Armored , Halogen free, Low smoke, Fire & UV resistant Multicore cables
Armored , Halogen free, Low smoke, Fire & UV resistant Multicore cables
0.6/1kv POWER CABLES conforming to IEC 60502-1 & IEC 60331
Read moreSFC2XGU 4*300
Nexans ref. SFC2XGU 001375 - Country ref. SFC2XGU 4*300//CEI-UV
- Number of conductors: 4
- Armour type: Galvanized steel tapes
- Conductor cross-section: 300 mm²
- Nominal insulation thickness: 1.8 mm
- Nominal armour wire diameter: 0.5 mm
- Nominal outer sheath thickness: 3.1 mm
- Nominal overall diameter: 71.0 mm
- Approximate weight: 15028 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
SFC2XRU 2*2.5
Nexans ref. SFC2XRU008208 - Country ref. SFC2XRU 2*2.5//CEI-UV
- Number of conductors: 2
- Armour type: Galvanized steel wires
- Conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 15.5 mm
- Approximate weight: 421 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
SFC2XRU 3*10
Nexans ref. SFC2XRU008205 - Country ref. SFC2XRU 3*10//CEI-UV
- Number of conductors: 3
- Armour type: Galvanized steel wires
- Conductor cross-section: 10 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 21.0 mm
- Approximate weight: 936 kg/km
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
SFC2XRU 3*16
Nexans ref. SFC2XRU008204 - Country ref. SFC2XRU 3*16//CEI-UV
- Number of conductors: 3
- Armour type: Galvanized steel wires
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 23.0 mm
- Approximate weight: 1196 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
SFC2XRU 3*2.5
Nexans ref. SFC2XRU000062 - Country ref. SFC2XRU 3*2.5//CEI-UV
- Number of conductors: 3
- Armour type: Galvanized steel wires
- Conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 16.0 mm
- Approximate weight: 458 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
SFC2XRU 3*25
Nexans ref. SFC2XRU008203 - Country ref. SFC2XRU 3*25//CEI-UV
- Number of conductors: 3
- Armour type: Galvanized steel wires
- Conductor cross-section: 25 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 27.0 mm
- Approximate weight: 1769 kg/km
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
SFC2XRU 3*4
Nexans ref. SFC2XRU008207 - Country ref. SFC2XRU 3*4//CEI-UV
- Number of conductors: 3
- Armour type: Galvanized steel wires
- Conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 17.5 mm
- Approximate weight: 544 kg/km
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
SFC2XRU 3*50
Nexans ref. SFC2XRU008101 - Country ref. SFC2XRU 3*50//CEI-UV
- Number of conductors: 3
- Armour type: Galvanized steel wires
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal overall diameter: 33.0 mm
- Approximate weight: 2736 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
SFC2XRU 3*6
Nexans ref. SFC2XRU008206 - Country ref. SFC2XRU 3*6//CEI-UV
- Number of conductors: 3
- Armour type: Galvanized steel wires
- Conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 18.0 mm
- Approximate weight: 631 kg/km
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
SFC2XRU 4*10
Nexans ref. SFC2XRU006007 - Country ref. SFC2XRU 4*10//CEI-UV
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 10 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 2.0 mm
- Approximate weight: 1086 kg/km
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
SFC2XRU 4*120
Nexans ref. SFC2XRU006017 - Country ref. SFC2XRU 4*120//CEI-1UV
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 120 mm²
- Nominal insulation thickness: 1.2 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 2.5 mm
- Nominal overall diameter: 52.0 mm
- Approximate weight: 7857 kg/km
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
SFC2XRU 4*16
Nexans ref. SFC2XRU006001 - Country ref. SFC2XRU 4*16//CEI-UV
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 25.0 mm
- Approximate weight: 1530 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
SFC2XRU 4*2.5
Nexans ref. SFC2XRU001318 - Country ref. SFC2XRU 4*2.5//CEI-UV
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 17.0 mm
- Approximate weight: 516 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
SFC2XRU 4*25
Nexans ref. SFC2XRU006009 - Country ref. SFC2XRU 4*25//CEI-UV
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 25 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 29.0 mm
- Approximate weight: 2097 kg/km
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
SFC2XRU 4*35
Nexans ref. SFC2XRU006015 - Country ref. SFC2XRU 4*35//CEI-UV
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal overall diameter: 32.0 mm
- Approximate weight: 2619 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
SFC2XRU 4*4
Nexans ref. SFC2XRU000371 - Country ref. SFC2XRU 4*4//CEI-UV
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 18.5 mm
- Approximate weight: 619 kg/km
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
SFC2XRU 4*50
Nexans ref. SFC2XRU006011 - Country ref. SFC2XRU 4*50//CEI-UV
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 2.0 mm
- Nominal overall diameter: 36.0 mm
- Approximate weight: 3332 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
SFC2XRU 4*6
Nexans ref. SFC2XRU004006 - Country ref. SFC2XRU 4*6//CEI-UV
- Number of conductors: 4
- Armour type: Galvanized steel wires
- Conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 22.0 mm
- Approximate weight: 950 kg/km
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
SFC2XRU 5*16
Nexans ref. SFC2XRU000803 - Country ref. SFC2XRU 5*16//CEI-UV
- Number of conductors: 5
- Armour type: Galvanized steel wires
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 27.0 mm
- Approximate weight: 1788 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
Description
Description
Standards
-
ProductIEC 60502-1
-
TestIEC 60331-1 or 2
Construction
1- Conductors
stranded-class 2 according to IEC 60228
2 - Mica tape
MICA/GLASS FIRE RESISTANT TAPE
3 - Insulation
XLPE
4 - Assembly
Insulated conductors are laid up, filled where necessary with non-hygroscopic material and covered with an extruded thickness of thermoplastic material.
5 - Armour
Galvanized round wires or steel tapes completely covering the assembly of cores complying to the applicable requirements of IEC 60502-1.
6 - Outer sheath
Low Smoke Zero Halogen compound, Color as per customer requirement
7 - Packing
Drums can be wooden or steel
TEST AT WORKS FIRE RESISTANT ARMORED
Routine Tests
- Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag.15.1&15.2
- Voltage test acc. to IEC 60502-1 parag. 15.1&15.3
Liban Cables will carry out these tests on all the lengths and tests certificates will be provided
Sample Tests
- Check of the build - up and color coding of the cable
- Check of dimensions
Insulation : according to IEC 60502-1 Parag. 16.5.2
Armour : according to IEC 60502-1 Parag. 16.7
Oversheath : according to IEC 60502-1 Parag. 16.5.3
- Hot Set Test for XLPE insulation according to IEC 60502-1 Parag. 16.9
These tests will be carried out on one length of each size during each inspection .
Tests certificates will be provided by Liban Cables.
Type Tests
Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-1.
Fire Resistance test according to IEC 60331-21 (750۫C for 90 mins) :
- 500V between conductors
- 300V between cond. & earth
These tests will be carried out on one length of the order.
Tests certificates will be provided by Liban Cables
DRAWING FIRE RESISTANT ARMORED CABLES
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics