- Products
- Your Business
- Newsroom
- Tools & Resources
- About us
- CSR
- People & Careers
- Search
- Contact us
- Compare
- Sign in
Multicore (PN) STA Armored, XLPE insulated, PVC sheathed
Multicore (PN) STA Armored, XLPE insulated, PVC sheathed
0.6 / 1 KV POWER CABLES Conforming to IEC 60502-1
Read moreEXG 3*10+6 NEW
Nexans ref. EXG 005110 - Country ref. EXG 3*10+6
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 10 mm²
- Nominal insulation thickness: 0.7 mm
- Earth conductor cross section: 6 mm²
- Insulation thickness of smaller conductor: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Tape thickness: 0.2 mm
- Nominal outer diameter: 18.0 mm
- Approximate weight: 694 kg/km
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Resistance of neutral conductor at 20ºC: 3.08 Ohm/km
- Permissible current rating in open air: 71 A
- Permissible current rating when buried: 88 A
EXG 3*120+70SM
Nexans ref. EXG 005160 - Country ref. EXG 3*120+70SM
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 120 mm²
- Nominal insulation thickness: 1.1 mm
- Earth conductor cross section: 70 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal outer sheath thickness: 2.3 mm
- Tape thickness: 0.5 mm
- Nominal outer diameter: 41.0 mm
- Approximate weight: 5064 kg/km
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.268 Ohm/km
- Permissible current rating in open air: 339 A
- Permissible current rating when buried: 345 A
EXG 3*150+70SM
Nexans ref. EXG 005170 - Country ref. EXG 3*150+70SM
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 1.4 mm
- Earth conductor cross section: 70 mm²
- Insulation thickness of smaller conductor: 1.1 mm
- Nominal outer sheath thickness: 2.4 mm
- Tape thickness: 0.5 mm
- Nominal outer diameter: 45.0 mm
- Approximate weight: 5988 kg/km
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.268 Ohm/km
- Permissible current rating in open air: 390 A
- Permissible current rating when buried: 386 A
EXG 3*150+95SM
Nexans ref. EXG 005175 - Country ref. EXG 3*150+95SM
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 1.4 mm
- Earth conductor cross section: 95 mm²
- Insulation thickness of smaller conductor: 1.1 mm
- Nominal outer sheath thickness: 2.4 mm
- Tape thickness: 0.5 mm
- Nominal outer diameter: 46.0 mm
- Approximate weight: 6247 kg/km
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.193 Ohm/km
- Permissible current rating in open air: 390 A
- Permissible current rating when buried: 386 A
EXG 3*185+95SM
Nexans ref. EXG 005185 - Country ref. EXG 3*185+95SM
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 185 mm²
- Nominal insulation thickness: 1.6 mm
- Earth conductor cross section: 95 mm²
- Insulation thickness of smaller conductor: 1.1 mm
- Nominal outer sheath thickness: 2.6 mm
- Tape thickness: 0.5 mm
- Nominal outer diameter: 50.0 mm
- Approximate weight: 7434 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.193 Ohm/km
- Permissible current rating in open air: 444 A
- Permissible current rating when buried: 435 A
EXG 3*240+120SM
Nexans ref. EXG 005195 - Country ref. EXG 3*240+120SM
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 1.7 mm
- Earth conductor cross section: 120 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal outer sheath thickness: 2.8 mm
- Tape thickness: 0.5 mm
- Nominal outer diameter: 55.0 mm
- Approximate weight: 9446 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.153 Ohm/km
- Permissible current rating in open air: 522 A
- Permissible current rating when buried: 504 A
EXG 3*300+150SM
Nexans ref. EXG 005205 - Country ref. EXG 3*300+150SM
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 300 mm²
- Nominal insulation thickness: 1.8 mm
- Earth conductor cross section: 150 mm²
- Insulation thickness of smaller conductor: 1.4 mm
- Nominal outer sheath thickness: 2.9 mm
- Tape thickness: 0.5 mm
- Nominal outer diameter: 61.0 mm
- Approximate weight: 11685 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.124 Ohm/km
- Permissible current rating in open air: 595 A
- Permissible current rating when buried: 571 A
EXG 3*35+16 NEW
Nexans ref. EXG 000632 - Country ref. EXG 3*35+16
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Earth conductor cross section: 16 mm²
- Insulation thickness of smaller conductor: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Tape thickness: 0.2 mm
- Nominal outer diameter: 26.0 mm
- Approximate weight: 1576 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Resistance of neutral conductor at 20ºC: 1.15 Ohm/km
- Permissible current rating in open air: 157 A
- Permissible current rating when buried: 170 A
EXG 3*50+25
Nexans ref. EXG 000700 - Country ref. EXG 3*50+25
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Earth conductor cross section: 25 mm²
- Insulation thickness of smaller conductor: 0.9 mm
- Nominal outer sheath thickness: 1.8 mm
- Tape thickness: 0.5 mm
- Nominal outer diameter: 29.0 mm
- Approximate weight: 2196 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.727 Ohm/km
- Permissible current rating in open air: 190 A
- Permissible current rating when buried: 204 A
EXG 3*50+35
Nexans ref. EXG 006136 - Country ref. EXG 3*50+35
- Conductor shape: Circular
- Number of conductors: 4
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Earth conductor cross section: 35 mm²
- Insulation thickness of smaller conductor: 0.9 mm
- Nominal outer sheath thickness: 1.9 mm
- Tape thickness: 0.5 mm
- Nominal outer diameter: 30.0 mm
- Approximate weight: 2196 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.524 Ohm/km
- Permissible current rating in open air: 190 A
- Permissible current rating when buried: 204 A
EXG 3*70+35SM/RM
Nexans ref. EXG 006521 - Country ref. EXG 3*70+35SM//RM
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 1.1 mm
- Earth conductor cross section: 35 mm²
- Insulation thickness of smaller conductor: 0.9 mm
- Nominal outer sheath thickness: 2.0 mm
- Tape thickness: 0.2 mm
- Nominal outer diameter: 32.0 mm
- Approximate weight: 2804 kg/km
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.524 Ohm/km
- Permissible current rating in open air: 242 A
- Permissible current rating when buried: 252 A
EXG 3*95+50SM/RM
Nexans ref. EXG 006522 - Country ref. EXG 3*95+50SM//RM
- Conductor shape: Shaped
- Number of conductors: 4
- Conductor cross-section: 95 mm²
- Nominal insulation thickness: 1.1 mm
- Earth conductor cross section: 50 mm²
- Insulation thickness of smaller conductor: 1.0 mm
- Nominal outer sheath thickness: 2.1 mm
- Tape thickness: 0.5 mm
- Nominal outer diameter: 37.0 mm
- Approximate weight: 4025 kg/km
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.387 Ohm/km
- Permissible current rating in open air: 293 A
- Permissible current rating when buried: 302 A
EXG 4*16+10
Nexans ref. EXG....006143 - Country ref. EXG 4*16+10
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.7 mm
- Earth conductor cross section: 10 mm²
- Insulation thickness of smaller conductor: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Tape thickness: 0.2 mm
- Nominal outer diameter: 22.0 mm
- Approximate weight: 1104 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Resistance of neutral conductor at 20ºC: 1.83 Ohm/km
- Permissible current rating in open air: 96 A
- Permissible current rating when buried: 111 A
EXG 4*25+16
Nexans ref. EXG....006141 - Country ref. EXG 4*25+16
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 25 mm²
- Nominal insulation thickness: 0.9 mm
- Earth conductor cross section: 16 mm²
- Insulation thickness of smaller conductor: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Tape thickness: 0.2 mm
- Nominal outer diameter: 26.0 mm
- Approximate weight: 1584 kg/km
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Resistance of neutral conductor at 20ºC: 1.15 Ohm/km
- Permissible current rating in open air: 127 A
- Permissible current rating when buried: 141 A
EXG 4*35+16
Nexans ref. EXG....006142 - Country ref. EXG 4*35+16
- Conductor shape: Circular
- Number of conductors: 5
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Earth conductor cross section: 16 mm²
- Insulation thickness of smaller conductor: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Tape thickness: 0.2 mm
- Nominal outer diameter: 28.0 mm
- Approximate weight: 1970 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Resistance of neutral conductor at 20ºC: 1.15 Ohm/km
- Permissible current rating in open air: 157 A
- Permissible current rating when buried: 170 A
Description
Description
Standards
-
InternationalIEC 60228; IEC 60332-1-2; IEC 60502-1
1. SCOPE
This specification covers XLPE insulated, circular or shaped, multicore armoured cables, rated at 0.6/1 KV according to IEC 60502-1 for use indoors, outdoors, in cable ducts and for direct burial underground, where severe mechanical stresses are present.
2. CONSTRUCTION
2.1 Phase Conductor
Plain, annealed electrolytic copper conductors, circular stranded, or sectoral stranded only for 3 Cores+Eath: sizes ≥70 to ≤300, conforming to the applicable requirements of IEC 60228.
2.2 Phase Conductor Insulation
XLPE thermosetting material, conforming to the applicable requirements of IEC 60502-1.
2.3 Neutral Conductor
Plain, annealed electrolytic copper conductors, circular stranded, or sectoral stranded only for 3 Cores+Eath: sizes ≥70 to ≤300, conforming to the applicable requirements of IEC 60228.
2.4 Neutral Conductor Insulation
XLPE thermosetting material, conforming to the applicable requirements of IEC 60502-1.
2.5 Assembly
Insulated conductors are laid up, filled where necessary with non-hygroscopic material and covered with an extruded thickness of thermoplastic material.
2.6 Armour
Galvanized Steel Tape Armor complying to the applicable requirements of IEC 60502-1.
2.7 Sheath
PVC based thermoplastic material, conforming to the applicable requirements of IEC 60502-1.
2.8 TESTS
Conforming to the applicable requirements of IEC 60502-1 either on Raw materials or on finished products.
TEST AT WORKS according to IEC 60502-1 armored
Routine Tests
- Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag. 15.1 & 15.2
- Voltage test acc. to IEC 60502-1 parag. 15.1 & 15.3
Liban Cables will carry out these tests on all the lengths and tests certificates will be provided.
Sample Tests
- Check of the build - up and color coding of the cable
- Check of dimensions
Insulation: according to IEC 60502-1 Parag. 16.5.2
Armour: according to IEC 60502-1 Parag. 16.7
Oversheath: according to IEC 60502-1 Parag. 16.5.3
These tests will be carried out on one length of each size during each inspection .
Tests certificates will be provided by Liban Cables
Type Tests
Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-1.
These tests will be carried out on one length of the order .
Tests certificates will be provided by Liban Cables
Cable identification - LV cables ≤ 1KV
INSULATION COLORS:
|
Neutral |
Cond.1 |
Cond.2 |
Cond.3 |
Cond.4 |
1 Conductor |
|
BLACK |
|
|
|
2 Conductors |
GREY |
BLACK |
|
|
|
3 Conductors |
|
BLACK |
RED |
BLUE |
|
4 Conductors |
GREY |
BLACK |
RED |
BLUE |
|
5 Conductors |
GREY |
BLACK |
RED |
BLUE |
GREEN |
All numbered control cables (6 conductors and above), are insulated with white color, and numbered with black digits
CABLE MARKING OVER THE OUTER JACKET (by inkjet printing):
LIBAN CABLES DESCRIPTION RATED VOLTAGE SECTION MM2 Year of manufacture meter marking
Other cable identification requirements are available upon request
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania