Unarmored, multicore XLPE insulation, PVC sheathed

Products

EX 10*1.5 NEW

Nexans ref. EX 005653 - Country ref. EX 10*1.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 10
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: 1.5 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 15.0 mm
  • Maximum outer diameter: 16.05 mm
  • Approximate weight: 286 kg/km
  • Number of cores: 10
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 34 A

 

EX 10*2.5

Nexans ref. EX 006035 - Country ref. EX 10*2.5

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 10
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 16.5 mm
  • Maximum outer diameter: 17.66 mm
  • Approximate weight: 392 kg/km
  • Number of cores: 10
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 46 A

 

EX 10*6

Nexans ref. EX 006347 - Country ref. EX 10*6

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 10
  • Conductor cross-section: 6 mm²
  • Conductor diameter: 4.37 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 21.0 mm
  • Maximum outer diameter: 22.47 mm
  • Approximate weight: 754 kg/km
  • Number of cores: 10
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 58 A
  • Permissible current rating when buried: 74 A

 

EX 11*1.5

Nexans ref. EX 105653 - Country ref. EX 11*1.5

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 11
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 15.0 mm
  • Maximum outer diameter: 16.05 mm
  • Approximate weight: 308 kg/km
  • Number of cores: 11
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 34 A

 

EX 12*1.5

Nexans ref. EX 005629 - Country ref. EX 12*1.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 12
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 15.0 mm
  • Maximum outer diameter: 16.05 mm
  • Approximate weight: 326 kg/km
  • Number of cores: 12
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 34 A

 

EX 12*2.5

Nexans ref. EX 006038 - Country ref. EX 12*2.5

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 12
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 17.0 mm
  • Maximum outer diameter: 18.2 mm
  • Approximate weight: 451 kg/km
  • Number of cores: 12
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 46 A

 

EX 12*4

Nexans ref. EX 006345 - Country ref. EX 12*4

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 12
  • Conductor cross-section: 4 mm²
  • Conductor diameter: 2.43 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 19.5 mm
  • Maximum outer diameter: 20.6 mm
  • Approximate weight: 395 kg/km
  • Number of cores: 12
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 45 A
  • Permissible current rating when buried: 59 A

 

EX 13*1.5

Nexans ref. EX 105654 - Country ref. EX 13*1.5

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 13
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 16.0 mm
  • Maximum outer diameter: 17.2 mm
  • Approximate weight: 351 kg/km
  • Number of cores: 13
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 34 A

 

EX 15*1.5 NEW

Nexans ref. EX 003669 - Country ref. EX 15*1.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 15
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 17.0 mm
  • Maximum outer diameter: 18.19 mm
  • Approximate weight: 393 kg/km
  • Number of cores: 15
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 34 A

 

EX 15*2.5

Nexans ref. EX 006117 - Country ref. EX 15*2.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 15
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 19.0 mm
  • Maximum outer diameter: 20.33 mm
  • Approximate weight: 547 kg/km
  • Number of cores: 15
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 46 A

 

EX 16*1.5

Nexans ref. EX 001886 - Country ref. EX 16*1.5

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 16
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: 1.5 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 17.0 mm
  • Maximum outer diameter: 18.2 mm
  • Approximate weight: 418 kg/km
  • Number of cores: 16
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 34 A

 

EX 16*2.5

Nexans ref. EX 006055 - Country ref. EX 16*2.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 16
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 19.0 mm
  • Maximum outer diameter: 20.33 mm
  • Approximate weight: 578 kg/km
  • Number of cores: 16
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 46 A

 

EX 18*1.5

Nexans ref. EX 000913 - Country ref. EX 18*1.5

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 18
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 17.5 mm
  • Maximum outer diameter: 18.8 mm
  • Approximate weight: 459 kg/km
  • Number of cores: 18
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 34 A

 

EX 19*1.5 NEW

Nexans ref. EX 005641 - Country ref. EX 19*1.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 19
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: 1.48 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 18.0 mm
  • Maximum outer diameter: 19.26 mm
  • Approximate weight: 473 kg/km
  • Number of cores: 19
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 34 A

 

EX 19*2.5

Nexans ref. EX 006056 - Country ref. EX 19*2.5

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 19
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: 1.93 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 20.0 mm
  • Maximum outer diameter: 17.66 mm
  • Approximate weight: 660 kg/km
  • Number of cores: 19
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 46 A

 

EX 2*1.5

Nexans ref. EX 000330 - Country ref. EX 2*1.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 2
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 9.5 mm
  • Maximum outer diameter: 10.16 mm
  • Approximate weight: 110 kg/km
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 34 A

 

EX 2*1.5RE

Nexans ref. EX 000325 - Country ref. EX 2*1.5RE

  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Number of conductors: 2
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: 1.7 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 9.0 mm
  • Maximum outer diameter: 9.63 mm
  • Approximate weight: 106 kg/km
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 34 A

 

EX 2*10

Nexans ref. EX 000601 - Country ref. EX 2*10

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 2
  • Conductor cross-section: 10 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 14.0 mm
  • Maximum outer diameter: 14.98 mm
  • Approximate weight: 341 kg/km
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 80 A
  • Permissible current rating when buried: 101 A

 

EX 2*120

Nexans ref. EX 000865 - Country ref. EX 2*120

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 2
  • Conductor cross-section: 120 mm²
  • Conductor diameter: 12.9 mm
  • Nominal insulation thickness: 1.2 mm
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 35.0 mm
  • Maximum outer diameter: 37.45 mm
  • Approximate weight: 2994 kg/km
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating in open air: 379 A
  • Permissible current rating when buried: 397 A

 

EX 2*150

Nexans ref. EX 000870 - Country ref. EX 2*150

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 2
  • Conductor cross-section: 150 mm²
  • Conductor diameter: 14.2 mm
  • Nominal insulation thickness: 1.4 mm
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 38.0 mm
  • Maximum outer diameter: 40.7 mm
  • Approximate weight: 3702 kg/km
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating in open air: 435 A
  • Permissible current rating when buried: 444 A

 

EX 2*16

Nexans ref. EX 000701 - Country ref. EX 2*16

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 2
  • Conductor cross-section: 16 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 15.5 mm
  • Maximum outer diameter: 16.59 mm
  • Approximate weight: 481 kg/km
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 107 A
  • Permissible current rating when buried: 128 A

 

EX 2*2.5 NEW

Nexans ref. EX 000343 - Country ref. EX 2*2.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 2
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 10.0 mm
  • Maximum outer diameter: 10.7 mm
  • Approximate weight: 140 kg/km
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 46 A

 

EX 2*2.5RE

Nexans ref. EX 000335 - Country ref. EX 2*2.5RE

  • Packaging: Drum (m)
  • Conductor flexibility: Class 1 acc. to IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 2
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: 1.755 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 9.8 mm
  • Maximum outer diameter: 10.5 mm
  • Approximate weight: 141 kg/km
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 46 A

 

EX 2*25

Nexans ref. EX 000801 - Country ref. EX 2*25

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 2
  • Conductor cross-section: 25 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.9 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 18.5 mm
  • Maximum outer diameter: 19.8 mm
  • Approximate weight: 730 kg/km
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 142 A
  • Permissible current rating when buried: 162 A

 

EX 2*35

Nexans ref. EX 000811 - Country ref. EX 2*35

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 2
  • Conductor cross-section: 35 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.9 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 21.0 mm
  • Maximum outer diameter: 22.47 mm
  • Approximate weight: 953 kg/km
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 175 A
  • Permissible current rating when buried: 195 A

 

EX 2*4 NEW

Nexans ref. EX 000401 - Country ref. EX 2*4

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 2
  • Conductor cross-section: 4 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 11.0 mm
  • Maximum outer diameter: 11.77 mm
  • Approximate weight: 184 kg/km
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 45 A
  • Permissible current rating when buried: 59 A

 

EX 2*50

Nexans ref. EX 000821 - Country ref. EX 2*50

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 2
  • Conductor cross-section: 50 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.0 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 24.0 mm
  • Maximum outer diameter: 25.68 mm
  • Approximate weight: 1271 kg/km
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 212 A
  • Permissible current rating when buried: 235 A

 

EX 2*6 NEW

Nexans ref. EX 000501 - Country ref. EX 2*6

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 2
  • Conductor cross-section: 6 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 12.0 mm
  • Maximum outer diameter: 12.84 mm
  • Approximate weight: 239 kg/km
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 58 A
  • Permissible current rating when buried: 74 A

 

EX 2*6RE

Nexans ref. EX 100501 - Country ref. EX 2*6RE

  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular
  • Number of conductors: 2
  • Conductor cross-section: 6 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 11.5 mm
  • Maximum outer diameter: 12.3 mm
  • Approximate weight: 239 kg/km
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 58 A
  • Permissible current rating when buried: 74 A

 

EX 2*95

Nexans ref. EX 000839 - Country ref. EX 2*95

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 2
  • Conductor cross-section: 95 mm²
  • Conductor diameter: 11.4 mm
  • Nominal insulation thickness: 1.1 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 31.0 mm
  • Maximum outer diameter: 33.2 mm
  • Approximate weight: 1271 kg/km
  • Number of cores: 2
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 327 A
  • Permissible current rating when buried: 347 A

 

EX 20*1.5 NEW

Nexans ref. EX 005644 - Country ref. EX 20*1.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 20
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 19.0 mm
  • Maximum outer diameter: 20.33 mm
  • Approximate weight: 504 kg/km
  • Number of cores: 20
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 34 A

 

EX 24*1.5

Nexans ref. EX 005663 - Country ref. EX 24*1.5

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 24
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: 1.48 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 20.5 mm
  • Maximum outer diameter: 16.05 mm
  • Approximate weight: 588 kg/km
  • Number of cores: 24
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 34 A

 

EX 24*2.5

Nexans ref. EX 006059 - Country ref. EX 24*2.5

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 24
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: 1.93 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 23.5 mm
  • Maximum outer diameter: 25.1 mm
  • Approximate weight: 829 kg/km
  • Number of cores: 24
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 46 A

 

EX 25*1.5

Nexans ref. EX 000070 - Country ref. EX 25*1.5

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 25
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 21.0 mm
  • Maximum outer diameter: 22.47 mm
  • Approximate weight: 610 kg/km
  • Number of cores: 25
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 34 A

 

