Unarmored, multicore XLPE insulation, PVC sheathed
Unarmored, multicore XLPE insulation, PVC sheathed
0.6 / 1 KV POWER CABLES Conforming to IEC 60502-1
Read moreEX 10*1.5 NEW
Nexans ref. EX 005653 - Country ref. EX 10*1.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 10
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.5 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 15.0 mm
- Maximum outer diameter: 16.05 mm
- Approximate weight: 286 kg/km
- Number of cores: 10
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EX 10*2.5
Nexans ref. EX 006035 - Country ref. EX 10*2.5
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 10
- Conductor cross-section: 2.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 16.5 mm
- Maximum outer diameter: 17.66 mm
- Approximate weight: 392 kg/km
- Number of cores: 10
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 46 A
EX 10*6
Nexans ref. EX 006347 - Country ref. EX 10*6
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 10
- Conductor cross-section: 6 mm²
- Conductor diameter: 4.37 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 21.0 mm
- Maximum outer diameter: 22.47 mm
- Approximate weight: 754 kg/km
- Number of cores: 10
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 58 A
- Permissible current rating when buried: 74 A
EX 11*1.5
Nexans ref. EX 105653 - Country ref. EX 11*1.5
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 11
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 15.0 mm
- Maximum outer diameter: 16.05 mm
- Approximate weight: 308 kg/km
- Number of cores: 11
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EX 12*1.5
Nexans ref. EX 005629 - Country ref. EX 12*1.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 12
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 15.0 mm
- Maximum outer diameter: 16.05 mm
- Approximate weight: 326 kg/km
- Number of cores: 12
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EX 12*2.5
Nexans ref. EX 006038 - Country ref. EX 12*2.5
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 12
- Conductor cross-section: 2.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 17.0 mm
- Maximum outer diameter: 18.2 mm
- Approximate weight: 451 kg/km
- Number of cores: 12
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 46 A
EX 12*4
Nexans ref. EX 006345 - Country ref. EX 12*4
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 12
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.43 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 19.5 mm
- Maximum outer diameter: 20.6 mm
- Approximate weight: 395 kg/km
- Number of cores: 12
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 45 A
- Permissible current rating when buried: 59 A
EX 13*1.5
Nexans ref. EX 105654 - Country ref. EX 13*1.5
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 13
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 16.0 mm
- Maximum outer diameter: 17.2 mm
- Approximate weight: 351 kg/km
- Number of cores: 13
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EX 15*1.5 NEW
Nexans ref. EX 003669 - Country ref. EX 15*1.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 15
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 17.0 mm
- Maximum outer diameter: 18.19 mm
- Approximate weight: 393 kg/km
- Number of cores: 15
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EX 15*2.5
Nexans ref. EX 006117 - Country ref. EX 15*2.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 15
- Conductor cross-section: 2.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 19.0 mm
- Maximum outer diameter: 20.33 mm
- Approximate weight: 547 kg/km
- Number of cores: 15
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 46 A
EX 16*1.5
Nexans ref. EX 001886 - Country ref. EX 16*1.5
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 16
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.5 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 17.0 mm
- Maximum outer diameter: 18.2 mm
- Approximate weight: 418 kg/km
- Number of cores: 16
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EX 16*2.5
Nexans ref. EX 006055 - Country ref. EX 16*2.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 16
- Conductor cross-section: 2.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 19.0 mm
- Maximum outer diameter: 20.33 mm
- Approximate weight: 578 kg/km
- Number of cores: 16
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 46 A
EX 18*1.5
Nexans ref. EX 000913 - Country ref. EX 18*1.5
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 18
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 17.5 mm
- Maximum outer diameter: 18.8 mm
- Approximate weight: 459 kg/km
- Number of cores: 18
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EX 19*1.5 NEW
Nexans ref. EX 005641 - Country ref. EX 19*1.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 19
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.48 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 18.0 mm
- Maximum outer diameter: 19.26 mm
- Approximate weight: 473 kg/km
- Number of cores: 19
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EX 19*2.5
Nexans ref. EX 006056 - Country ref. EX 19*2.5
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 19
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 1.93 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 20.0 mm
- Maximum outer diameter: 17.66 mm
- Approximate weight: 660 kg/km
- Number of cores: 19
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 46 A
EX 2*1.5
Nexans ref. EX 000330 - Country ref. EX 2*1.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 2
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 9.5 mm
- Maximum outer diameter: 10.16 mm
- Approximate weight: 110 kg/km
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EX 2*1.5RE
Nexans ref. EX 000325 - Country ref. EX 2*1.5RE
