EAXT - ABC cables with Messenger 54.6 mm² with street lighting
EAXT - ABC cables with Messenger 54.6 mm² with street lighting
Generally to NF C 33-209 and testing to IEC 60502-1
Read moreEAXT 3*25+54.6+16//EDL-SP
Nexans ref. EAXT 004922 - Country ref. EAXT 3*25+54.6+16//EDL-SP
- Number of conductors: 5
- Phase Conductor Cross Section: 70 mm²
- Nominal insulation thickness: 0.7 mm
- Conductor cross-section: 25 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal overall diameter: 30.0 mm
- Approximate weight: 563 kg/km
- Max. DC resistance of the conductor at 20°C: 1.2 Ohm/km
- Perm current rating in air 30°C: - A
- Max. linear resistance, public lighting conductor: 1.91 Ohm/km
- Permanent current rating, public lighting in air a 30°C: - A
EAXT 3*25+54.6+2*16//E
Nexans ref. EAXT 000223 - Country ref. EAXT 3*25+54.6+2*16//E
- Number of conductors: 6
- Phase Conductor Cross Section: 70 mm²
- Nominal insulation thickness: 1.4 mm
- Conductor cross-section: 25 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal overall diameter: 30.0 mm
- Approximate weight: 626 kg/km
- Max. DC resistance of the conductor at 20°C: 1.2 Ohm/km
- Perm current rating in air 30°C: 111 A
- Max. linear resistance, public lighting conductor: 1.91 Ohm/km
- Permanent current rating, public lighting in air a 30°C: 83 A
EAXT 3*35+54.6+16//E
Nexans ref. EAXT 000225 - Country ref. EAXT 3*35+54.6+16//E
- Number of conductors: 5
- Phase Conductor Cross Section: 35 mm²
- Nominal insulation thickness: 1.6 mm
- Conductor cross-section: 16 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal overall diameter: 32.0 mm
- Approximate weight: 685 kg/km
- Max. DC resistance of the conductor at 20°C: 0.868 Ohm/km
- Perm current rating in air 30°C: 138 A
- Max. linear resistance, public lighting conductor: 1.91 Ohm/km
- Permanent current rating, public lighting in air a 30°C: 83 A
EAXT 3*35+54.6+16//EDL-SP
Nexans ref. EAXT 004923 - Country ref. EAXT 3*35+54.6+16//EDL-SP
- Number of conductors: 5
- Phase Conductor Cross Section: 35 mm²
- Nominal insulation thickness: 1.6 mm
- Conductor cross-section: 16 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal overall diameter: 32.0 mm
- Approximate weight: 685 kg/km
- Max. DC resistance of the conductor at 20°C: 0.868 Ohm/km
- Perm current rating in air 30°C: 138 A
- Max. linear resistance, public lighting conductor: 1.91 Ohm/km
- Permanent current rating, public lighting in air a 30°C: 83 A
EAXT 3*35+54.6+2*16//AFR
Nexans ref. EAXT 000582 - Country ref. EAXT 3*35+54.6+2*16//AFR
- Number of conductors: 6
- Phase Conductor Cross Section: 35 mm²
- Nominal insulation thickness: 0.7 mm
- Conductor cross-section: 16 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal overall diameter: 32.0 mm
- Approximate weight: 736 kg/km
- Max. DC resistance of the conductor at 20°C: 1.2 Ohm/km
- Perm current rating in air 30°C: 138 A
- Max. linear resistance, public lighting conductor: 1.91 Ohm/km
- Permanent current rating, public lighting in air a 30°C: 83 A
EAXT 3*35+54.6+2*16//E
Nexans ref. EAXT 004041 - Country ref. EAXT 3*35+54.6+2*16//E
- Number of conductors: 6
- Phase Conductor Cross Section: 35 mm²
- Nominal insulation thickness: 1.6 mm
- Conductor cross-section: 16 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal overall diameter: 32.0 mm
- Approximate weight: 733 kg/km
- Max. DC resistance of the conductor at 20°C: 0.868 Ohm/km
- Perm current rating in air 30°C: 138 A
- Max. linear resistance, public lighting conductor: 1.91 Ohm/km
- Permanent current rating, public lighting in air a 30°C: 83 A
EAXT 3*50+54.6+16//E
Nexans ref. EAXT 000248 - Country ref. EAXT 3*50+54.6+16//E
- Number of conductors: 5
- Phase Conductor Cross Section: 50 mm²
- Nominal insulation thickness: 1.6 mm
- Conductor cross-section: 16 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal overall diameter: 34.0 mm
- Approximate weight: 792 kg/km
- Max. DC resistance of the conductor at 20°C: 0.641 Ohm/km
- Perm current rating in air 30°C: 168 A
- Max. linear resistance, public lighting conductor: 1.91 Ohm/km
- Permanent current rating, public lighting in air a 30°C: 83 A
EAXT 3*50+54.6+16//EDL-SP
Nexans ref. EAXT 004918 - Country ref. EAXT 3*50+54.6+16//EDL-SP
- Number of conductors: 5
- Phase Conductor Cross Section: 50 mm²
- Nominal insulation thickness: 1.6 mm
- Conductor cross-section: 16 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal overall diameter: 34.0 mm
- Approximate weight: 792 kg/km
- Max. DC resistance of the conductor at 20°C: 0.641 Ohm/km
- Perm current rating in air 30°C: 168 A
- Max. linear resistance, public lighting conductor: 1.91 Ohm/km
- Permanent current rating, public lighting in air a 30°C: 83 A
EAXT 3*50+54.6+2*16//E
Nexans ref. EAXT 004042 - Country ref. EAXT 3*50+54.6+2*16//E
- Number of conductors: 6
- Phase Conductor Cross Section: 50 mm²
- Nominal insulation thickness: 1.6 mm
- Conductor cross-section: 50 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal overall diameter: 34.5 mm
- Approximate weight: 854 kg/km
- Max. DC resistance of the conductor at 20°C: 1.2 Ohm/km
- Perm current rating in air 30°C: 213 A
- Max. linear resistance, public lighting conductor: 1.91 Ohm/km
- Permanent current rating, public lighting in air a 30°C: 83 A
EAXT 3*70+54.6+16//E
Nexans ref. EAXT 000353 - Country ref. EAXT 3*70+54.6+16//E
- Number of conductors: 5
- Phase Conductor Cross Section: 70 mm²
- Nominal insulation thickness: 1.8 mm
- Conductor cross-section: 16 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal overall diameter: 37.0 mm
- Approximate weight: 993 kg/km
- Max. DC resistance of the conductor at 20°C: 0.443 Ohm/km
- Perm current rating in air 30°C: 213 A
- Max. linear resistance, public lighting conductor: 1.91 Ohm/km
- Permanent current rating, public lighting in air a 30°C: 83 A
EAXT 3*70+54.6+16//EDL-SP
Nexans ref. EAXT 004920 - Country ref. EAXT 3*70+54.6+16//EDL-SP
- Number of conductors: 5
- Phase Conductor Cross Section: 70 mm²
- Nominal insulation thickness: 1.8 mm
- Conductor cross-section: 16 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal overall diameter: 37.0 mm
- Approximate weight: 993 kg/km
- Max. DC resistance of the conductor at 20°C: 0.443 Ohm/km
- Perm current rating in air 30°C: 213 A
- Max. linear resistance, public lighting conductor: 1.91 Ohm/km
- Permanent current rating, public lighting in air a 30°C: 83 A
EAXT 3*70+54.6+16//KAD
Nexans ref. EAXT 000370 - Country ref. EAXT 3*70+54.6+16//KAD
- Number of conductors: 5
- Phase Conductor Cross Section: 70 mm²
- Nominal insulation thickness: 1.8 mm
- Conductor cross-section: 16 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal overall diameter: 37.0 mm
- Approximate weight: 993 kg/km
- Max. DC resistance of the conductor at 20°C: 0.443 Ohm/km
- Perm current rating in air 30°C: 213 A
- Max. linear resistance, public lighting conductor: 1.91 Ohm/km
- Permanent current rating, public lighting in air a 30°C: 83 A
EAXT 3*70+54.6+2*16//AFR
Nexans ref. EAXT 000580 - Country ref. EAXT 3*70+54.6+2*16//AFR
- Number of conductors: 6
- Phase Conductor Cross Section: 70 mm²
- Nominal insulation thickness: 1.8 mm
- Conductor cross-section: 70 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal overall diameter: 38.0 mm
- Approximate weight: 1048 kg/km
- Max. DC resistance of the conductor at 20°C: 1.2 Ohm/km
- Perm current rating in air 30°C: 213 A
- Max. linear resistance, public lighting conductor: 1.91 Ohm/km
- Permanent current rating, public lighting in air a 30°C: 83 A
EAXT 3*70+54.6+2*16//E
Nexans ref. EAXT 004047 - Country ref. EAXT 3*70+54.6+2*16//E
- Number of conductors: 6
- Phase Conductor Cross Section: 70 mm²
- Nominal insulation thickness: 1.8 mm
- Conductor cross-section: 70 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal overall diameter: 38.0 mm
- Approximate weight: 1048 kg/km
- Max. DC resistance of the conductor at 20°C: 1.2 Ohm/km
- Perm current rating in air 30°C: 213 A
- Max. linear resistance, public lighting conductor: 1.91 Ohm/km
- Permanent current rating, public lighting in air a 30°C: 83 A
EAXT 3*70+54.6+25
Nexans ref. EAXT 000688 - Country ref. EAXT 3*70+54.6+25
- Number of conductors: 5
- Phase Conductor Cross Section: 70 mm²
- Nominal insulation thickness: 1.8 mm
- Conductor cross-section: 25 mm²
- Insulation thickness of smaller conductor: 1.4 mm
- Nominal overall diameter: 38.0 mm
- Approximate weight: 1025 kg/km
- Max. DC resistance of the conductor at 20°C: 0.443 Ohm/km
- Perm current rating in air 30°C: 213 A
- Max. linear resistance, public lighting conductor: 1.2 Ohm/km
- Permanent current rating, public lighting in air a 30°C: 111 A
EAXT 3*95+54.6+16//E
Nexans ref. EAXT 000373 - Country ref. EAXT 3*95+54.6+16//E
- Number of conductors: 5
- Phase Conductor Cross Section: 95 mm²
- Nominal insulation thickness: 1.8 mm
- Conductor cross-section: 16 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal overall diameter: 40.0 mm
- Approximate weight: 1240 kg/km
- Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
- Perm current rating in air 30°C: 258 A
- Max. linear resistance, public lighting conductor: 1.91 Ohm/km
- Permanent current rating, public lighting in air a 30°C: 83 A
EAXT 3*95+54.6+2*16//E
Nexans ref. EAXT 000375 - Country ref. EAXT 3*95+54.6+2*16//E
- Number of conductors: 6
- Phase Conductor Cross Section: 95 mm²
- Nominal insulation thickness: 1.8 mm
- Conductor cross-section: 16 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal overall diameter: 41.5 mm
- Approximate weight: 1315 kg/km
- Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
- Perm current rating in air 30°C: 258 A
- Max. linear resistance, public lighting conductor: 1.91 Ohm/km
- Permanent current rating, public lighting in air a 30°C: 83 A
Description
Description
Standards
-
InternationalIEC 60502-1
-
NationalNF C33-209
Application
Network distribution bundled conductors with neutral messenger are designed for rural and urban areas.
Some important cable characteristics are :
- Ultraviolet radiation resistance,
- Ozone resistance,
- High dielectric strength,
- Light weight and easy to handle.
- Anti-theft cables
Installation
These cables are NOT ALLOWED to be buried, even in conduits.
They are intended for aerial use only.
Description
The bundled conductor cables have aluminum conductors, insulated with XLPE, they have good durability and thermal resistance.
Messenger/Neutral characteristics
- core : circular stranded aluminum alloy, cross section area 54.6 mm²
- Insulation : Black XLPE
- nominal cross section : 54.6 mm²
Street lighting conductor characteristics (smaller conductor)
- core : circular stranded aluminum, cross section area 16 or 25 mm²
- Insulation : Black XLPE
- nominal cross section : 16 or 25 mm²
Electrical characteristics
- Rated voltage : 0.6/1 kV
TEST AT WORKS for ABC cables
Routine Tests
- Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag. 15.1 & 15.2
- Spark Test for conductors
Liban Cables will carry out these tests on all the lengths and tests certificates will be provided.
Sample Tests
- Check of the build - up and color coding of the cable
- Check of dimensions: Insulation: according to IEC 60502-1 Parag. 16.5.2
- Hot Set Test: according to IEC 60502-1 Parag. 16.9
These tests will be carried out on one length during of each size during each inspection .
Tests certificates will be provided by Liban Cables
Type Tests
Mechanical characteristics on insulation material (tensile strength and elongation at break) in accordance with IEC 60502-1.
These tests will be carried out on one length of the order
Tests certificates will be provided by Liban Cables
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Resources
Resources
Documentation
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania