperature
20 °C
Max. conductor temperature in service
90 °C
Short-circuit max. conductor temperature
250 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close