- Conductor flexibility: Solid class 1
- Conductor shape: Circular solid (RE)
- Number of conductors: 2
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.7 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 9.0 mm
- Maximum outer diameter: 9.63 mm
- Approximate weight: 106 kg/km
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EX 2*10
Nexans ref. EX 000601 - Country ref. EX 2*10
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 2
- Conductor cross-section: 10 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 14.0 mm
- Maximum outer diameter: 14.98 mm
- Approximate weight: 341 kg/km
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 80 A
- Permissible current rating when buried: 101 A
EX 2*120
Nexans ref. EX 000865 - Country ref. EX 2*120
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 2
- Conductor cross-section: 120 mm²
- Conductor diameter: 12.9 mm
- Nominal insulation thickness: 1.2 mm
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 35.0 mm
- Maximum outer diameter: 37.45 mm
- Approximate weight: 2994 kg/km
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating in open air: 379 A
- Permissible current rating when buried: 397 A
EX 2*150
Nexans ref. EX 000870 - Country ref. EX 2*150
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 2
- Conductor cross-section: 150 mm²
- Conductor diameter: 14.2 mm
- Nominal insulation thickness: 1.4 mm
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 38.0 mm
- Maximum outer diameter: 40.7 mm
- Approximate weight: 3702 kg/km
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating in open air: 435 A
- Permissible current rating when buried: 444 A
EX 2*16
Nexans ref. EX 000701 - Country ref. EX 2*16
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 2
- Conductor cross-section: 16 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 15.5 mm
- Maximum outer diameter: 16.59 mm
- Approximate weight: 481 kg/km
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 107 A
- Permissible current rating when buried: 128 A
EX 2*2.5 NEW
Nexans ref. EX 000343 - Country ref. EX 2*2.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 2
- Conductor cross-section: 2.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 10.0 mm
- Maximum outer diameter: 10.7 mm
- Approximate weight: 140 kg/km
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 46 A
EX 2*2.5RE
Nexans ref. EX 000335 - Country ref. EX 2*2.5RE
- Packaging: Drum (m)
- Conductor flexibility: Class 1 acc. to IEC 60228
- Conductor shape: Circular
- Number of conductors: 2
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 1.755 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 9.8 mm
- Maximum outer diameter: 10.5 mm
- Approximate weight: 141 kg/km
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 46 A
EX 2*25
Nexans ref. EX 000801 - Country ref. EX 2*25
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 2
- Conductor cross-section: 25 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.9 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 18.5 mm
- Maximum outer diameter: 19.8 mm
- Approximate weight: 730 kg/km
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 142 A
- Permissible current rating when buried: 162 A
EX 2*35
Nexans ref. EX 000811 - Country ref. EX 2*35
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 2
- Conductor cross-section: 35 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.9 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 21.0 mm
- Maximum outer diameter: 22.47 mm
- Approximate weight: 953 kg/km
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 175 A
- Permissible current rating when buried: 195 A
EX 2*4 NEW
Nexans ref. EX 000401 - Country ref. EX 2*4
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 2
- Conductor cross-section: 4 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 11.0 mm
- Maximum outer diameter: 11.77 mm
- Approximate weight: 184 kg/km
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 45 A
- Permissible current rating when buried: 59 A
EX 2*50
Nexans ref. EX 000821 - Country ref. EX 2*50
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 2
- Conductor cross-section: 50 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 24.0 mm
- Maximum outer diameter: 25.68 mm
- Approximate weight: 1271 kg/km
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 212 A
- Permissible current rating when buried: 235 A
EX 2*6 NEW
Nexans ref. EX 000501 - Country ref. EX 2*6
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 2
- Conductor cross-section: 6 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 12.0 mm
- Maximum outer diameter: 12.84 mm
- Approximate weight: 239 kg/km
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 58 A
- Permissible current rating when buried: 74 A
EX 2*6RE
Nexans ref. EX 100501 - Country ref. EX 2*6RE
- Conductor flexibility: Solid class 1
- Conductor shape: Circular
- Number of conductors: 2
- Conductor cross-section: 6 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 11.5 mm
- Maximum outer diameter: 12.3 mm
- Approximate weight: 239 kg/km
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 58 A
- Permissible current rating when buried: 74 A
EX 2*95
Nexans ref. EX 000839 - Country ref. EX 2*95
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 2
- Conductor cross-section: 95 mm²
- Conductor diameter: 11.4 mm
- Nominal insulation thickness: 1.1 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 31.0 mm
- Maximum outer diameter: 33.2 mm
- Approximate weight: 1271 kg/km
- Number of cores: 2
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating in open air: 327 A
- Permissible current rating when buried: 347 A
EX 20*1.5 NEW
Nexans ref. EX 005644 - Country ref. EX 20*1.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 20