EX 27*1.5 NEW

Nexans ref. EX 005666 - Country ref. EX 27*1.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 27
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 21.0 mm
  • Maximum outer diameter: 22.47 mm
  • Approximate weight: 646 kg/km
  • Number of cores: 27
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 34 A

 

EX 3*1

Nexans ref. EX 000060 - Country ref. EX 3*1

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 3
  • Conductor cross-section: 1 mm²
  • Conductor diameter: 1.3 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 9.2 mm
  • Maximum outer diameter: 9.85 mm
  • Approximate weight: 114 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 18.1 Ohm/km
  • Permissible current rating in open air: 17 A
  • Permissible current rating when buried: 21 A

 

EX 3*1.5

Nexans ref. EX 001011 - Country ref. EX 3*1.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 3
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 10.0 mm
  • Maximum outer diameter: 10.7 mm
  • Approximate weight: 127 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 22 A
  • Permissible current rating when buried: 29 A

 

EX 3*1.5RE

Nexans ref. EX 000901 - Country ref. EX 3*1.5RE

  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Number of conductors: 3
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: 1.7 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 9.5 mm
  • Maximum outer diameter: 10.16 mm
  • Approximate weight: 124 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 22 A
  • Permissible current rating when buried: 29 A

 

EX 3*1.5RE - M

Nexans ref. EX 700901 - Country ref. EX 3*1.5RE//COIL-M

  • Packaging: Coil (100m)
  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Number of conductors: 3
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: 1.7 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 9.5 mm
  • Maximum outer diameter: 10.16 mm
  • Approximate weight: 124 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 22 A
  • Permissible current rating when buried: 29 A

 

EX 3*10

Nexans ref. EX 001401 - Country ref. EX 3*10

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 3
  • Conductor cross-section: 10 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 14.5 mm
  • Maximum outer diameter: 15.52 mm
  • Approximate weight: 431 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 71 A
  • Permissible current rating when buried: 88 A

 

EX 3*120SM

Nexans ref. EX 002101 - Country ref. EX 3*120SM

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Shaped
  • Number of conductors: 3
  • Conductor cross-section: 120 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.2 mm
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 34.0 mm
  • Maximum outer diameter: 36.38 mm
  • Approximate weight: 3757 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating in open air: 339 A
  • Permissible current rating when buried: 345 A

 

EX 3*150SM

Nexans ref. EX 002201 - Country ref. EX 3*150SM

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Shaped
  • Number of conductors: 3
  • Conductor cross-section: 150 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.4 mm
  • Nominal outer sheath thickness: 2.3 mm
  • Nominal outer diameter: 40.0 mm
  • Maximum outer diameter: 42.8 mm
  • Approximate weight: 4441 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating in open air: 390 A
  • Permissible current rating when buried: 386 A

 

EX 3*16

Nexans ref. EX 001501 - Country ref. EX 3*16

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 3
  • Conductor cross-section: 16 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 16.5 mm
  • Maximum outer diameter: 17.66 mm
  • Approximate weight: 620 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 96 A
  • Permissible current rating when buried: 111 A

 

EX 3*185SM

Nexans ref. EX 002301 - Country ref. EX 3*185SM

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Shaped
  • Number of conductors: 3
  • Conductor cross-section: 185 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.6 mm
  • Nominal outer sheath thickness: 2.4 mm
  • Nominal outer diameter: 42.0 mm
  • Maximum outer diameter: 44.94 mm
  • Approximate weight: 5452 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
  • Permissible current rating in open air: 444 A
  • Permissible current rating when buried: 435 A

 

EX 3*2.5

Nexans ref. EX 001015 - Country ref. EX 3*2.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 3
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 11.0 mm
  • Maximum outer diameter: 11.77 mm
  • Approximate weight: 166 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 30 A
  • Permissible current rating when buried: 40 A

 

EX 3*2.5RE

Nexans ref. EX 001001 - Country ref. EX 3*2.5RE

  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular
  • Number of conductors: 3
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: 1.8 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 11.0 mm
  • Maximum outer diameter: 11.77 mm
  • Approximate weight: 160 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 30 A
  • Permissible current rating when buried: 40 A

 

EX 3*2.5RE - M

Nexans ref. EX 701001 - Country ref. EX 3*2.5RE//COIL-M

  • Packaging: Coil (100m)
  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular
  • Number of conductors: 3
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: 1.8 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 11.0 mm
  • Maximum outer diameter: 11.77 mm
  • Approximate weight: 160 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 30 A
  • Permissible current rating when buried: 40 A

 

EX 3*240SM

Nexans ref. EX 002401 - Country ref. EX 3*240SM

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Shaped
  • Number of conductors: 3
  • Conductor cross-section: 240 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.7 mm
  • Nominal outer sheath thickness: 2.6 mm
  • Nominal outer diameter: 47.0 mm
  • Maximum outer diameter: 50.29 mm
  • Approximate weight: 7123 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
  • Permissible current rating in open air: 522 A
  • Permissible current rating when buried: 504 A

 

EX 3*25

Nexans ref. EX 001601 - Country ref. EX 3*25

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 3
  • Conductor cross-section: 25 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.9 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 20.0 mm
  • Maximum outer diameter: 21.4 mm
  • Approximate weight: 942 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 127 A
  • Permissible current rating when buried: 141 A

 

EX 3*300SM

Nexans ref. EX 002501 - Country ref. EX 3*300SM

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Shaped
  • Number of conductors: 3
  • Conductor cross-section: 300 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.8 mm
  • Nominal outer sheath thickness: 2.8 mm
  • Nominal outer diameter: 52.0 mm
  • Maximum outer diameter: 55.64 mm
  • Approximate weight: 8996 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
  • Permissible current rating in open air: 595 A
  • Permissible current rating when buried: 571 A

 

EX 3*35

Nexans ref. EX 001705 - Country ref. EX 3*35

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 3
  • Conductor cross-section: 35 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.9 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 22.0 mm
  • Maximum outer diameter: 23.54 mm
  • Approximate weight: 1149 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 157 A
  • Permissible current rating when buried: 170 A

 

EX 3*4

Nexans ref. EX 001201 - Country ref. EX 3*4

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 3
  • Conductor cross-section: 4 mm²
  • Conductor diameter: 2.4 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 12.0 mm
  • Maximum outer diameter: 12.84 mm
  • Approximate weight: 223 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 40 A
  • Permissible current rating when buried: 51 A

 

EX 3*400

Nexans ref. EX 004860 - Country ref. EX 3*400

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 3
  • Conductor cross-section: 400 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 2.0 mm
  • Nominal outer sheath thickness: 3.1 mm
  • Nominal outer diameter: 64.0 mm
  • Maximum outer diameter: 68.48 mm
  • Approximate weight: 11683 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
  • Permissible current rating in open air: 695 A
  • Permissible current rating when buried: 657 A

 

EX 3*4RE

Nexans ref. EX 001101 - Country ref. EX 3*4RE

  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Number of conductors: 3
  • Conductor cross-section: 4 mm²
  • Conductor diameter: 2.3 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 11.5 mm
  • Maximum outer diameter: 12.3 mm
  • Approximate weight: 224 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 40 A
  • Permissible current rating when buried: 51 A

 

EX 3*50

Nexans ref. EX 004052 - Country ref. EX 3*50

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 3
  • Conductor cross-section: 50 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.0 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 25.0 mm
  • Maximum outer diameter: 26.75 mm
  • Approximate weight: 1548 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 190 A
  • Permissible current rating when buried: 204 A

 

EX 3*500

Nexans ref. EX 001250 - Country ref. EX 3*500

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 3
  • Conductor cross-section: 500 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 2.2 mm
  • Nominal outer sheath thickness: 3.2 mm
  • Nominal outer diameter: 72.0 mm
  • Maximum outer diameter: 77.04 mm
  • Approximate weight: 14907 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 0.0366 Ohm/km
  • Permissible current rating in open air: 777 A
  • Permissible current rating when buried: 735 A

 

EX 3*6

Nexans ref. EX 001202 - Country ref. EX 3*6

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 3
  • Conductor cross-section: 6 mm²
  • Conductor diameter: 3.0 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 13.0 mm
  • Maximum outer diameter: 13.91 mm
  • Approximate weight: 294 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 52 A
  • Permissible current rating when buried: 64 A

 

EX 3*6RE

Nexans ref. EX 100502 - Country ref. EX 3*6RE

  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular
  • Number of conductors: 3
  • Conductor cross-section: 6 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 12.5 mm
  • Maximum outer diameter: 13.5 mm
  • Approximate weight: 296 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 58 A
  • Permissible current rating when buried: 74 A

 

EX 3*70SM

Nexans ref. EX 001901 - Country ref. EX 3*70SM

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Shaped
  • Number of conductors: 3
  • Conductor cross-section: 70 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.1 mm
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 27.0 mm
  • Maximum outer diameter: 28.89 mm
  • Approximate weight: 2104 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 242 A
  • Permissible current rating when buried: 252 A

 

EX 3*95SM

Nexans ref. EX 002001 - Country ref. EX 3*95SM

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Shaped
  • Number of conductors: 3
  • Conductor cross-section: 95 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.1 mm
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 30.0 mm
  • Maximum outer diameter: 32.1 mm
  • Approximate weight: 2832 kg/km
  • Number of cores: 3
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 293 A
  • Permissible current rating when buried: 302 A

 

EX 37*1.5 NEW

Nexans ref. EX 005681 - Country ref. EX 37*1.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 37
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 24.0 mm
  • Maximum outer diameter: 25.68 mm
  • Approximate weight: 849 kg/km
  • Number of cores: 37
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 34 A

 

EX 4*1.5

Nexans ref. EX 002611 - Country ref. EX 4*1.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 4
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 11.0 mm
  • Maximum outer diameter: 11.77 mm
  • Approximate weight: 150 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 22 A
  • Permissible current rating when buried: 29 A

 

EX 4*1.5RE

Nexans ref. EX 002601 - Country ref. EX 4*1.5RE

  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Number of conductors: 4
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: 1.7 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 10.0 mm
  • Maximum outer diameter: 10.7 mm
  • Approximate weight: 153 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 30 A
  • Permissible current rating when buried: 40 A

 

EX 4*10

Nexans ref. EX 003101 - Country ref. EX 4*10

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 4
  • Conductor cross-section: 10 mm²
  • Conductor diameter: 3.76 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 16.0 mm
  • Maximum outer diameter: 17.12 mm
  • Approximate weight: 548 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 71 A
  • Permissible current rating when buried: 88 A

 

EX 4*120SM

Nexans ref. EX 003801 - Country ref. EX 4*120SM

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Shaped
  • Number of conductors: 4
  • Conductor cross-section: 120 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.2 mm
  • Nominal outer sheath thickness: 2.3 mm
  • Nominal outer diameter: 39.0 mm
  • Maximum outer diameter: 41.73 mm
  • Approximate weight: 4764 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating in open air: 339 A
  • Permissible current rating when buried: 345 A

 

EX 4*150SM

Nexans ref. EX 003901 - Country ref. EX 4*150SM

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Shaped
  • Number of conductors: 4
  • Conductor cross-section: 150 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.4 mm
  • Nominal outer sheath thickness: 2.4 mm
  • Nominal outer diameter: 43.0 mm
  • Maximum outer diameter: 46.01 mm
  • Approximate weight: 5866 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating in open air: 390 A
  • Permissible current rating when buried: 386 A

 

EX 4*16

Nexans ref. EX 003201 - Country ref. EX 4*16

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 4
  • Conductor cross-section: 16 mm²
  • Conductor diameter: 4.67 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 18.0 mm
  • Maximum outer diameter: 19.26 mm
  • Approximate weight: 790 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 96 A
  • Permissible current rating when buried: 111 A

 

EX 4*185SM

Nexans ref. EX 004001 - Country ref. EX 4*185SM

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Shaped
  • Number of conductors: 4
  • Conductor cross-section: 185 mm²
  • Conductor diameter: 17.65 mm
  • Nominal insulation thickness: 1.6 mm
  • Nominal outer sheath thickness: 2.6 mm
  • Nominal outer diameter: 48.0 mm
  • Maximum outer diameter: 51.36 mm
  • Approximate weight: 7235 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
  • Permissible current rating in open air: 444 A
  • Permissible current rating when buried: 435 A

 

EX 4*2.5

Nexans ref. EX 002711 - Country ref. EX 4*2.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 4
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 11.5 mm
  • Maximum outer diameter: 12.3 mm
  • Approximate weight: 200 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 30 A
  • Permissible current rating when buried: 40 A

 

EX 4*2.5RE

Nexans ref. EX 002701 - Country ref. EX 4*2.5RE

  • Packaging: Drum (m)
  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular
  • Number of conductors: 4
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: 1.8 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 11.5 mm
  • Maximum outer diameter: 12.3 mm
  • Approximate weight: 192 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 30 A
  • Permissible current rating when buried: 40 A

 

EX 4*240SM

Nexans ref. EX 004101 - Country ref. EX 4*240SM

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Shaped
  • Number of conductors: 4
  • Conductor cross-section: 240 mm²
  • Conductor diameter: 19.95 mm
  • Nominal insulation thickness: 1.7 mm
  • Nominal outer sheath thickness: 2.8 mm
  • Nominal outer diameter: 54.0 mm
  • Maximum outer diameter: 57.78 mm
  • Approximate weight: 9480 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
  • Permissible current rating in open air: 522 A
  • Permissible current rating when buried: 504 A

 

EX 4*25

Nexans ref. EX 003301 - Country ref. EX 4*25

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 4
  • Conductor cross-section: 25 mm²
  • Conductor diameter: 5.87 mm
  • Nominal insulation thickness: 0.9 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 22.0 mm
  • Maximum outer diameter: 23.54 mm
  • Approximate weight: 1206 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 127 A
  • Permissible current rating when buried: 141 A

 

EX 4*300SM

Nexans ref. EX 004116 - Country ref. EX 4*300SM

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Shaped
  • Number of conductors: 4
  • Conductor cross-section: 300 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.8 mm
  • Nominal outer sheath thickness: 3.0 mm
  • Nominal outer diameter: 60.0 mm
  • Maximum outer diameter: 64.2 mm
  • Approximate weight: 11969 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
  • Permissible current rating in open air: 595 A
  • Permissible current rating when buried: 571 A

 

EX 4*35

Nexans ref. EX 003402 - Country ref. EX 4*35

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 4
  • Conductor cross-section: 35 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.9 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 24.0 mm
  • Maximum outer diameter: 25.68 mm
  • Approximate weight: 1487 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 157 A
  • Permissible current rating when buried: 170 A

 

EX 4*4

Nexans ref. EX 002901 - Country ref. EX 4*4

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 4
  • Conductor cross-section: 4 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 13.0 mm
  • Maximum outer diameter: 13.91 mm
  • Approximate weight: 272 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 40 A
  • Permissible current rating when buried: 51 A

 

EX 4*400

Nexans ref. EX 004122 - Country ref. EX 4*400

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 4
  • Conductor cross-section: 400 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 2.0 mm
  • Nominal outer sheath thickness: 3.3 mm
  • Nominal outer diameter: 72.0 mm
  • Maximum outer diameter: 77.04 mm
  • Approximate weight: 15471 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
  • Permissible current rating in open air: 695 A
  • Permissible current rating when buried: 657 A

 

EX 4*4RE

Nexans ref. EX 002801 - Country ref. EX 4*4RE

  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Number of conductors: 4
  • Conductor cross-section: 4 mm²
  • Conductor diameter: 2.3 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 12.5 mm
  • Maximum outer diameter: 13.38 mm
  • Approximate weight: 263 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 40 A
  • Permissible current rating when buried: 51 A

 

EX 4*50

Nexans ref. EX 003425 - Country ref. EX 4*50

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 4
  • Conductor cross-section: 50 mm²
  • Conductor diameter: 8.1 mm
  • Nominal insulation thickness: 1.0 mm
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 28.0 mm
  • Maximum outer diameter: 29.96 mm
  • Approximate weight: 2040 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 190 A
  • Permissible current rating when buried: 204 A

 

EX 4*500

Nexans ref. EX 004123 - Country ref. EX 4*500

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 4
  • Conductor cross-section: 500 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 2.2 mm
  • Nominal outer sheath thickness: 3.5 mm
  • Nominal outer diameter: 80.0 mm
  • Maximum outer diameter: 85.6 mm
  • Approximate weight: 19716 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 0.0366 Ohm/km
  • Permissible current rating in open air: 777 A
  • Permissible current rating when buried: 735 A

 

EX 4*6

Nexans ref. EX 003001 - Country ref. EX 4*6

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 4
  • Conductor cross-section: 6 mm²
  • Conductor diameter: 3.0 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 14.0 mm
  • Maximum outer diameter: 14.98 mm
  • Approximate weight: 362 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 52 A
  • Permissible current rating when buried: 64 A

 

EX 4*6RE

Nexans ref. EX 100503 - Country ref. EX 4*6RE

  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular
  • Number of conductors: 4
  • Conductor cross-section: 6 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 13.5 mm
  • Maximum outer diameter: 14.5 mm
  • Approximate weight: 364 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 58 A
  • Permissible current rating when buried: 74 A

 

EX 4*70SM

Nexans ref. EX 003601 - Country ref. EX 4*70SM

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Shaped
  • Number of conductors: 4
  • Conductor cross-section: 70 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.1 mm
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 31.0 mm
  • Maximum outer diameter: 33.17 mm
  • Approximate weight: 2772 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 242 A
  • Permissible current rating when buried: 252 A

 

EX 4*95SM

Nexans ref. EX 003701 - Country ref. EX 4*95SM

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Shaped
  • Number of conductors: 4
  • Conductor cross-section: 95 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.1 mm
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 35.0 mm
  • Maximum outer diameter: 37.45 mm
  • Approximate weight: 3757 kg/km
  • Number of cores: 4
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 293 A
  • Permissible current rating when buried: 302 A

 

EX 5*1.5

Nexans ref. EX 005613 - Country ref. EX 5*1.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 5
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 11.0 mm
  • Maximum outer diameter: 11.77 mm
  • Approximate weight: 168 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 22 A
  • Permissible current rating when buried: 29 A

 

EX 5*1.5RE

Nexans ref. EX 005611 - Country ref. EX 5*1.5RE

  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular solid (RE)
  • Number of conductors: 5
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: 1.7 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 11.0 mm
  • Maximum outer diameter: 11.77 mm
  • Approximate weight: 162 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 30 A
  • Permissible current rating when buried: 40 A

 

EX 5*10

Nexans ref. EX 006361 - Country ref. EX 5*10

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 5
  • Conductor cross-section: 10 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 17.5 mm
  • Maximum outer diameter: 18.73 mm
  • Approximate weight: 652 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 71 A
  • Permissible current rating when buried: 88 A

 

EX 5*120

Nexans ref. EX 006427 - Country ref. EX 5*120

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 5
  • Conductor cross-section: 120 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.2 mm
  • Nominal outer sheath thickness: 2.4 mm
  • Nominal outer diameter: 46.0 mm
  • Maximum outer diameter: 49.22 mm
  • Approximate weight: 6063 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating in open air: 339 A
  • Permissible current rating when buried: 345 A

 

EX 5*150

Nexans ref. EX 006429 - Country ref. EX 5*150

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 5
  • Conductor cross-section: 150 mm²
  • Conductor diameter: 14.2 mm
  • Nominal insulation thickness: 1.4 mm
  • Nominal outer sheath thickness: 2.6 mm
  • Nominal outer diameter: 50.0 mm
  • Maximum outer diameter: 40.7 mm
  • Approximate weight: 7382 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating in open air: 390 A
  • Permissible current rating when buried: 386 A

 

EX 5*16

Nexans ref. EX 006371 - Country ref. EX 5*16

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 5
  • Conductor cross-section: 16 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 19.5 mm
  • Maximum outer diameter: 20.86 mm
  • Approximate weight: 910 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 96 A
  • Permissible current rating when buried: 111 A

 

EX 5*185

Nexans ref. EX 006430 - Country ref. EX 5*185

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 5
  • Conductor cross-section: 185 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.6 mm
  • Nominal outer sheath thickness: 2.8 mm
  • Nominal outer diameter: 57.0 mm
  • Maximum outer diameter: 60.99 mm
  • Approximate weight: 9215 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
  • Permissible current rating in open air: 444 A
  • Permissible current rating when buried: 435 A

 

EX 5*2.5

Nexans ref. EX 006016 - Country ref. EX 5*2.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 5
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 12.5 mm
  • Maximum outer diameter: 13.38 mm
  • Approximate weight: 224 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 30 A
  • Permissible current rating when buried: 40 A

 

EX 5*2.5//C

Nexans ref. EX 000027 - Country ref. EX 5*2.5//C

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 5
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 12.5 mm
  • Maximum outer diameter: 13.38 mm
  • Approximate weight: 224 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 30 A
  • Permissible current rating when buried: 40 A

 

EX 5*2.5RE

Nexans ref. EX 006011 - Country ref. EX 5*2.5RE

  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular
  • Number of conductors: 5
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: 1.8 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 12.0 mm
  • Maximum outer diameter: 12.84 mm
  • Approximate weight: 220 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 30 A
  • Permissible current rating when buried: 40 A

 

EX 5*240

Nexans ref. EX 006432 - Country ref. EX 5*240

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 5
  • Conductor cross-section: 240 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.7 mm
  • Nominal outer sheath thickness: 3.0 mm
  • Nominal outer diameter: 64.0 mm
  • Maximum outer diameter: 68.48 mm
  • Approximate weight: 11909 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
  • Permissible current rating in open air: 522 A
  • Permissible current rating when buried: 504 A

 

EX 5*25

Nexans ref. EX 006381 - Country ref. EX 5*25

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 5
  • Conductor cross-section: 25 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.9 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 24.0 mm
  • Maximum outer diameter: 25.68 mm
  • Approximate weight: 1381 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 127 A
  • Permissible current rating when buried: 141 A

 

EX 5*35

Nexans ref. EX 006391 - Country ref. EX 5*35

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 5
  • Conductor cross-section: 35 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.9 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 27.0 mm
  • Maximum outer diameter: 28.89 mm
  • Approximate weight: 1828 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 157 A
  • Permissible current rating when buried: 170 A

 

EX 5*4

Nexans ref. EX 006341 - Country ref. EX 5*4

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 5
  • Conductor cross-section: 4 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 14.0 mm
  • Maximum outer diameter: 14.98 mm
  • Approximate weight: 326 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 40 A
  • Permissible current rating when buried: 51 A

 

EX 5*400

Nexans ref. EX 000717 - Country ref. EX 5*400

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 5
  • Conductor cross-section: 400 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 2.0 mm
  • Nominal outer sheath thickness: 3.5 mm
  • Nominal outer diameter: 80.0 mm
  • Maximum outer diameter: 85.6 mm
  • Approximate weight: 19035 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
  • Permissible current rating in open air: 695 A
  • Permissible current rating when buried: 657 A

 

EX 5*4RE

Nexans ref. EX 006331 - Country ref. EX 5*4RE

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular solid (RE)
  • Number of conductors: 5
  • Conductor cross-section: 4 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 14.0 mm
  • Maximum outer diameter: 14.98 mm
  • Approximate weight: 315 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 40 A
  • Permissible current rating when buried: 51 A

 

EX 5*50

Nexans ref. EX 006401 - Country ref. EX 5*50

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 5
  • Conductor cross-section: 50 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.0 mm
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 31.0 mm
  • Maximum outer diameter: 33.17 mm
  • Approximate weight: 2484 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 190 A
  • Permissible current rating when buried: 204 A

 

EX 5*6

Nexans ref. EX 006351 - Country ref. EX 5*6

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 5
  • Conductor cross-section: 6 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 15.5 mm
  • Maximum outer diameter: 16.59 mm
  • Approximate weight: 435 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 52 A
  • Permissible current rating when buried: 64 A

 

EX 5*6RE

Nexans ref. EX 006012 - Country ref. EX 5*6RE

  • Conductor flexibility: Solid class 1
  • Conductor shape: Circular
  • Number of conductors: 5
  • Conductor cross-section: 6 mm²
  • Conductor diameter: 2.3 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 14.5 mm
  • Maximum outer diameter: 15.5 mm
  • Approximate weight: 440 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 58 A
  • Permissible current rating when buried: 74 A

 

EX 5*70

Nexans ref. EX 006411 - Country ref. EX 5*70

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 5
  • Conductor cross-section: 70 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.1 mm
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 36.0 mm
  • Maximum outer diameter: 38.52 mm
  • Approximate weight: 3511 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 242 A
  • Permissible current rating when buried: 252 A

 

EX 5*95

Nexans ref. EX 006421 - Country ref. EX 5*95

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 5
  • Conductor cross-section: 95 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 1.1 mm
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 41.0 mm
  • Maximum outer diameter: 43.87 mm
  • Approximate weight: 4745 kg/km
  • Number of cores: 5
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 293 A
  • Permissible current rating when buried: 302 A

 

EX 6*1.5 NEW

Nexans ref. EX 005617 - Country ref. EX 6*1.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 6
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 12.0 mm
  • Maximum outer diameter: 12.84 mm
  • Approximate weight: 193 kg/km
  • Number of cores: 6
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 34 A

 

EX 6*2.5

Nexans ref. EX 006017 - Country ref. EX 6*2.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 6
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: 1.9 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 13.5 mm
  • Maximum outer diameter: 14.45 mm
  • Approximate weight: 262 kg/km
  • Number of cores: 6
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 46 A

 

EX 7*1.5

Nexans ref. EX 005623 - Country ref. EX 7*1.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 7
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 12.0 mm
  • Maximum outer diameter: 12.84 mm
  • Approximate weight: 208 kg/km
  • Number of cores: 7
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 34 A

 

EX 7*2.5

Nexans ref. EX 006026 - Country ref. EX 7*2.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 7
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 13.5 mm
  • Maximum outer diameter: 14.45 mm
  • Approximate weight: 283 kg/km
  • Number of cores: 7
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 46 A

 

EX 7*4

Nexans ref. EX 006343 - Country ref. EX 7*4

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 7
  • Conductor cross-section: 4 mm²
  • Conductor diameter: 2.43 mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 15.0 mm
  • Maximum outer diameter: 16.0 mm
  • Approximate weight: 395 kg/km
  • Number of cores: 7
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 45 A
  • Permissible current rating when buried: 59 A

 

EX 8*1.5 NEW

Nexans ref. EX 001707 - Country ref. EX 8*1.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 8
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 13.0 mm
  • Maximum outer diameter: 13.91 mm
  • Approximate weight: 239 kg/km
  • Number of cores: 8
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 34 A

 

EX 8*2.5

Nexans ref. EX 004756 - Country ref. EX 8*2.5

  • Packaging: Drum (m)
  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 8
  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 14.5 mm
  • Maximum outer diameter: 15.52 mm
  • Approximate weight: 325 kg/km
  • Number of cores: 8
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 46 A

 

EX 9*1.5

Nexans ref. EX 005639 - Country ref. EX 9*1.5

  • Conductor flexibility: Class 2 IEC 60228
  • Conductor shape: Circular
  • Number of conductors: 9
  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: - mm
  • Nominal insulation thickness: 0.7 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 14.4 mm
  • Maximum outer diameter: 15.41 mm
  • Approximate weight: 274 kg/km
  • Number of cores: 9
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 24 A
  • Permissible current rating when buried: 34 A

 

Description

Description

Standards

  • Product
    IEC 60228; IEC 60502-1
  • Test
    IEC 60332-1-2

Scope

This specification covers XLPE insulated, circular or shaped, multicore unarmoured cables, rated at 0.6/1 KV according to IEC 60502-1 for use indoors, outdoors, and in cable ducts.

Construction

2.1 Conductor

Plain, annealed electrolytic copper conductors, circular stranded, or sectoral stranded, conforming to the applicable requirements of IEC 60228.

2.2 Insulation

XLPE material, conforming to the applicable requirements of IEC 60502-1.

2.3 Assembly

Insulated conductors are laid up, filled where necessary with non-hygroscopic material.

2.4 Sheath

PVC based thermoplastic material, conforming to the applicable requirements of IEC 60502-1.

2.5 TESTS

Conforming to the applicable requirements of IEC 60502-1 either on Raw materials or on finished products.

TEST AT WORKS unarmored multicore

Routine Tests                                                              

 - Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag. 15.1 & 15.2

 - Voltage test acc. to IEC 60502-1  parag. 15.1 & 15.3                                                   

                                                                       

Liban Cables will carry out these tests on all the lengths and tests certificates will be provided .

                                                                       

Sample Tests                                                              

 - Check of the build - up and color coding of the cable

 - Check of dimensions                                                 

            Insulation          :           according to IEC 60502-1                       Parag.  16.5.2

            Oversheath       :           according to IEC 60502-1                       Parag.  16.5.3

 

These tests will be carried out on one length of each size during each inspection .

Tests certificates will be provided by Liban Cables

                                                                       

Type Tests                                                                  

Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-1.

These tests will be carried out on one length of the order .

Tests certificates will be provided by Liban Cables

DRAWING LV UNARMORED CIRCULAR CONDUCTORS

DRAWING LV UNARMORED SHAPED CONDUCTORS

Cable identification - LV cables ≤ 1KV

INSULATION COLORS:   

 

Neutral

Cond.1

Cond.2

 Cond.3

Cond.4

1 Conductor

 

BLACK

 

 

 

2 Conductors

GREY

BLACK

 

 

 

3 Conductors

 

BLACK

RED

BLUE

 

4 Conductors

GREY

BLACK

RED

BLUE

 

5 Conductors

GREY

BLACK

RED

BLUE

GREEN

 

All numbered control cables (6 conductors and above), are insulated with white color, and numbered with black digits

 

CABLE MARKING OVER THE OUTER JACKET  (by inkjet printing):

LIBAN CABLES     DESCRIPTION     RATED VOLTAGE     SECTION MM2     Year of manufacture     meter marking

 

Other cable identification requirements are available upon request

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Insulation
XLPE
Outer sheath
PVC
With Green/Yellow core
No

Electrical characteristics

Electrical characteristics

Thermal soil resistivity wet zone
1 °K.m/W
Test voltage
3500 V
Rated Voltage Uo/U (Um)
0,6/1 kV

Mechanical characteristics

Mechanical characteristics

Cable flexibility
6xD

Usage characteristics

Usage characteristics

Laying depth, center of system
600 mm
Operating temperature, range
-15 ... 55 °C
Installation temperature, range
-5 ... 50 °C
Ambient air temperature
30 °C
Max. conductor temperature in service
90 °C
Short-circuit max. conductor temperature
250 °C
Flame retardant
IEC 60332-1-2

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close