- Products
- Your Business
- Newsroom
- Tools & Resources
- About us
- CSR
- People & Careers
- Search
- Contact us
- Compare
- Sign in
CNUD 10
Nexans ref. CNUD 000201 - Country ref. CNUD 10
- Conductor cross-section: 10 mm²
- Conductor diameter: 4.05 mm
- Nominal overall diameter: 4.05 mm
- Maximum outer diameter: 4.06 mm
- Approximate weight: 91 kg/km
- Max. DC resistance of the conductor at 20°C: 1.845 Ohm/km
CNUD 10//M
Nexans ref. CNUD 000205 - Country ref. CNUD 10//M
- Conductor cross-section: 10 mm²
- Conductor diameter: 4.05 mm
- Nominal overall diameter: 4.05 mm
- Maximum outer diameter: 4.06 mm
- Approximate weight: 91 kg/km
- Max. DC resistance of the conductor at 20°C: 1.845 Ohm/km
CNUD 120//M
Nexans ref. CNUD 000960 - Country ref. CNUD 120//M
- Conductor cross-section: 120 mm²
- Conductor diameter: 14.0 mm
- Nominal overall diameter: 14.0 mm
- Maximum outer diameter: 14.03 mm
- Approximate weight: 1072 kg/km
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
CNUD 145.8
Nexans ref. CNUD 000150 - Country ref. CNUD 145.8//NFC-M
- Conductor cross-section: 145.8 mm²
- Conductor diameter: 15.7 mm
- Nominal overall diameter: 15.7 mm
- Maximum outer diameter: 16.2 mm
- Approximate weight: 1290 kg/km
- Max. DC resistance of the conductor at 20°C: 0.128 Ohm/km
CNUD 150//M
Nexans ref. CNUD 000819 - Country ref. CNUD 150//M
- Conductor cross-section: 120 mm²
- Conductor diameter: 15.7 mm
- Nominal overall diameter: 15.7 mm
- Maximum outer diameter: 15.73 mm
- Approximate weight: 1337 kg/km
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
CNUD 16
Nexans ref. CNUD 000301 - Country ref. CNUD 16
- Conductor cross-section: 16 mm²
- Conductor diameter: 5.1 mm
- Nominal overall diameter: 5.1 mm
- Maximum outer diameter: 5.11 mm
- Approximate weight: 144 kg/km
- Max. DC resistance of the conductor at 20°C: 1.153 Ohm/km
CNUD 16//M
Nexans ref. CNUD 000305 - Country ref. CNUD 16//M
- Conductor cross-section: 16 mm²
- Conductor diameter: 5.1 mm
- Nominal overall diameter: 5.1 mm
- Maximum outer diameter: 5.11 mm
- Approximate weight: 144 kg/km
- Max. DC resistance of the conductor at 20°C: 1.153 Ohm/km
CNUD 25
Nexans ref. CNUD 000401 - Country ref. CNUD 25
- Conductor cross-section: 25 mm²
- Conductor diameter: 6.42 mm
- Nominal overall diameter: 6.42 mm
- Maximum outer diameter: 6.44 mm
- Approximate weight: 228 kg/km
- Max. DC resistance of the conductor at 20°C: 0.728 Ohm/km
CNUD 25//M
Nexans ref. CNUD 000405 - Country ref. CNUD 25//M
- Conductor cross-section: 25 mm²
- Conductor diameter: 6.42 mm
- Nominal overall diameter: 6.42 mm
- Maximum outer diameter: 6.44 mm
- Approximate weight: 228 kg/km
- Max. DC resistance of the conductor at 20°C: 0.728 Ohm/km
CNUD 29.2//M
Nexans ref. CNUD 000029 - Country ref. CNUD 29.2//M
- Conductor cross-section: 29.2 mm²
- Conductor diameter: 7.0 mm
- Nominal overall diameter: 7.0 mm
- Maximum outer diameter: 7.02 mm
- Approximate weight: 258 kg/km
- Max. DC resistance of the conductor at 20°C: 0.728 Ohm/km
CNUD 35
Nexans ref. CNUD 000501 - Country ref. CNUD 35
- Conductor cross-section: 35 mm²
- Conductor diameter: 7.5 mm
- Nominal overall diameter: 7.5 mm
- Maximum outer diameter: 7.52 mm
- Approximate weight: 309 kg/km
- Max. DC resistance of the conductor at 20°C: 0.533 Ohm/km
CNUD 35//M
Nexans ref. CNUD 000505 - Country ref. CNUD 35//M
- Conductor cross-section: 35 mm²
- Conductor diameter: 7.5 mm
- Nominal overall diameter: 7.5 mm
- Maximum outer diameter: 7.52 mm
- Approximate weight: 309 kg/km
- Max. DC resistance of the conductor at 20°C: 0.533 Ohm/km
CNUD 50
Nexans ref. CNUD 000601 - Country ref. CNUD 50
- Conductor cross-section: 50 mm²
- Conductor diameter: 9.0 mm
- Nominal overall diameter: 9.0 mm
- Maximum outer diameter: 9.02 mm
- Approximate weight: 441 kg/km
- Max. DC resistance of the conductor at 20°C: 0.381 Ohm/km
CNUD 50//M
Nexans ref. CNUD 000633 - Country ref. CNUD 50//M
- Conductor cross-section: 50 mm²
- Conductor diameter: 9.0 mm
- Nominal overall diameter: 9.0 mm
- Maximum outer diameter: 9.02 mm
- Approximate weight: 441 kg/km
- Max. DC resistance of the conductor at 20°C: 0.381 Ohm/km
CNUD 522//NFC-M
Nexans ref. CNUD 000155 - Country ref. CNUD 522//NFC-M
- Conductor cross-section: 522 mm²
- Conductor diameter: 29.7 mm
- Nominal overall diameter: 29.7 mm
- Maximum outer diameter: 31.2 mm
- Approximate weight: 4870 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0297 Ohm/km
CNUD 59.7
Nexans ref. CNUD 000590 - Country ref. CNUD 59.7//NFC-M
- Conductor cross-section: 59.7 mm²
- Conductor diameter: 2.0 mm
- Nominal overall diameter: 10.1 mm
- Maximum outer diameter: 10.4 mm
- Approximate weight: 526 kg/km
- Max. DC resistance of the conductor at 20°C: 0.311 Ohm/km
CNUD 70
Nexans ref. CNUD 000701 - Country ref. CNUD 70
- Conductor cross-section: 70 mm²
- Conductor diameter: 10.7 mm
- Nominal overall diameter: 10.7 mm
- Maximum outer diameter: 10.73 mm
- Approximate weight: 624 kg/km
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
CNUD 70//M
Nexans ref. CNUD 000705 - Country ref. CNUD 70//M
- Conductor cross-section: 70 mm²
- Conductor diameter: 10.7 mm
- Nominal overall diameter: 10.7 mm
- Maximum outer diameter: 10.73 mm
- Approximate weight: 622 kg/km
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
CNUD 8D
Nexans ref. CNUD 001101 - Country ref. CNUD 8D
- Conductor cross-section: 8 mm²
- Conductor diameter: 8.0 mm
- Nominal overall diameter: 8.0 mm
- Maximum outer diameter: 8.24 mm
- Approximate weight: 1000 kg/km
- Max. DC resistance of the conductor at 20°C: - Ohm/km
CNUD 8D//M
Nexans ref. CNUD 001105 - Country ref. CNUD 8D//M
- Conductor cross-section: 8 mm²
- Conductor diameter: 8.0 mm
- Nominal overall diameter: 8.0 mm
- Maximum outer diameter: 8.24 mm
- Approximate weight: 447 kg/km
- Max. DC resistance of the conductor at 20°C: - Ohm/km
CNUD 95//M
Nexans ref. CNUD 000805 - Country ref. CNUD 95//M
- Conductor cross-section: 95 mm²
- Conductor diameter: 12.5 mm
- Nominal overall diameter: 12.5 mm
- Maximum outer diameter: 12.53 mm
- Approximate weight: 846 kg/km
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
Description
Description
Standards
-
ProductNF C34-110/3
DESCRIPTION: CU
CONDUCTOR: STRANDED HARD BARE COPPER
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania