- Products
- Your Business
- Newsroom
- Tools & Resources
- About us
- CSR
- People & Careers
- Search
- Contact us
- Compare
- Sign in
AL, Single core AWA Armored, XLPE insulated, PVC sheathed
AL, Single core AWA Armored, XLPE insulated, PVC sheathed
0.6 / 1 KV POWER CABLES
Conforming to IEC 60502-1
EAXW 1*120
Nexans ref. EAXW 000300 - Country ref. EAXW 1*120
- Conductor cross-section: 120 mm²
- Nominal insulation thickness: 1.2 mm
- Nominal armour wire diameter: 1.7 mm
- Nominal outer sheath thickness: 1.7 mm
- Nominal outer diameter: 23.0 mm
- Approximate weight: 748 kg/km
- Max. DC resistance of the conductor at 20°C: 0.253 Ohm/km
- Permissible current rating in open air: 299 A
- Permissible current rating when buried: 283 A
EAXW 1*150
Nexans ref. EAXW 000640 - Country ref. EAXW 1*150
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 1.4 mm
- Nominal armour wire diameter: 1.7 mm
- Nominal outer sheath thickness: 1.7 mm
- Nominal outer diameter: 25.0 mm
- Approximate weight: 868 kg/km
- Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
- Permissible current rating in open air: 344 A
- Permissible current rating when buried: 316 A
EAXW 1*185
Nexans ref. EAXW 000650 - Country ref. EAXW 1*185
- Conductor cross-section: 185 mm²
- Nominal insulation thickness: 1.6 mm
- Nominal armour wire diameter: 1.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 28.0 mm
- Approximate weight: 1070 kg/km
- Max. DC resistance of the conductor at 20°C: 0.164 Ohm/km
- Permissible current rating in open air: 392 A
- Permissible current rating when buried: 356 A
EAXW 1*240
Nexans ref. EAXW 000660 - Country ref. EAXW 1*240
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 1.7 mm
- Nominal armour wire diameter: 1.7 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 30.0 mm
- Approximate weight: 1265 kg/km
- Max. DC resistance of the conductor at 20°C: 0.125 Ohm/km
- Permissible current rating in open air: 461 A
- Permissible current rating when buried: 413 A
EAXW 1*300
Nexans ref. EAXW 000661 - Country ref. EAXW 1*300
- Conductor cross-section: 300 mm²
- Nominal insulation thickness: 1.8 mm
- Nominal armour wire diameter: 1.7 mm
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 32.0 mm
- Approximate weight: 1504 kg/km
- Max. DC resistance of the conductor at 20°C: 0.1 Ohm/km
- Permissible current rating in open air: 525 A
- Permissible current rating when buried: 468 A
EAXW 1*400
Nexans ref. EAXW 000672 - Country ref. EAXW 1*400
- Conductor cross-section: 400 mm²
- Nominal insulation thickness: 2.0 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer sheath thickness: 2.1 mm
- Nominal outer diameter: 31.5 mm
- Approximate weight: 1939 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0778 Ohm/km
- Permissible current rating in open air: 613 A
- Permissible current rating when buried: 538 A
EAXW 1*500
Nexans ref. EAXW 000673 - Country ref. EAXW 1*500
- Conductor cross-section: 500 mm²
- Nominal insulation thickness: 2.2 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 40.0 mm
- Approximate weight: 2360 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0605 Ohm/km
- Permissible current rating in open air: 687 A
- Permissible current rating when buried: 608 A
EAXW 1*630
Nexans ref. EAXW 000132 - Country ref. EAXW 1*630
- Conductor cross-section: 630 mm²
- Nominal insulation thickness: 2.4 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer sheath thickness: 2.3 mm
- Nominal outer diameter: 45.0 mm
- Approximate weight: 2895 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0469 Ohm/km
- Permissible current rating in open air: 782 A
- Permissible current rating when buried: 686 A
EAXW 1*70
Nexans ref. EAXW 000643 - Country ref. EAXW 1*70
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal armour wire diameter: 1.7 mm
- Nominal outer sheath thickness: 1.6 mm
- Nominal outer diameter: 19.5 mm
- Approximate weight: 520 kg/km
- Max. DC resistance of the conductor at 20°C: 0.443 Ohm/km
- Permissible current rating in open air: 213 A
- Permissible current rating when buried: 206 A
EAXW 1*95
Nexans ref. EAXW 000620 - Country ref. EAXW 1*95
- Conductor cross-section: 95 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal armour wire diameter: 1.7 mm
- Nominal outer sheath thickness: 1.6 mm
- Nominal outer diameter: 22.0 mm
- Approximate weight: 542 kg/km
- Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
- Permissible current rating in open air: 258 A
- Permissible current rating when buried: 247 A
Description
Description
Standards
-
ProductIEC 60228; IEC 60502-1
-
TestIEC 60332-1-2
Scope
This specification covers XLPE insulated, circular, single core armoured cables, rated at 0.6/1 KV according to IEC 60502-1 for use indoors, outdoors, in cable ducts and for direct burial underground, where severe mechanical stresses are present.
Construction
2.1 Conductor
Aluminum conductors, circular stranded, conforming to the applicable requirements of IEC 60228.
2.2 Insulation
XLPE thermosetting material, conforming to the applicable requirements of IEC 60502-1.
2.3 Armour
Aluminum wires armoring complying to the applicable requirements of IEC 60502-1.
2.4 Sheath
PVC based thermoplastic material, conforming to the applicable requirements of IEC 60502-1.
Tests
Conforming to the applicable requirements of IEC 60502-1 either on Raw materials or on finished products.
TEST AT WORKS according to IEC 60502-1 armored
Routine Tests
- Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag. 15.1 & 15.2
- Voltage test acc. to IEC 60502-1 parag. 15.1 & 15.3
Liban Cables will carry out these tests on all the lengths and tests certificates will be provided.
Sample Tests
- Check of the build - up and color coding of the cable
- Check of dimensions
Insulation: according to IEC 60502-1 Parag. 16.5.2
Armour: according to IEC 60502-1 Parag. 16.7
Oversheath: according to IEC 60502-1 Parag. 16.5.3
These tests will be carried out on one length of each size during each inspection .
Tests certificates will be provided by Liban Cables
Type Tests
Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-1.
These tests will be carried out on one length of the order .
Tests certificates will be provided by Liban Cables
Cable identification - LV cables ≤ 1KV
INSULATION COLORS:
|
Neutral |
Cond.1 |
Cond.2 |
Cond.3 |
Cond.4 |
1 Conductor |
|
BLACK |
|
|
|
2 Conductors |
GREY |
BLACK |
|
|
|
3 Conductors |
|
BLACK |
RED |
BLUE |
|
4 Conductors |
GREY |
BLACK |
RED |
BLUE |
|
5 Conductors |
GREY |
BLACK |
RED |
BLUE |
GREEN |
All numbered control cables (6 conductors and above), are insulated with white color, and numbered with black digits
CABLE MARKING OVER THE OUTER JACKET (by inkjet printing):
LIBAN CABLES DESCRIPTION RATED VOLTAGE SECTION MM2 Year of manufacture meter marking
Other cable identification requirements are available upon request
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Find a Distributor
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania