Multicore (PN) SWA Armored, XLPE insulated, PVC sheathed
Multicore (PN) SWA Armored, XLPE insulated, PVC sheathed
0.6 / 1 KV POWER CABLES
Conforming to IEC 60502-1
EXR 2*120+50
Nexans ref. EXR 001834 - Country ref. EXR 2*120+50
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 120 mm²
- Nominal insulation thickness: 1.2 mm
- Earth conductor cross section: 50 mm²
- Insulation thickness of smaller conductor: 1.0 mm
- Nominal outer sheath thickness: 2.3 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer diameter: 41.0 mm
- Approximate weight: 4731 kg/km
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.387 Ohm/km
- Permissible current rating in open air: 339 A
- Permissible current rating when buried: 345 A
EXR 2*120+70
Nexans ref. EXR 001832 - Country ref. EXR 2*120+70
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 120 mm²
- Nominal insulation thickness: 1.2 mm
- Earth conductor cross section: 70 mm²
- Insulation thickness of smaller conductor: 1.1 mm
- Nominal outer sheath thickness: 2.3 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer diameter: 42.0 mm
- Approximate weight: 4552 kg/km
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.268 Ohm/km
- Permissible current rating in open air: 339 A
- Permissible current rating when buried: 345 A
EXR 2*16+10
Nexans ref. EXR 060100 - Country ref. EXR 2*16+10
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.7 mm
- Earth conductor cross section: 10 mm²
- Insulation thickness of smaller conductor: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer diameter: 20.0 mm
- Approximate weight: 992 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Resistance of neutral conductor at 20ºC: 1.83 Ohm/km
- Permissible current rating in open air: 96 A
- Permissible current rating when buried: 111 A
EXR 2*25+16
Nexans ref. EXR 001971 - Country ref. EXR 2*25+16
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 25 mm²
- Nominal insulation thickness: 0.9 mm
- Earth conductor cross section: 16 mm²
- Insulation thickness of smaller conductor: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 24.0 mm
- Approximate weight: 1477 kg/km
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Resistance of neutral conductor at 20ºC: 1.15 Ohm/km
- Permissible current rating in open air: 127 A
- Permissible current rating when buried: 141 A
EXR 2*35+25
Nexans ref. EXR 001837 - Country ref. EXR 2*35+25
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Earth conductor cross section: 25 mm²
- Insulation thickness of smaller conductor: 0.9 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 27.0 mm
- Approximate weight: 1874 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.727 Ohm/km
- Permissible current rating in open air: 157 A
- Permissible current rating when buried: 170 A
EXR 2*50+25
Nexans ref. EXR 001830 - Country ref. EXR 2*50+25
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Earth conductor cross section: 25 mm²
- Insulation thickness of smaller conductor: 0.9 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 29.0 mm
- Approximate weight: 2052 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.727 Ohm/km
- Permissible current rating in open air: 190 A
- Permissible current rating when buried: 204 A
EXR 2*50+35
Nexans ref. EXR 060101 - Country ref. EXR 2*50+35
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Earth conductor cross section: 35 mm²
- Insulation thickness of smaller conductor: 0.9 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 29.5 mm
- Approximate weight: 2375 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.524 Ohm/km
- Permissible current rating in open air: 190 A
- Permissible current rating when buried: 204 A
EXR 2*70+35
Nexans ref. EXR 001831 - Country ref. EXR 2*70+35
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 1.1 mm
- Earth conductor cross section: 35 mm²
- Insulation thickness of smaller conductor: 0.9 mm
- Nominal outer sheath thickness: 2.0 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer diameter: 34.0 mm
- Approximate weight: 2908 kg/km
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.524 Ohm/km
- Permissible current rating in open air: 242 A
- Permissible current rating when buried: 252 A
EXR 3*10+6
Nexans ref. EXR 004300 - Country ref. EXR 3*16+10
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 10 mm²
- Nominal insulation thickness: 0.7 mm
- Earth conductor cross section: 6 mm²
- Insulation thickness of smaller conductor: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer diameter: 19.5 mm
- Approximate weight: 899 kg/km
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Resistance of neutral conductor at 20ºC: 3.08 Ohm/km
- Permissible current rating in open air: 71 A
- Permissible current rating when buried: 88 A
EXR 3*120+70SM
Nexans ref. EXR 004392 - Country ref. EXR 3*120+70SM
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 120 mm²
- Nominal insulation thickness: 1.4 mm
- Earth conductor cross section: 70 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal outer sheath thickness: 2.4 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer diameter: 43.0 mm
- Approximate weight: 5767 kg/km
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.268 Ohm/km
- Permissible current rating in open air: 339 A
- Permissible current rating when buried: 345 A
EXR 3*150+70SM
Nexans ref. EXR 004395 - Country ref. EXR 3*150+70SM
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 1.4 mm
- Earth conductor cross section: 70 mm²
- Insulation thickness of smaller conductor: 1.1 mm
- Nominal outer sheath thickness: 2.5 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 48.0 mm
- Approximate weight: 7200 kg/km
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.268 Ohm/km
- Permissible current rating in open air: 390 A
- Permissible current rating when buried: 386 A
EXR 3*150+95SM
Nexans ref. EXR 004415 - Country ref. EXR 3*150+95SM
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 1.4 mm
- Earth conductor cross section: 95 mm²
- Insulation thickness of smaller conductor: 1.1 mm
- Nominal outer sheath thickness: 2.5 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 49.0 mm
- Approximate weight: 7481 kg/km
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.193 Ohm/km
- Permissible current rating in open air: 390 A
- Permissible current rating when buried: 386 A
EXR 3*16+10
Nexans ref. EXR 004315 - Country ref. EXR 3*16+10
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.7 mm
- Earth conductor cross section: 10 mm²
- Insulation thickness of smaller conductor: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer diameter: 22.0 mm
- Approximate weight: 1182 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Resistance of neutral conductor at 20ºC: 1.83 Ohm/km
- Permissible current rating in open air: 96 A
- Permissible current rating when buried: 111 A
EXR 3*185+95SM
Nexans ref. EXR 004445 - Country ref. EXR 3*185+95SM
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 185 mm²
- Nominal insulation thickness: 1.6 mm
- Earth conductor cross section: 95 mm²
- Insulation thickness of smaller conductor: 1.1 mm
- Nominal outer sheath thickness: 2.7 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 53.0 mm
- Approximate weight: 8784 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.193 Ohm/km
- Permissible current rating in open air: 444 A
- Permissible current rating when buried: 435 A
EXR 3*240+120 SM
Nexans ref. EXR 004455 - Country ref. EXR 3*240+120SM
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 1.7 mm
- Earth conductor cross section: 120 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal outer sheath thickness: 2.9 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 59.0 mm
- Approximate weight: 10965 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.153 Ohm/km
- Permissible current rating in open air: 522 A
- Permissible current rating when buried: 504 A
EXR 3*25+16
Nexans ref. EXR 004325 - Country ref. EXR 3*25+16
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 25 mm²
- Nominal insulation thickness: 0.9 mm
- Earth conductor cross section: 16 mm²
- Insulation thickness of smaller conductor: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 26.0 mm
- Approximate weight: 1776 kg/km
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Resistance of neutral conductor at 20ºC: 1.15 Ohm/km
- Permissible current rating in open air: 127 A
- Permissible current rating when buried: 141 A
EXR 3*300+150SM NEW
Nexans ref. EXR 004475 - Country ref. EXR 3*300+150SM
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 300 mm²
- Nominal insulation thickness: 1.8 mm
- Earth conductor cross section: 150 mm²
- Insulation thickness of smaller conductor: 1.4 mm
- Nominal outer sheath thickness: 3.0 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 64.0 mm
- Approximate weight: 13357 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.124 Ohm/km
- Permissible current rating in open air: 595 A
- Permissible current rating when buried: 571 A
EXR 3*35+16
Nexans ref. EXR 003016 - Country ref. EXR 3*35+16
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Earth conductor cross section: 16 mm²
- Insulation thickness of smaller conductor: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 28.0 mm
- Approximate weight: 2042 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Resistance of neutral conductor at 20ºC: 1.15 Ohm/km
- Permissible current rating in open air: 157 A
- Permissible current rating when buried: 170 A
EXR 3*50+25 NEW
Nexans ref. EXR 000788 - Country ref. EXR 3*50+25
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Earth conductor cross section: 25 mm²
- Insulation thickness of smaller conductor: 0.9 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 32.0 mm
- Approximate weight: 2641 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.727 Ohm/km
- Permissible current rating in open air: 190 A
- Permissible current rating when buried: 204 A
EXR 3*70+35SM/RM
Nexans ref. EXR 005117 - Country ref. EXR 3*70+35SM/RM
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 1.1 mm
- Earth conductor cross section: 35 mm²
- Insulation thickness of smaller conductor: 0.9 mm
- Nominal outer sheath thickness: 2.1 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer diameter: 35.0 mm
- Approximate weight: 3623 kg/km
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.524 Ohm/km
- Permissible current rating in open air: 242 A
- Permissible current rating when buried: 252 A
EXR 3*70+50SM/RM
Nexans ref. EXR 004368 - Country ref. EXR 3*70+50SM/RM
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 1.1 mm
- Earth conductor cross section: 50 mm²
- Insulation thickness of smaller conductor: 1.0 mm
- Nominal outer sheath thickness: 2.1 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer diameter: 36.0 mm
- Approximate weight: 3774 kg/km
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.387 Ohm/km
- Permissible current rating in open air: 242 A
- Permissible current rating when buried: 252 A
EXR 3*95+50
Nexans ref. EXR 000209 - Country ref. EXR 3*95+50SM/RM
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 95 mm²
- Nominal insulation thickness: 1.1 mm
- Earth conductor cross section: 50 mm²
- Insulation thickness of smaller conductor: 1.0 mm
- Nominal outer sheath thickness: 2.2 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer diameter: 39.0 mm
- Approximate weight: 4652 kg/km
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.387 Ohm/km
- Permissible current rating in open air: 293 A
- Permissible current rating when buried: 302 A
EXR 4*120+70
Nexans ref. EXR 001531 - Country ref. EXR 4*120+70
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 120 mm²
- Nominal insulation thickness: 1.2 mm
- Earth conductor cross section: 70 mm²
- Insulation thickness of smaller conductor: 1.1 mm
- Nominal outer sheath thickness: 2.5 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 51.5 mm
- Approximate weight: 7823 kg/km
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.268 Ohm/km
- Permissible current rating in open air: 339 A
- Permissible current rating when buried: 345 A
EXR 4*150+70
Nexans ref. EXR 004095 - Country ref. EXR 4*150+70
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 1.4 mm
- Earth conductor cross section: 70 mm²
- Insulation thickness of smaller conductor: 1.1 mm
- Nominal outer sheath thickness: 2.7 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 56.0 mm
- Approximate weight: 9080 kg/km
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.268 Ohm/km
- Permissible current rating in open air: 390 A
- Permissible current rating when buried: 386 A
EXR 4*150+95
Nexans ref. EXR 001135 - Country ref. EXR 4*150+95
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 1.4 mm
- Earth conductor cross section: 95 mm²
- Insulation thickness of smaller conductor: 1.1 mm
- Nominal outer sheath thickness: 2.7 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 56.0 mm
- Approximate weight: 9406 kg/km
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.193 Ohm/km
- Permissible current rating in open air: 390 A
- Permissible current rating when buried: 386 A
EXR 4*16+10
Nexans ref. EXR 000970 - Country ref. EXR 4*16+10
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.7 mm
- Earth conductor cross section: 10 mm²
- Insulation thickness of smaller conductor: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 24.0 mm
- Approximate weight: 1495 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Resistance of neutral conductor at 20ºC: 1.83 Ohm/km
- Permissible current rating in open air: 96 A
- Permissible current rating when buried: 111 A
EXR 4*185+95
Nexans ref. EXR 001556 - Country ref. EXR 4*185+95
- Conductor shape: Shaped
- Number of conductors: 5
- Conductor cross-section: 185 mm²
- Nominal insulation thickness: 1.6 mm
- Earth conductor cross section: 95 mm²
- Insulation thickness of smaller conductor: 1.1 mm
- Nominal outer sheath thickness: 2.9 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 62.0 mm
- Approximate weight: 11106 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.193 Ohm/km
- Permissible current rating in open air: 444 A
- Permissible current rating when buried: 435 A
EXR 4*240+120
Nexans ref. EXR 001569 - Country ref. EXR 4*240+120
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 1.7 mm
- Earth conductor cross section: 120 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal outer sheath thickness: 3.1 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer diameter: 69.0 mm
- Approximate weight: 13883 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.153 Ohm/km
- Permissible current rating in open air: 522 A
- Permissible current rating when buried: 504 A
EXR 4*25+16
Nexans ref. EXR 000971 - Country ref. EXR 4*25+16
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 25 mm²
- Nominal insulation thickness: 0.9 mm
- Earth conductor cross section: 16 mm²
- Insulation thickness of smaller conductor: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 28.0 mm
- Approximate weight: 2056 kg/km
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Resistance of neutral conductor at 20ºC: 1.15 Ohm/km
- Permissible current rating in open air: 127 A
- Permissible current rating when buried: 141 A
EXR 4*35+16
Nexans ref. EXR 001838 - Country ref. EXR 4*35+16
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Earth conductor cross section: 16 mm²
- Insulation thickness of smaller conductor: 0.7 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 31.0 mm
- Approximate weight: 2470 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Resistance of neutral conductor at 20ºC: 1.15 Ohm/km
- Permissible current rating in open air: 157 A
- Permissible current rating when buried: 170 A
EXR 4*35+25
Nexans ref. EXR 001839 - Country ref. EXR 4*35+25
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Earth conductor cross section: 25 mm²
- Insulation thickness of smaller conductor: 0.9 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer diameter: 32.0 mm
- Approximate weight: 2622 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.727 Ohm/km
- Permissible current rating in open air: 157 A
- Permissible current rating when buried: 170 A
EXR 4*50+25
Nexans ref. EXR 001840 - Country ref. EXR 4*50+25
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Earth conductor cross section: 25 mm²
- Insulation thickness of smaller conductor: 0.9 mm
- Nominal outer sheath thickness: 2.1 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer diameter: 36.0 mm
- Approximate weight: 3513 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.727 Ohm/km
- Permissible current rating in open air: 190 A
- Permissible current rating when buried: 204 A
EXR 4*50+35
Nexans ref. EXR 060102 - Country ref. EXR 4*50+35
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Earth conductor cross section: 35 mm²
- Insulation thickness of smaller conductor: 0.9 mm
- Nominal outer sheath thickness: 2.1 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer diameter: 36.5 mm
- Approximate weight: 3630 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.524 Ohm/km
- Permissible current rating in open air: 190 A
- Permissible current rating when buried: 204 A
EXR 4*70+35 NEW
Nexans ref. EXR 001842 - Country ref. EXR 4*70+35
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 1.1 mm
- Earth conductor cross section: 35 mm²
- Insulation thickness of smaller conductor: 0.9 mm
- Nominal outer sheath thickness: 2.2 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer diameter: 41.0 mm
- Approximate weight: 4565 kg/km
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.524 Ohm/km
- Permissible current rating in open air: 242 A
- Permissible current rating when buried: 252 A
EXR 4*70+50
Nexans ref. EXR 060103 - Country ref. EXR 4*70+50
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 1.1 mm
- Earth conductor cross section: 50 mm²
- Insulation thickness of smaller conductor: 1.0 mm
- Nominal outer sheath thickness: 2.2 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer diameter: 41.0 mm
- Approximate weight: 4772 kg/km
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.387 Ohm/km
- Permissible current rating in open air: 242 A
- Permissible current rating when buried: 252 A
EXR 4*95+50 NEW
Nexans ref. EXR 000967 - Country ref. EXR 4*95+50
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 95 mm²
- Nominal insulation thickness: 1.1 mm
- Earth conductor cross section: 50 mm²
- Insulation thickness of smaller conductor: 1.0 mm
- Nominal outer sheath thickness: 2.4 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer diameter: 46.0 mm
- Approximate weight: 5897 kg/km
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.387 Ohm/km
- Permissible current rating in open air: 293 A
- Permissible current rating when buried: 302 A
Description
Description
Standards
-
InternationalIEC 60228; IEC 60332-1-2; IEC 60502-1
1. SCOPE
This specification covers XLPE insulated, circular or shaped, multicore armoured cables, rated at 0.6/1 KV according to IEC 60502-1 for use indoors, outdoors, in cable ducts and for direct burial underground, where severe mechanical stresses are present.
2. CONSTRUCTION
2.1 Phase Conductor
Plain, annealed electrolytic copper conductors, circular stranded, or sectoral stranded only for 3 Cores+Eath: sizes ≥70 to ≤300, conforming to the applicable requirements of IEC 60228.
2.2 Phase Conductor Insulation
XLPE thermosetting material, conforming to the applicable requirements of IEC 60502-1.
2.3 Neutral Conductor
Plain, annealed electrolytic copper conductors, circular stranded, or sectoral stranded only for 3 Cores+Eath: sizes ≥70 to ≤300, conforming to the applicable requirements of IEC 60228.
2.4 Neutral Conductor Insulation
XLPE thermosetting material, conforming to the applicable requirements of IEC 60502-1.
2.5 Assembly
Insulated conductors are laid up, filled where necessary with non-hygroscopic material and covered with an extruded thickness of thermoplastic material.
2.6 Armour
Galvanized Steel Wires Armor complying to the applicable requirements of IEC 60502-1.
2.7 Sheath
PVC based thermoplastic material, conforming to the applicable requirements of IEC 60502-1.
2.8 TESTS
Conforming to the applicable requirements of IEC 60502-1 either on Raw materials or on finished products.
TEST AT WORKS according to IEC 60502-1 armored
Routine Tests
- Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag. 15.1 & 15.2
- Voltage test acc. to IEC 60502-1 parag. 15.1 & 15.3
Liban Cables will carry out these tests on all the lengths and tests certificates will be provided.
Sample Tests
- Check of the build - up and color coding of the cable
- Check of dimensions
Insulation: according to IEC 60502-1 Parag. 16.5.2
Armour: according to IEC 60502-1 Parag. 16.7
Oversheath: according to IEC 60502-1 Parag. 16.5.3
These tests will be carried out on one length of each size during each inspection .
Tests certificates will be provided by Liban Cables
Type Tests
Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-1.
These tests will be carried out on one length of the order .
Tests certificates will be provided by Liban Cables
Cable identification - LV cables ≤ 1KV
INSULATION COLORS:
|
Neutral |
Cond.1 |
Cond.2 |
Cond.3 |
Cond.4 |
1 Conductor |
|
BLACK |
|
|
|
2 Conductors |
GREY |
BLACK |
|
|
|
3 Conductors |
|
BLACK |
RED |
BLUE |
|
4 Conductors |
GREY |
BLACK |
RED |
BLUE |
|
5 Conductors |
GREY |
BLACK |
RED |
BLUE |
GREEN |
All numbered control cables (6 conductors and above), are insulated with white color, and numbered with black digits
CABLE MARKING OVER THE OUTER JACKET (by inkjet printing):
LIBAN CABLES DESCRIPTION RATED VOLTAGE SECTION MM2 Year of manufacture meter marking
Other cable identification requirements are available upon request
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania