EAXT - ABC cables with Messenger 54.6 mm² with street lighting

Products

EAXT 3*25+54.6+16//EDL-SP

Nexans ref. EAXT 004922 - Country ref. EAXT 3*25+54.6+16//EDL-SP

  • Number of conductors: 5
  • Phase Conductor Cross Section: 70 mm²
  • Nominal insulation thickness: 0.7 mm
  • Conductor cross-section: 25 mm²
  • Insulation thickness of smaller conductor: 1.2 mm
  • Nominal overall diameter: 30.0 mm
  • Approximate weight: 563 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.2 Ohm/km
  • Perm current rating in air 30°C: - A
  • Max. linear resistance, public lighting conductor: 1.91 Ohm/km
  • Permanent current rating, public lighting in air a 30°C: - A

 

EAXT 3*25+54.6+2*16//E

Nexans ref. EAXT 000223 - Country ref. EAXT 3*25+54.6+2*16//E

  • Number of conductors: 6
  • Phase Conductor Cross Section: 70 mm²
  • Nominal insulation thickness: 1.4 mm
  • Conductor cross-section: 25 mm²
  • Insulation thickness of smaller conductor: 1.2 mm
  • Nominal overall diameter: 30.0 mm
  • Approximate weight: 626 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.2 Ohm/km
  • Perm current rating in air 30°C: 111 A
  • Max. linear resistance, public lighting conductor: 1.91 Ohm/km
  • Permanent current rating, public lighting in air a 30°C: 83 A

 

EAXT 3*35+54.6+16//E

Nexans ref. EAXT 000225 - Country ref. EAXT 3*35+54.6+16//E

  • Number of conductors: 5
  • Phase Conductor Cross Section: 35 mm²
  • Nominal insulation thickness: 1.6 mm
  • Conductor cross-section: 16 mm²
  • Insulation thickness of smaller conductor: 1.2 mm
  • Nominal overall diameter: 32.0 mm
  • Approximate weight: 685 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.868 Ohm/km
  • Perm current rating in air 30°C: 138 A
  • Max. linear resistance, public lighting conductor: 1.91 Ohm/km
  • Permanent current rating, public lighting in air a 30°C: 83 A

 

EAXT 3*35+54.6+16//EDL-SP

Nexans ref. EAXT 004923 - Country ref. EAXT 3*35+54.6+16//EDL-SP

  • Number of conductors: 5
  • Phase Conductor Cross Section: 35 mm²
  • Nominal insulation thickness: 1.6 mm
  • Conductor cross-section: 16 mm²
  • Insulation thickness of smaller conductor: 1.2 mm
  • Nominal overall diameter: 32.0 mm
  • Approximate weight: 685 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.868 Ohm/km
  • Perm current rating in air 30°C: 138 A
  • Max. linear resistance, public lighting conductor: 1.91 Ohm/km
  • Permanent current rating, public lighting in air a 30°C: 83 A

 

EAXT 3*35+54.6+2*16//AFR

Nexans ref. EAXT 000582 - Country ref. EAXT 3*35+54.6+2*16//AFR

  • Number of conductors: 6
  • Phase Conductor Cross Section: 35 mm²
  • Nominal insulation thickness: 0.7 mm
  • Conductor cross-section: 16 mm²
  • Insulation thickness of smaller conductor: 1.2 mm
  • Nominal overall diameter: 32.0 mm
  • Approximate weight: 736 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.2 Ohm/km
  • Perm current rating in air 30°C: 138 A
  • Max. linear resistance, public lighting conductor: 1.91 Ohm/km
  • Permanent current rating, public lighting in air a 30°C: 83 A

 

EAXT 3*35+54.6+2*16//E

Nexans ref. EAXT 004041 - Country ref. EAXT 3*35+54.6+2*16//E

  • Number of conductors: 6
  • Phase Conductor Cross Section: 35 mm²
  • Nominal insulation thickness: 1.6 mm
  • Conductor cross-section: 16 mm²
  • Insulation thickness of smaller conductor: 1.2 mm
  • Nominal overall diameter: 32.0 mm
  • Approximate weight: 733 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.868 Ohm/km
  • Perm current rating in air 30°C: 138 A
  • Max. linear resistance, public lighting conductor: 1.91 Ohm/km
  • Permanent current rating, public lighting in air a 30°C: 83 A

 

EAXT 3*50+54.6+16//E

Nexans ref. EAXT 000248 - Country ref. EAXT 3*50+54.6+16//E

  • Number of conductors: 5
  • Phase Conductor Cross Section: 50 mm²
  • Nominal insulation thickness: 1.6 mm
  • Conductor cross-section: 16 mm²
  • Insulation thickness of smaller conductor: 1.2 mm
  • Nominal overall diameter: 34.0 mm
  • Approximate weight: 792 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.641 Ohm/km
  • Perm current rating in air 30°C: 168 A
  • Max. linear resistance, public lighting conductor: 1.91 Ohm/km
  • Permanent current rating, public lighting in air a 30°C: 83 A

 

EAXT 3*50+54.6+16//EDL-SP

Nexans ref. EAXT 004918 - Country ref. EAXT 3*50+54.6+16//EDL-SP

  • Number of conductors: 5
  • Phase Conductor Cross Section: 50 mm²
  • Nominal insulation thickness: 1.6 mm
  • Conductor cross-section: 16 mm²
  • Insulation thickness of smaller conductor: 1.2 mm
  • Nominal overall diameter: 34.0 mm
  • Approximate weight: 792 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.641 Ohm/km
  • Perm current rating in air 30°C: 168 A
  • Max. linear resistance, public lighting conductor: 1.91 Ohm/km
  • Permanent current rating, public lighting in air a 30°C: 83 A

 

EAXT 3*50+54.6+2*16//E

Nexans ref. EAXT 004042 - Country ref. EAXT 3*50+54.6+2*16//E

  • Number of conductors: 6
  • Phase Conductor Cross Section: 50 mm²
  • Nominal insulation thickness: 1.6 mm
  • Conductor cross-section: 50 mm²
  • Insulation thickness of smaller conductor: 1.2 mm
  • Nominal overall diameter: 34.5 mm
  • Approximate weight: 854 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.2 Ohm/km
  • Perm current rating in air 30°C: 213 A
  • Max. linear resistance, public lighting conductor: 1.91 Ohm/km
  • Permanent current rating, public lighting in air a 30°C: 83 A

 

EAXT 3*70+54.6+16//E

Nexans ref. EAXT 000353 - Country ref. EAXT 3*70+54.6+16//E

  • Number of conductors: 5
  • Phase Conductor Cross Section: 70 mm²
  • Nominal insulation thickness: 1.8 mm
  • Conductor cross-section: 16 mm²
  • Insulation thickness of smaller conductor: 1.2 mm
  • Nominal overall diameter: 37.0 mm
  • Approximate weight: 993 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.443 Ohm/km
  • Perm current rating in air 30°C: 213 A
  • Max. linear resistance, public lighting conductor: 1.91 Ohm/km
  • Permanent current rating, public lighting in air a 30°C: 83 A

 

EAXT 3*70+54.6+16//EDL-SP

Nexans ref. EAXT 004920 - Country ref. EAXT 3*70+54.6+16//EDL-SP

  • Number of conductors: 5
  • Phase Conductor Cross Section: 70 mm²
  • Nominal insulation thickness: 1.8 mm
  • Conductor cross-section: 16 mm²
  • Insulation thickness of smaller conductor: 1.2 mm
  • Nominal overall diameter: 37.0 mm
  • Approximate weight: 993 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.443 Ohm/km
  • Perm current rating in air 30°C: 213 A
  • Max. linear resistance, public lighting conductor: 1.91 Ohm/km
  • Permanent current rating, public lighting in air a 30°C: 83 A

 

EAXT 3*70+54.6+16//KAD

Nexans ref. EAXT 000370 - Country ref. EAXT 3*70+54.6+16//KAD

  • Number of conductors: 5
  • Phase Conductor Cross Section: 70 mm²
  • Nominal insulation thickness: 1.8 mm
  • Conductor cross-section: 16 mm²
  • Insulation thickness of smaller conductor: 1.2 mm
  • Nominal overall diameter: 37.0 mm
  • Approximate weight: 993 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.443 Ohm/km
  • Perm current rating in air 30°C: 213 A
  • Max. linear resistance, public lighting conductor: 1.91 Ohm/km
  • Permanent current rating, public lighting in air a 30°C: 83 A

 

EAXT 3*70+54.6+2*16//AFR

Nexans ref. EAXT 000580 - Country ref. EAXT 3*70+54.6+2*16//AFR

  • Number of conductors: 6
  • Phase Conductor Cross Section: 70 mm²
  • Nominal insulation thickness: 1.8 mm
  • Conductor cross-section: 70 mm²
  • Insulation thickness of smaller conductor: 1.2 mm
  • Nominal overall diameter: 38.0 mm
  • Approximate weight: 1048 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.2 Ohm/km
  • Perm current rating in air 30°C: 213 A
  • Max. linear resistance, public lighting conductor: 1.91 Ohm/km
  • Permanent current rating, public lighting in air a 30°C: 83 A

 

EAXT 3*70+54.6+2*16//E

Nexans ref. EAXT 004047 - Country ref. EAXT 3*70+54.6+2*16//E

  • Number of conductors: 6
  • Phase Conductor Cross Section: 70 mm²
  • Nominal insulation thickness: 1.8 mm
  • Conductor cross-section: 70 mm²
  • Insulation thickness of smaller conductor: 1.2 mm
  • Nominal overall diameter: 38.0 mm
  • Approximate weight: 1048 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.2 Ohm/km
  • Perm current rating in air 30°C: 213 A
  • Max. linear resistance, public lighting conductor: 1.91 Ohm/km
  • Permanent current rating, public lighting in air a 30°C: 83 A

 

EAXT 3*70+54.6+25

Nexans ref. EAXT 000688 - Country ref. EAXT 3*70+54.6+25

  • Number of conductors: 5
  • Phase Conductor Cross Section: 70 mm²
  • Nominal insulation thickness: 1.8 mm
  • Conductor cross-section: 25 mm²
  • Insulation thickness of smaller conductor: 1.4 mm
  • Nominal overall diameter: 38.0 mm
  • Approximate weight: 1025 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.443 Ohm/km
  • Perm current rating in air 30°C: 213 A
  • Max. linear resistance, public lighting conductor: 1.2 Ohm/km
  • Permanent current rating, public lighting in air a 30°C: 111 A

 

EAXT 3*95+54.6+16//E

Nexans ref. EAXT 000373 - Country ref. EAXT 3*95+54.6+16//E

  • Number of conductors: 5
  • Phase Conductor Cross Section: 95 mm²
  • Nominal insulation thickness: 1.8 mm
  • Conductor cross-section: 16 mm²
  • Insulation thickness of smaller conductor: 1.2 mm
  • Nominal overall diameter: 40.0 mm
  • Approximate weight: 1240 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
  • Perm current rating in air 30°C: 258 A
  • Max. linear resistance, public lighting conductor: 1.91 Ohm/km
  • Permanent current rating, public lighting in air a 30°C: 83 A

 

EAXT 3*95+54.6+2*16//E

Nexans ref. EAXT 000375 - Country ref. EAXT 3*95+54.6+2*16//E

  • Number of conductors: 6
  • Phase Conductor Cross Section: 95 mm²
  • Nominal insulation thickness: 1.8 mm
  • Conductor cross-section: 16 mm²
  • Insulation thickness of smaller conductor: 1.2 mm
  • Nominal overall diameter: 41.5 mm
  • Approximate weight: 1315 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
  • Perm current rating in air 30°C: 258 A
  • Max. linear resistance, public lighting conductor: 1.91 Ohm/km
  • Permanent current rating, public lighting in air a 30°C: 83 A

 

Description

Description

Standards

  • International
    IEC 60502-1
  • National
    NF C33-209

Application

Network distribution bundled conductors with neutral messenger are designed for rural and urban areas.

Some important cable characteristics are :

  • Ultraviolet radiation resistance,
  • Ozone resistance,
  • High dielectric strength,
  • Light weight and easy to handle.
  • Anti-theft cables

 

Installation

These cables are NOT ALLOWED to be buried, even in conduits.

They are intended for aerial use only.

 

Description

The bundled conductor cables have aluminum conductors, insulated with XLPE, they have good durability and thermal resistance.

 

Messenger/Neutral characteristics

  • core : circular stranded aluminum alloy, cross section area 54.6 mm²
  • Insulation : Black XLPE
  • nominal cross section : 54.6 mm²

 

Street lighting conductor characteristics (smaller conductor)

  • core : circular stranded aluminum, cross section area 16 or 25 mm²
  • Insulation : Black XLPE
  • nominal cross section : 16 or 25 mm²

 

Electrical characteristics

  • Rated voltage : 0.6/1 kV

TEST AT WORKS for ABC cables

  Routine Tests

 - Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag. 15.1 & 15.2

 - Spark Test for conductors

Liban Cables will carry out these tests on all the lengths and tests certificates will be provided.

 

Sample Tests

 - Check of the build - up and color coding of the cable

 - Check of dimensions: Insulation: according to IEC 60502-1 Parag.  16.5.2

 - Hot Set Test: according to IEC 60502-1 Parag.  16.9

 These tests will be carried out on one length during  of each size during each inspection .

Tests certificates will be provided by Liban Cables

                                                                       

Type Tests

Mechanical characteristics on insulation material (tensile strength and elongation at break) in accordance with IEC 60502-1.

These tests will be carried out on one length of the order

Tests certificates will be provided by Liban Cables

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Class 2 IEC 60228
Conductor material
Aluminum
Messenger
Aluminium alloy
Insulation
XLPE
Colour
Black
Conductor shape
Circular

Dimensional characteristics

Dimensional characteristics

Messenger cross-section
54.6 mm²
Messenger insulation thickness
1.6 mm

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV
Resistance of neutral conductor at 20ºC
0.63 Ohm/km

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close