NA2XS(FL)2Y 110kV

Products

A2XS(FL)2Y 1*1000/190 64/110kV

Nexans ref. H9MA4DP001431 - Country ref. H9MA4DP 1*1000/190(FL)//FRA

  • Packaging: Bag (Day)
  • Conductor shape: Segmental
  • Conductor cross-section: 1000 mm²
  • Nominal insulation thickness: 13.5 mm
  • Screen section: 190 mm²
  • Nominal outer sheath thickness: 3.8 mm
  • Nominal outer diameter: 90.0 mm
  • Laying depth, center of system: 1300 mm

 

A2XS(FL)2Y 1*1000/95 64/110kV

Nexans ref. H9MA4DP001432 - Country ref. H9MA4DP 1*1000/95(FL)//FRA

  • Packaging: Bag (Day)
  • Conductor shape: Segmental
  • Conductor cross-section: 1000 mm²
  • Nominal insulation thickness: 13.5 mm
  • Screen section: 95 mm²
  • Nominal outer sheath thickness: 3.8 mm
  • Nominal outer diameter: 90.0 mm
  • Laying depth, center of system: 1300 mm

 

NA2XS(FL)2Y 1*185/50 64/110kV

Nexans ref. H9A4DP 000486 - Country ref. H9A4DP 1*185/50(FL)//POL-1,

  • Conductor shape: Round compacted
  • Conductor cross-section: 185 mm²
  • Nominal insulation thickness: 16.0 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 3.1 mm
  • Nominal outer diameter: 66.0 mm
  • Laying depth, center of system: 1300 mm

 

NA2XS(FL)2Y 1*240/90 64/110kV

Nexans ref. H9A4DP 000251 - Country ref. H9A4DP 1*240/90(FL)//POL-1

  • Packaging: Drum (Day)
  • Conductor shape: Round compacted
  • Conductor cross-section: 300 mm²
  • Nominal insulation thickness: 15.0 mm
  • Screen section: 90 mm²
  • Nominal outer sheath thickness: 3.2 mm
  • Nominal outer diameter: 66.0 mm
  • Laying depth, center of system: 1300 mm

 

NA2XS(FL)2Y 1*300/101 64/110kV

Nexans ref. H9A4DP 001898 - Country ref. H9A4DP 1*300/101(FL)//POL

  • Conductor shape: Round compacted
  • Conductor cross-section: 300 mm²
  • Nominal insulation thickness: 15.0 mm
  • Screen section: 101 mm²
  • Nominal outer sheath thickness: 3.3 mm
  • Nominal outer diameter: 69.0 mm
  • Laying depth, center of system: 1200 mm

 

NA2XS(FL)2Y 1*300/95 64/110kV

Nexans ref. H9A4DP 001727 - Country ref. H9A4DP 1*300/95(FL)//POL

  • Conductor shape: Round compacted
  • Conductor cross-section: 300 mm²
  • Nominal insulation thickness: 15.0 mm
  • Screen section: 95 mm²
  • Nominal outer sheath thickness: 3.3 mm
  • Nominal outer diameter: 69.0 mm
  • Laying depth, center of system: 1300 mm

 

NA2XS(FL)2Y 1*400/50 64/110kV

Nexans ref. H9A4DP 010047 - Country ref. H9A4DP 1*400/50(FL)//POL-1

  • Conductor shape: Round compacted
  • Conductor cross-section: 400 mm²
  • Nominal insulation thickness: 14.5 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 3.3 mm
  • Nominal outer diameter: 70.0 mm
  • Laying depth, center of system: 1300 mm

 

NA2XS(FL)2Y 1*500/110 64/110kV

Nexans ref. H9A4DP 010996 - Country ref. H9A4DP 1*500/110(FL)//POL-1

  • Conductor shape: Round compacted
  • Conductor cross-section: 500 mm²
  • Nominal insulation thickness: 14.0 mm
  • Screen section: 110 mm²
  • Nominal outer sheath thickness: 3.3 mm
  • Nominal outer diameter: 73.0 mm
  • Laying depth, center of system: 1300 mm

 

NA2XS(FL)2Y 1*500/95 64/110kV

Nexans ref. H9A4DP 012996 - Country ref. H9A4DP 1*500/95(FL)//POL-1

  • Conductor shape: Round compacted
  • Conductor cross-section: 500 mm²
  • Nominal insulation thickness: 14.0 mm
  • Screen section: 95 mm²
  • Nominal outer sheath thickness: 3.3 mm
  • Nominal outer diameter: 73.0 mm
  • Laying depth, center of system: 1300 mm

 

Description

Description

Standards

  • International
    IEC 60840

AL/S.C/XLPE/S.C/S.C Swell. tape/Cu wires+OPEN HELIX COPPER TAPE/Swell. tape/Alucopo/PE

APPLICATION

Application in ground, outdoors, in tubes, indoors and in cable ducts.

 

All high voltage cables are manufactured on the basis of specifications and can be adapted to the requirements of the customer. Therefore, all technical information are purely for information purposes and the electrical characteristics are calculated for values which are specified in the data sheets. For your specific requirements and laying arrangements please don't hesitate to contact us.

 

DESCRIPTION

Stranded Aluminum conductor according to IEC 60228, semi conducting conductor screen, insulation of cross-linked polyethylene (XLPE), semi conducting insulation screen, semi conducting swellable tape bedding, copper screen, swellable tape bedding, aluminium tape bonded to PE sheath.

TEST AT WORKS HV CABLES

Routine Tests

 -          Max. partial discharge test  at 1.5 Uo acc. to IEC 60840  parag.9.2

 -          High voltage test acc. to IEC 60840  parag. 9.3

 

Liban Cables will carry out these tests on all the lengths and tests certificates will be provided

 

Sample tests

 -          Conductor examination  acc. to IEC 60840 parag. 10.4

 -          Max. DC resistance of conductor acc. to IEC 60840 parag. 10.5

 -          Check of thicknesses

                        Insulation          :           according to IEC 60840              Parag.  10.6.2

                        Metallic screen  :           according to IEC 60840              Parag.  10.7

                        Oversheath       :           according to IEC 60840              Parag.  10.6.3

 -          Hot set test for insulation acc. to IEC 60840 parag. 10.9

 -          Measurement of capacitance acc. to IEC 60840 parag. 10.10

 

These tests will be carried out on one length of each size during each inspection .

Tests certificates will be provided by Liban Cables

DRAWING HV AL

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Material of the inner semi-conductor
Semi-conducting compound
Insulation
XLPE
Material of the external semi-conductor
Extruded fully bonded
Material used for longitudinal water tightness
Swellable tape
Concentric conductor
Copper wires and helical copper tape
Sheath colour
Black

Electrical characteristics

Electrical characteristics

Test voltage
160 kV
Frequence
50 Hz

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Good

Usage characteristics

Usage characteristics

Bending factor when laying
30 (xD)
Ambient ground temperature
20 °C
Max. conductor temperature in service
90 °C
Short-circuit max. conductor temperature
250 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close