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 19.0 mm
- Maximum outer diameter: 20.33 mm
- Approximate weight: 504 kg/km
- Number of cores: 20
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EX 24*1.5
Nexans ref. EX 005663 - Country ref. EX 24*1.5
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 24
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.48 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 20.5 mm
- Maximum outer diameter: 16.05 mm
- Approximate weight: 588 kg/km
- Number of cores: 24
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EX 24*2.5
Nexans ref. EX 006059 - Country ref. EX 24*2.5
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 24
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 1.93 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 23.5 mm
- Maximum outer diameter: 25.1 mm
- Approximate weight: 829 kg/km
- Number of cores: 24
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 46 A
EX 25*1.5
Nexans ref. EX 000070 - Country ref. EX 25*1.5
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 25
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 21.0 mm
- Maximum outer diameter: 22.47 mm
- Approximate weight: 610 kg/km
- Number of cores: 25
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EX 27*1.5 NEW
Nexans ref. EX 005666 - Country ref. EX 27*1.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 27
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 21.0 mm
- Maximum outer diameter: 22.47 mm
- Approximate weight: 646 kg/km
- Number of cores: 27
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EX 3*1
Nexans ref. EX 000060 - Country ref. EX 3*1
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 1 mm²
- Conductor diameter: 1.3 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 9.2 mm
- Maximum outer diameter: 9.85 mm
- Approximate weight: 114 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 18.1 Ohm/km
- Permissible current rating in open air: 17 A
- Permissible current rating when buried: 21 A
EX 3*1.5
Nexans ref. EX 001011 - Country ref. EX 3*1.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 10.0 mm
- Maximum outer diameter: 10.7 mm
- Approximate weight: 127 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 22 A
- Permissible current rating when buried: 29 A
EX 3*1.5RE
Nexans ref. EX 000901 - Country ref. EX 3*1.5RE
- Conductor flexibility: Solid class 1
- Conductor shape: Circular solid (RE)
- Number of conductors: 3
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.7 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 9.5 mm
- Maximum outer diameter: 10.16 mm
- Approximate weight: 124 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 22 A
- Permissible current rating when buried: 29 A
EX 3*1.5RE - M
Nexans ref. EX 700901 - Country ref. EX 3*1.5RE//COIL-M
- Packaging: Coil (100m)
- Conductor flexibility: Solid class 1
- Conductor shape: Circular solid (RE)
- Number of conductors: 3
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.7 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 9.5 mm
- Maximum outer diameter: 10.16 mm
- Approximate weight: 124 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 22 A
- Permissible current rating when buried: 29 A
EX 3*10
Nexans ref. EX 001401 - Country ref. EX 3*10
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 10 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 14.5 mm
- Maximum outer diameter: 15.52 mm
- Approximate weight: 431 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 71 A
- Permissible current rating when buried: 88 A
EX 3*120SM
Nexans ref. EX 002101 - Country ref. EX 3*120SM
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Shaped
- Number of conductors: 3
- Conductor cross-section: 120 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.2 mm
- Nominal outer sheath thickness: 2.1 mm
- Nominal outer diameter: 34.0 mm
- Maximum outer diameter: 36.38 mm
- Approximate weight: 3757 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating in open air: 339 A
- Permissible current rating when buried: 345 A
EX 3*150SM
Nexans ref. EX 002201 - Country ref. EX 3*150SM
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Shaped
- Number of conductors: 3
- Conductor cross-section: 150 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.4 mm
- Nominal outer sheath thickness: 2.3 mm
- Nominal outer diameter: 40.0 mm
- Maximum outer diameter: 42.8 mm
- Approximate weight: 4441 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating in open air: 390 A
- Permissible current rating when buried: 386 A
EX 3*16
Nexans ref. EX 001501 - Country ref. EX 3*16
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 16 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 16.5 mm
- Maximum outer diameter: 17.66 mm
- Approximate weight: 620 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 96 A
- Permissible current rating when buried: 111 A
EX 3*185SM
Nexans ref. EX 002301 - Country ref. EX 3*185SM
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Shaped
- Number of conductors: 3
- Conductor cross-section: 185 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.6 mm
- Nominal outer sheath thickness: 2.4 mm
- Nominal outer diameter: 42.0 mm
- Maximum outer diameter: 44.94 mm
- Approximate weight: 5452 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
- Permissible current rating in open air: 444 A
- Permissible current rating when buried: 435 A
EX 3*2.5
Nexans ref. EX 001015 - Country ref. EX 3*2.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 2.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 11.0 mm
- Maximum outer diameter: 11.77 mm
- Approximate weight: 166 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 30 A
- Permissible current rating when buried: 40 A
EX 3*2.5RE
Nexans ref. EX 001001 - Country ref. EX 3*2.5RE
- Conductor flexibility: Solid class 1
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 1.8 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 11.0 mm
- Maximum outer diameter: 11.77 mm
- Approximate weight: 160 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 30 A
- Permissible current rating when buried: 40 A
EX 3*2.5RE - M
Nexans ref. EX 701001 - Country ref. EX 3*2.5RE//COIL-M
- Packaging: Coil (100m)
- Conductor flexibility: Solid class 1
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 1.8 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 11.0 mm
- Maximum outer diameter: 11.77 mm
- Approximate weight: 160 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 30 A
- Permissible current rating when buried: 40 A
EX 3*240SM
Nexans ref. EX 002401 - Country ref. EX 3*240SM
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Shaped
- Number of conductors: 3
- Conductor cross-section: 240 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.7 mm
- Nominal outer sheath thickness: 2.6 mm
- Nominal outer diameter: 47.0 mm
- Maximum outer diameter: 50.29 mm
- Approximate weight: 7123 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
- Permissible current rating in open air: 522 A
- Permissible current rating when buried: 504 A
EX 3*25
Nexans ref. EX 001601 - Country ref. EX 3*25
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 25 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.9 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 20.0 mm
- Maximum outer diameter: 21.4 mm
- Approximate weight: 942 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 127 A
- Permissible current rating when buried: 141 A
EX 3*300SM
Nexans ref. EX 002501 - Country ref. EX 3*300SM
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Shaped
- Number of conductors: 3
- Conductor cross-section: 300 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.8 mm
- Nominal outer sheath thickness: 2.8 mm
- Nominal outer diameter: 52.0 mm
- Maximum outer diameter: 55.64 mm
- Approximate weight: 8996 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
- Permissible current rating in open air: 595 A
- Permissible current rating when buried: 571 A
EX 3*35
Nexans ref. EX 001705 - Country ref. EX 3*35
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 35 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.9 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 22.0 mm
- Maximum outer diameter: 23.54 mm
- Approximate weight: 1149 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 157 A
- Permissible current rating when buried: 170 A
EX 3*4
Nexans ref. EX 001201 - Country ref. EX 3*4
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.4 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 12.0 mm
- Maximum outer diameter: 12.84 mm
- Approximate weight: 223 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 40 A
- Permissible current rating when buried: 51 A
EX 3*400
Nexans ref. EX 004860 - Country ref. EX 3*400
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 400 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 2.0 mm
- Nominal outer sheath thickness: 3.1 mm
- Nominal outer diameter: 64.0 mm
- Maximum outer diameter: 68.48 mm
- Approximate weight: 11683 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
- Permissible current rating in open air: 695 A
- Permissible current rating when buried: 657 A
EX 3*4RE
Nexans ref. EX 001101 - Country ref. EX 3*4RE
- Conductor flexibility: Solid class 1
- Conductor shape: Circular solid (RE)
- Number of conductors: 3
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.3 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 11.5 mm
- Maximum outer diameter: 12.3 mm
- Approximate weight: 224 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 40 A
- Permissible current rating when buried: 51 A
EX 3*50
Nexans ref. EX 004052 - Country ref. EX 3*50
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 50 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 25.0 mm
- Maximum outer diameter: 26.75 mm
- Approximate weight: 1548 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 190 A
- Permissible current rating when buried: 204 A
EX 3*500
Nexans ref. EX 001250 - Country ref. EX 3*500
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 500 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 2.2 mm
- Nominal outer sheath thickness: 3.2 mm
- Nominal outer diameter: 72.0 mm
- Maximum outer diameter: 77.04 mm
- Approximate weight: 14907 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 0.0366 Ohm/km
- Permissible current rating in open air: 777 A
- Permissible current rating when buried: 735 A
EX 3*6
Nexans ref. EX 001202 - Country ref. EX 3*6
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 6 mm²
- Conductor diameter: 3.0 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 13.0 mm
- Maximum outer diameter: 13.91 mm
- Approximate weight: 294 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 52 A
- Permissible current rating when buried: 64 A
EX 3*6RE
Nexans ref. EX 100502 - Country ref. EX 3*6RE
- Conductor flexibility: Solid class 1
- Conductor shape: Circular
- Number of conductors: 3
- Conductor cross-section: 6 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 12.5 mm
- Maximum outer diameter: 13.5 mm
- Approximate weight: 296 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 58 A
- Permissible current rating when buried: 74 A
EX 3*70SM
Nexans ref. EX 001901 - Country ref. EX 3*70SM
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Shaped
- Number of conductors: 3
- Conductor cross-section: 70 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.1 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 27.0 mm
- Maximum outer diameter: 28.89 mm
- Approximate weight: 2104 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 242 A
- Permissible current rating when buried: 252 A
EX 3*95SM
Nexans ref. EX 002001 - Country ref. EX 3*95SM
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Shaped
- Number of conductors: 3
- Conductor cross-section: 95 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.1 mm
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 30.0 mm
- Maximum outer diameter: 32.1 mm
- Approximate weight: 2832 kg/km
- Number of cores: 3
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating in open air: 293 A
- Permissible current rating when buried: 302 A
EX 37*1.5 NEW
Nexans ref. EX 005681 - Country ref. EX 37*1.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 37
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 24.0 mm
- Maximum outer diameter: 25.68 mm
- Approximate weight: 849 kg/km
- Number of cores: 37
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EX 4*1.5
Nexans ref. EX 002611 - Country ref. EX 4*1.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 11.0 mm
- Maximum outer diameter: 11.77 mm
- Approximate weight: 150 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 22 A
- Permissible current rating when buried: 29 A
EX 4*1.5RE
Nexans ref. EX 002601 - Country ref. EX 4*1.5RE
- Conductor flexibility: Solid class 1
- Conductor shape: Circular solid (RE)
- Number of conductors: 4
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.7 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 10.0 mm
- Maximum outer diameter: 10.7 mm
- Approximate weight: 153 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 30 A
- Permissible current rating when buried: 40 A
EX 4*10
Nexans ref. EX 003101 - Country ref. EX 4*10
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 10 mm²
- Conductor diameter: 3.76 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 16.0 mm
- Maximum outer diameter: 17.12 mm
- Approximate weight: 548 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 71 A
- Permissible current rating when buried: 88 A
EX 4*120SM
Nexans ref. EX 003801 - Country ref. EX 4*120SM
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 120 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.2 mm
- Nominal outer sheath thickness: 2.3 mm
- Nominal outer diameter: 39.0 mm
- Maximum outer diameter: 41.73 mm
- Approximate weight: 4764 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating in open air: 339 A
- Permissible current rating when buried: 345 A
EX 4*150SM
Nexans ref. EX 003901 - Country ref. EX 4*150SM
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 150 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.4 mm
- Nominal outer sheath thickness: 2.4 mm
- Nominal outer diameter: 43.0 mm
- Maximum outer diameter: 46.01 mm
- Approximate weight: 5866 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating in open air: 390 A
- Permissible current rating when buried: 386 A
EX 4*16
Nexans ref. EX 003201 - Country ref. EX 4*16
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 16 mm²
- Conductor diameter: 4.67 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 18.0 mm
- Maximum outer diameter: 19.26 mm
- Approximate weight: 790 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 96 A
- Permissible current rating when buried: 111 A
EX 4*185SM
Nexans ref. EX 004001 - Country ref. EX 4*185SM
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 185 mm²
- Conductor diameter: 17.65 mm
- Nominal insulation thickness: 1.6 mm
- Nominal outer sheath thickness: 2.6 mm
- Nominal outer diameter: 48.0 mm
- Maximum outer diameter: 51.36 mm
- Approximate weight: 7235 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
- Permissible current rating in open air: 444 A
- Permissible current rating when buried: 435 A
EX 4*2.5
Nexans ref. EX 002711 - Country ref. EX 4*2.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 2.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 11.5 mm
- Maximum outer diameter: 12.3 mm
- Approximate weight: 200 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 30 A
- Permissible current rating when buried: 40 A
EX 4*2.5RE
Nexans ref. EX 002701 - Country ref. EX 4*2.5RE
- Packaging: Drum (m)
- Conductor flexibility: Solid class 1
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 1.8 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 11.5 mm
- Maximum outer diameter: 12.3 mm
- Approximate weight: 192 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 30 A
- Permissible current rating when buried: 40 A
EX 4*240SM
Nexans ref. EX 004101 - Country ref. EX 4*240SM
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 240 mm²
- Conductor diameter: 19.95 mm
- Nominal insulation thickness: 1.7 mm
- Nominal outer sheath thickness: 2.8 mm
- Nominal outer diameter: 54.0 mm
- Maximum outer diameter: 57.78 mm
- Approximate weight: 9480 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
- Permissible current rating in open air: 522 A
- Permissible current rating when buried: 504 A
EX 4*25
Nexans ref. EX 003301 - Country ref. EX 4*25
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 25 mm²
- Conductor diameter: 5.87 mm
- Nominal insulation thickness: 0.9 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 22.0 mm
- Maximum outer diameter: 23.54 mm
- Approximate weight: 1206 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 127 A
- Permissible current rating when buried: 141 A
EX 4*300SM
Nexans ref. EX 004116 - Country ref. EX 4*300SM
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 300 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.8 mm
- Nominal outer sheath thickness: 3.0 mm
- Nominal outer diameter: 60.0 mm
- Maximum outer diameter: 64.2 mm
- Approximate weight: 11969 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
- Permissible current rating in open air: 595 A
- Permissible current rating when buried: 571 A
EX 4*35
Nexans ref. EX 003402 - Country ref. EX 4*35
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 35 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.9 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 24.0 mm
- Maximum outer diameter: 25.68 mm
- Approximate weight: 1487 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 157 A
- Permissible current rating when buried: 170 A
EX 4*4
Nexans ref. EX 002901 - Country ref. EX 4*4
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 4 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 13.0 mm
- Maximum outer diameter: 13.91 mm
- Approximate weight: 272 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 40 A
- Permissible current rating when buried: 51 A
EX 4*400
Nexans ref. EX 004122 - Country ref. EX 4*400
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 400 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 2.0 mm
- Nominal outer sheath thickness: 3.3 mm
- Nominal outer diameter: 72.0 mm
- Maximum outer diameter: 77.04 mm
- Approximate weight: 15471 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
- Permissible current rating in open air: 695 A
- Permissible current rating when buried: 657 A
EX 4*4RE
Nexans ref. EX 002801 - Country ref. EX 4*4RE
- Conductor flexibility: Solid class 1
- Conductor shape: Circular solid (RE)
- Number of conductors: 4
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.3 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 12.5 mm
- Maximum outer diameter: 13.38 mm
- Approximate weight: 263 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 40 A
- Permissible current rating when buried: 51 A
EX 4*50
Nexans ref. EX 003425 - Country ref. EX 4*50
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 50 mm²
- Conductor diameter: 8.1 mm
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 28.0 mm
- Maximum outer diameter: 29.96 mm
- Approximate weight: 2040 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 190 A
- Permissible current rating when buried: 204 A
EX 4*500
Nexans ref. EX 004123 - Country ref. EX 4*500
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 500 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 2.2 mm
- Nominal outer sheath thickness: 3.5 mm
- Nominal outer diameter: 80.0 mm
- Maximum outer diameter: 85.6 mm
- Approximate weight: 19716 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 0.0366 Ohm/km
- Permissible current rating in open air: 777 A
- Permissible current rating when buried: 735 A
EX 4*6
Nexans ref. EX 003001 - Country ref. EX 4*6
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 6 mm²
- Conductor diameter: 3.0 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 14.0 mm
- Maximum outer diameter: 14.98 mm
- Approximate weight: 362 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 52 A
- Permissible current rating when buried: 64 A
EX 4*6RE
Nexans ref. EX 100503 - Country ref. EX 4*6RE
- Conductor flexibility: Solid class 1
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 6 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 13.5 mm
- Maximum outer diameter: 14.5 mm
- Approximate weight: 364 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 58 A
- Permissible current rating when buried: 74 A
EX 4*70SM
Nexans ref. EX 003601 - Country ref. EX 4*70SM
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 70 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.1 mm
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 31.0 mm
- Maximum outer diameter: 33.17 mm
- Approximate weight: 2772 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 242 A
- Permissible current rating when buried: 252 A
EX 4*95SM
Nexans ref. EX 003701 - Country ref. EX 4*95SM
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 95 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.1 mm
- Nominal outer sheath thickness: 2.1 mm
- Nominal outer diameter: 35.0 mm
- Maximum outer diameter: 37.45 mm
- Approximate weight: 3757 kg/km
- Number of cores: 4
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating in open air: 293 A
- Permissible current rating when buried: 302 A
EX 5*1.5
Nexans ref. EX 005613 - Country ref. EX 5*1.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 11.0 mm
- Maximum outer diameter: 11.77 mm
- Approximate weight: 168 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 22 A
- Permissible current rating when buried: 29 A
EX 5*1.5RE
Nexans ref. EX 005611 - Country ref. EX 5*1.5RE
- Conductor flexibility: Solid class 1
- Conductor shape: Circular solid (RE)
- Number of conductors: 5
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.7 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 11.0 mm
- Maximum outer diameter: 11.77 mm
- Approximate weight: 162 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 30 A
- Permissible current rating when buried: 40 A
EX 5*10
Nexans ref. EX 006361 - Country ref. EX 5*10
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 10 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 17.5 mm
- Maximum outer diameter: 18.73 mm
- Approximate weight: 652 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 71 A
- Permissible current rating when buried: 88 A
EX 5*120
Nexans ref. EX 006427 - Country ref. EX 5*120
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 120 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.2 mm
- Nominal outer sheath thickness: 2.4 mm
- Nominal outer diameter: 46.0 mm
- Maximum outer diameter: 49.22 mm
- Approximate weight: 6063 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating in open air: 339 A
- Permissible current rating when buried: 345 A
EX 5*150
Nexans ref. EX 006429 - Country ref. EX 5*150
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 150 mm²
- Conductor diameter: 14.2 mm
- Nominal insulation thickness: 1.4 mm
- Nominal outer sheath thickness: 2.6 mm
- Nominal outer diameter: 50.0 mm
- Maximum outer diameter: 40.7 mm
- Approximate weight: 7382 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating in open air: 390 A
- Permissible current rating when buried: 386 A
EX 5*16
Nexans ref. EX 006371 - Country ref. EX 5*16
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 16 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 19.5 mm
- Maximum outer diameter: 20.86 mm
- Approximate weight: 910 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 96 A
- Permissible current rating when buried: 111 A
EX 5*185
Nexans ref. EX 006430 - Country ref. EX 5*185
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 185 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.6 mm
- Nominal outer sheath thickness: 2.8 mm
- Nominal outer diameter: 57.0 mm
- Maximum outer diameter: 60.99 mm
- Approximate weight: 9215 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
- Permissible current rating in open air: 444 A
- Permissible current rating when buried: 435 A
EX 5*2.5
Nexans ref. EX 006016 - Country ref. EX 5*2.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 2.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 12.5 mm
- Maximum outer diameter: 13.38 mm
- Approximate weight: 224 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 30 A
- Permissible current rating when buried: 40 A
EX 5*2.5//C
Nexans ref. EX 000027 - Country ref. EX 5*2.5//C
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 2.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 12.5 mm
- Maximum outer diameter: 13.38 mm
- Approximate weight: 224 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 30 A
- Permissible current rating when buried: 40 A
EX 5*2.5RE
Nexans ref. EX 006011 - Country ref. EX 5*2.5RE
- Conductor flexibility: Solid class 1
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 1.8 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 12.0 mm
- Maximum outer diameter: 12.84 mm
- Approximate weight: 220 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 30 A
- Permissible current rating when buried: 40 A
EX 5*240
Nexans ref. EX 006432 - Country ref. EX 5*240
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 240 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.7 mm
- Nominal outer sheath thickness: 3.0 mm
- Nominal outer diameter: 64.0 mm
- Maximum outer diameter: 68.48 mm
- Approximate weight: 11909 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
- Permissible current rating in open air: 522 A
- Permissible current rating when buried: 504 A
EX 5*25
Nexans ref. EX 006381 - Country ref. EX 5*25
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 25 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.9 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 24.0 mm
- Maximum outer diameter: 25.68 mm
- Approximate weight: 1381 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 127 A
- Permissible current rating when buried: 141 A
EX 5*35
Nexans ref. EX 006391 - Country ref. EX 5*35
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 35 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.9 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 27.0 mm
- Maximum outer diameter: 28.89 mm
- Approximate weight: 1828 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 157 A
- Permissible current rating when buried: 170 A
EX 5*4
Nexans ref. EX 006341 - Country ref. EX 5*4
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 4 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 14.0 mm
- Maximum outer diameter: 14.98 mm
- Approximate weight: 326 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 40 A
- Permissible current rating when buried: 51 A
EX 5*400
Nexans ref. EX 000717 - Country ref. EX 5*400
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 400 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 2.0 mm
- Nominal outer sheath thickness: 3.5 mm
- Nominal outer diameter: 80.0 mm
- Maximum outer diameter: 85.6 mm
- Approximate weight: 19035 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
- Permissible current rating in open air: 695 A
- Permissible current rating when buried: 657 A
EX 5*4RE
Nexans ref. EX 006331 - Country ref. EX 5*4RE
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular solid (RE)
- Number of conductors: 5
- Conductor cross-section: 4 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 14.0 mm
- Maximum outer diameter: 14.98 mm
- Approximate weight: 315 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 40 A
- Permissible current rating when buried: 51 A
EX 5*50
Nexans ref. EX 006401 - Country ref. EX 5*50
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 50 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 31.0 mm
- Maximum outer diameter: 33.17 mm
- Approximate weight: 2484 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 190 A
- Permissible current rating when buried: 204 A
EX 5*6
Nexans ref. EX 006351 - Country ref. EX 5*6
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 6 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 15.5 mm
- Maximum outer diameter: 16.59 mm
- Approximate weight: 435 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 52 A
- Permissible current rating when buried: 64 A
EX 5*6RE
Nexans ref. EX 006012 - Country ref. EX 5*6RE
- Conductor flexibility: Solid class 1
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 6 mm²
- Conductor diameter: 2.3 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 14.5 mm
- Maximum outer diameter: 15.5 mm
- Approximate weight: 440 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 58 A
- Permissible current rating when buried: 74 A
EX 5*70
Nexans ref. EX 006411 - Country ref. EX 5*70
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 70 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.1 mm
- Nominal outer sheath thickness: 2.1 mm
- Nominal outer diameter: 36.0 mm
- Maximum outer diameter: 38.52 mm
- Approximate weight: 3511 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 242 A
- Permissible current rating when buried: 252 A
EX 5*95
Nexans ref. EX 006421 - Country ref. EX 5*95
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 95 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 1.1 mm
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 41.0 mm
- Maximum outer diameter: 43.87 mm
- Approximate weight: 4745 kg/km
- Number of cores: 5
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating in open air: 293 A
- Permissible current rating when buried: 302 A
EX 6*1.5 NEW
Nexans ref. EX 005617 - Country ref. EX 6*1.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 6
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 12.0 mm
- Maximum outer diameter: 12.84 mm
- Approximate weight: 193 kg/km
- Number of cores: 6
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EX 6*2.5
Nexans ref. EX 006017 - Country ref. EX 6*2.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 6
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 1.9 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 13.5 mm
- Maximum outer diameter: 14.45 mm
- Approximate weight: 262 kg/km
- Number of cores: 6
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 46 A
EX 7*1.5
Nexans ref. EX 005623 - Country ref. EX 7*1.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 7
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 12.0 mm
- Maximum outer diameter: 12.84 mm
- Approximate weight: 208 kg/km
- Number of cores: 7
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EX 7*2.5
Nexans ref. EX 006026 - Country ref. EX 7*2.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 7
- Conductor cross-section: 2.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 13.5 mm
- Maximum outer diameter: 14.45 mm
- Approximate weight: 283 kg/km
- Number of cores: 7
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 46 A
EX 7*4
Nexans ref. EX 006343 - Country ref. EX 7*4
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 7
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.43 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 15.0 mm
- Maximum outer diameter: 16.0 mm
- Approximate weight: 395 kg/km
- Number of cores: 7
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 45 A
- Permissible current rating when buried: 59 A
EX 8*1.5 NEW
Nexans ref. EX 001707 - Country ref. EX 8*1.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 8
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 13.0 mm
- Maximum outer diameter: 13.91 mm
- Approximate weight: 239 kg/km
- Number of cores: 8
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EX 8*2.5
Nexans ref. EX 004756 - Country ref. EX 8*2.5
- Packaging: Drum (m)
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 8
- Conductor cross-section: 2.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 14.5 mm
- Maximum outer diameter: 15.52 mm
- Approximate weight: 325 kg/km
- Number of cores: 8
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 46 A
EX 9*1.5
Nexans ref. EX 005639 - Country ref. EX 9*1.5
- Conductor flexibility: Class 2 IEC 60228
- Conductor shape: Circular
- Number of conductors: 9
- Conductor cross-section: 1.5 mm²
- Conductor diameter: - mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 14.4 mm
- Maximum outer diameter: 15.41 mm
- Approximate weight: 274 kg/km
- Number of cores: 9
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
Description
Description
Standards
-
ProductIEC 60228; IEC 60502-1
-
TestIEC 60332-1-2
Scope
This specification covers XLPE insulated, circular or shaped, multicore unarmoured cables, rated at 0.6/1 KV according to IEC 60502-1 for use indoors, outdoors, and in cable ducts.
Construction
2.1 Conductor
Plain, annealed electrolytic copper conductors, circular stranded, or sectoral stranded, conforming to the applicable requirements of IEC 60228.
2.2 Insulation
XLPE material, conforming to the applicable requirements of IEC 60502-1.
2.3 Assembly
Insulated conductors are laid up, filled where necessary with non-hygroscopic material.
2.4 Sheath
PVC based thermoplastic material, conforming to the applicable requirements of IEC 60502-1.
2.5 TESTS
Conforming to the applicable requirements of IEC 60502-1 either on Raw materials or on finished products.
TEST AT WORKS unarmored multicore
Routine Tests
- Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag. 15.1 & 15.2
- Voltage test acc. to IEC 60502-1 parag. 15.1 & 15.3
Liban Cables will carry out these tests on all the lengths and tests certificates will be provided .
Sample Tests
- Check of the build - up and color coding of the cable
- Check of dimensions
Insulation : according to IEC 60502-1 Parag. 16.5.2
Oversheath : according to IEC 60502-1 Parag. 16.5.3
These tests will be carried out on one length of each size during each inspection .
Tests certificates will be provided by Liban Cables
Type Tests
Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-1.
These tests will be carried out on one length of the order .
Tests certificates will be provided by Liban Cables
DRAWING LV UNARMORED CIRCULAR CONDUCTORS
DRAWING LV UNARMORED SHAPED CONDUCTORS
Cable identification - LV cables ≤ 1KV
INSULATION COLORS:
|
|
Neutral |
Cond.1 |
Cond.2 |
Cond.3 |
Cond.4 |
|
1 Conductor |
|
BLACK |
|
|
|
|
2 Conductors |
GREY |
BLACK |
|
|
|
|
3 Conductors |
|
BLACK |
RED |
BLUE |
|
|
4 Conductors |
GREY |
BLACK |
RED |
BLUE |
|
|
5 Conductors |
GREY |
BLACK |
RED |
BLUE |
GREEN |
All numbered control cables (6 conductors and above), are insulated with white color, and numbered with black digits
CABLE MARKING OVER THE OUTER JACKET (by inkjet printing):
LIBAN CABLES DESCRIPTION RATED VOLTAGE SECTION MM2 Year of manufacture meter marking
Other cable identification requirements are available upon request
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania