Multicore SWA Armored, XLPE insulated, PVC sheathed UV resistant
Multicore SWA Armored, XLPE insulated, PVC sheathed UV resistant
0.6 / 1 KV POWER CABLES Conforming to IEC 60502-1
Read moreEXR 12*1.5 NEW
Nexans ref. EXR 005938 - Country ref. EXR 12*1.5//UV
- Conductor shape: Circular
- Conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 15.0 mm
- Approximate weight: 419 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
EXR 2*16 NEW
Nexans ref. EXR 010502 - Country ref. EXR 2*16//UV
- Conductor shape: Circular
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 20.0 mm
- Approximate weight: 882 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 107 A
- Permissible current rating when buried: 128 A
EXR 2*35 NEW
Nexans ref. EXR 010503 - Country ref. EXR 2*35//UV
- Conductor shape: Circular
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 26.0 mm
- Approximate weight: 1614 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 175 A
- Permissible current rating when buried: 195 A
EXR 2*4 NEW
Nexans ref. EXR 002187 - Country ref. EXR 2*4//UV
- Conductor shape: Circular
- Conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 14.0 mm
- Approximate weight: 382 kg/km
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 45 A
- Permissible current rating when buried: 59 A
EXR 2*50 NEW
Nexans ref. EXR 010513 - Country ref. EXR 2*50//UV
- Conductor shape: Circular
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 29.0 mm
- Approximate weight: 2023 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 212 A
- Permissible current rating when buried: 235 A
EXR 2*6 NEW
Nexans ref. EXR 010501 - Country ref. EXR 2*6//UV
- Conductor shape: Circular
- Conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 15.5 mm
- Approximate weight: 456 kg/km
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 58 A
- Permissible current rating when buried: 74 A
EXR 2*70 NEW
Nexans ref. EXR 010504 - Country ref. EXR 2*70//UV
- Conductor shape: Circular
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 33.0 mm
- Approximate weight: 2645 kg/km
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 270 A
- Permissible current rating when buried: 290 A
EXR 2*95 NEW
Nexans ref. EXR 010505 - Country ref. EXR 2*95//UV
- Conductor shape: Circular
- Conductor cross-section: 95 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer sheath thickness: 2.1 mm
- Nominal outer diameter: 37.0 mm
- Approximate weight: 3624 kg/km
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating in open air: 327 A
- Permissible current rating when buried: 347 A
EXR 3*10 NEW
Nexans ref. EXR 010507 - Country ref. EXR 3*10//UV
- Conductor shape: Circular
- Conductor cross-section: 10 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 19.0 mm
- Approximate weight: 805 kg/km
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 71 A
- Permissible current rating when buried: 88 A
EXR 3*120SM NEW
Nexans ref. EXR 010511 - Country ref. EXR 3*120SM//UV
- Conductor shape: Shaped
- Conductor cross-section: 120 mm²
- Nominal insulation thickness: 1.2 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer sheath thickness: 2.3 mm
- Nominal outer diameter: 40.0 mm
- Approximate weight: 4964 kg/km
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating in open air: 339 A
- Permissible current rating when buried: 345 A
EXR 3*16 NEW
Nexans ref. EXR 005939 - Country ref. EXR 3*16//UV
- Conductor shape: Circular
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 21.0 mm
- Approximate weight: 1036 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 96 A
- Permissible current rating when buried: 111 A
EXR 3*2.5 NEW
Nexans ref. EXR 002188 - Country ref. EXR 3*2.5//UV
- Conductor shape: Circular
- Conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 14.0 mm
- Approximate weight: 355 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 30 A
- Permissible current rating when buried: 40 A
EXR 3*25 NEW
Nexans ref. EXR 010508 - Country ref. EXR 3*25//UV
- Conductor shape: Circular
- Conductor cross-section: 25 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 25.0 mm
- Approximate weight: 1578 kg/km
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 127 A
- Permissible current rating when buried: 141 A
EXR 3*35 NEW
Nexans ref.
- Conductor shape: Circular
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 27.0 mm
- Approximate weight: 1846 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 157 A
- Permissible current rating when buried: 170 A
EXR 3*4 NEW
Nexans ref. EXR 010506 - Country ref. EXR 3*4//UV
- Conductor shape: Circular
- Conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 15.0 mm
- Approximate weight: 432 kg/km
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 40 A
- Permissible current rating when buried: 51 A
EXR 3*50 NEW
Nexans ref. EXR 010510 - Country ref. EXR 3*50//UV
- Conductor shape: Circular
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 30.0 mm
- Approximate weight: 2357 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 190 A
- Permissible current rating when buried: 204 A
EXR 3*6 NEW
Nexans ref. EXR 005930 - Country ref. EXR 3*6//UV
- Conductor shape: Circular
- Conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 16.0 mm
- Approximate weight: 524 kg/km
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 52 A
- Permissible current rating when buried: 64 A
EXR 4*1.5 NEW
Nexans ref. EXR 005931 - Country ref. EXR 4*1.5//UV
- Conductor shape: Circular
- Conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 13.5 mm
- Approximate weight: 335 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 22 A
- Permissible current rating when buried: 29 A
EXR 4*10 NEW
Nexans ref. EXR 002192 - Country ref. EXR 4*10//UV
- Conductor shape: Circular
- Conductor cross-section: 10 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 20.0 mm
- Approximate weight: 946 kg/km
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 71 A
- Permissible current rating when buried: 88 A
EXR 4*120SM NEW
Nexans ref. EXR 001692 - Country ref. EXR 4*120SM//UV
- Conductor shape: Shaped
- Conductor cross-section: 120 mm²
- Nominal insulation thickness: 1.2 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 2.5 mm
- Nominal outer diameter: 47.0 mm
- Approximate weight: 6795 kg/km
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating in open air: 339 A
- Permissible current rating when buried: 345 A
EXR 4*150SM NEW
Nexans ref. EXR 005933 - Country ref. EXR 4*150SM//UV
- Conductor shape: Shaped
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 1.4 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 2.6 mm
- Nominal outer diameter: 51.0 mm
- Approximate weight: 8085 kg/km
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating in open air: 390 A
- Permissible current rating when buried: 386 A
EXR 4*16 NEW
Nexans ref. EXR 002193 - Country ref. EXR 4*16//UV
- Conductor shape: Circular
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 23.0 mm
- Approximate weight: 1346 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 96 A
- Permissible current rating when buried: 111 A
EXR 4*185SM
Nexans ref. EXR 003921 - Country ref. EXR 4*185SM
- Conductor shape: Shaped
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 1.4 mm
- Nominal armour wire diameter: 2.5 mm
- Nominal outer sheath thickness: 2.6 mm
- Nominal outer diameter: 51.0 mm
- Approximate weight: 8085 kg/km
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating in open air: 390 A
- Permissible current rating when buried: 386 A
EXR 4*2.5 NEW
Nexans ref. EXR 002189 - Country ref. EXR 4*2.5//UV
- Conductor shape: Circular
- Conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 15.0 mm
- Approximate weight: 404 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 30 A
- Permissible current rating when buried: 40 A
EXR 4*25 NEW
Nexans ref. EXR 005932 - Country ref. EXR 4*25//UV
- Conductor shape: Circular
- Conductor cross-section: 25 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 27.0 mm
- Approximate weight: 1880 kg/km
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 127 A
- Permissible current rating when buried: 141 A
EXR 4*35 NEW
Nexans ref.
- Conductor shape: Circular
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 29.0 mm
- Approximate weight: 2274 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 157 A
- Permissible current rating when buried: 170 A
EXR 4*4 NEW
Nexans ref. EXR 002190 - Country ref. EXR 4*4//UV
- Conductor shape: Circular
- Conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 16.0 mm
- Approximate weight: 498 kg/km
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 40 A
- Permissible current rating when buried: 51 A
EXR 4*50 NEW
Nexans ref. EXR 010512 - Country ref. EXR 4*50//UV
- Conductor shape: Circular
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 33.0 mm
- Approximate weight: 2921 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 190 A
- Permissible current rating when buried: 204 A
EXR 4*6 NEW
Nexans ref. EXR 002191 - Country ref. EXR 4*6//UV
- Conductor shape: Circular
- Conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 18.0 mm
- Approximate weight: 721 kg/km
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 52 A
- Permissible current rating when buried: 64 A
EXR 4*70SM NEW
Nexans ref. EXR 002181 - Country ref. EXR 4*70SM//UV
- Conductor shape: Shaped
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 37.0 mm
- Approximate weight: 4021 kg/km
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 242 A
- Permissible current rating when buried: 252 A
EXR 4*95SM NEW
Nexans ref. EXR 002194 - Country ref. EXR 4*95SM//UV
- Conductor shape: Shaped
- Conductor cross-section: 95 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal armour wire diameter: 2 mm
- Nominal outer sheath thickness: 2.3 mm
- Nominal outer diameter: 41.0 mm
- Approximate weight: 5159 kg/km
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating in open air: 293 A
- Permissible current rating when buried: 302 A
EXR 5*25 NEW
Nexans ref. EXR 005935 - Country ref. EXR 5*25//UV
- Conductor shape: Circular
- Conductor cross-section: 25 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 29.0 mm
- Approximate weight: 2130 kg/km
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 127 A
- Permissible current rating when buried: 141 A
EXR 5*35 NEW
Nexans ref. EXR 005936 - Country ref. EXR 5*35//UV
- Conductor shape: Circular
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal armour wire diameter: 1.6 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 32.0 mm
- Approximate weight: 2681 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 157 A
- Permissible current rating when buried: 170 A
EXR 5*4 NEW
Nexans ref. EXR 005934 - Country ref. EXR 5*4//UV
- Conductor shape: Circular
- Conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 18.0 mm
- Approximate weight: 672 kg/km
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 40 A
- Permissible current rating when buried: 51 A
EXR 5*6 NEW
Nexans ref. EXR 005928 - Country ref. EXR 5*6//UV
- Conductor shape: Circular
- Conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 1.25 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 19.0 mm
- Approximate weight: 819 kg/km
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 52 A
- Permissible current rating when buried: 64 A
EXR 7*1.5 NEW
Nexans ref. EXR 005937 - Country ref. EXR 7*1.5//UV
- Conductor shape: Circular
- Conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal armour wire diameter: 0.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 15.0 mm
- Approximate weight: 419 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 24 A
- Permissible current rating when buried: 34 A
Description
Description
Standards
-
InternationalIEC 60228; IEC 60332-1-2; IEC 60502-1
1. SCOPE
This specification covers XLPE insulated, circular or shaped, multicore armoured cables, rated at 0.6/1 KV according to IEC 60502-1 for use indoors, outdoors, in cable ducts and for direct burial underground, where severe mechanical stresses are present.
2. CONSTRUCTION
2.1 Conductor
Plain, annealed electrolytic copper conductors, circular stranded, or sectoral stranded, conforming to the applicable requirements of IEC 60228.
2.2 Insulation
XLPE thermosetting material, conforming to the applicable requirements of IEC 60502-1.
2.3 Assembly
Insulated conductors are laid up, filled where necessary with non-hygroscopic material and covered with an extruded thickness of thermoplastic material.
2.4 Armour
Galvanized round wires completely covering the assembly of cores complying to the applicable requirements of IEC 60502-1.
2.5 Sheath
PVC based thermoplastic material, conforming to the applicable requirements of IEC 60502-1.
2.6 TESTS
Conforming to the applicable requirements of IEC 60502-1 either on Raw materials or on finished products.
TEST AT WORKS according to IEC 60502-1 armored
Routine Tests
- Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag. 15.1 & 15.2
- Voltage test acc. to IEC 60502-1 parag. 15.1 & 15.3
Liban Cables will carry out these tests on all the lengths and tests certificates will be provided.
Sample Tests
- Check of the build - up and color coding of the cable
- Check of dimensions
Insulation: according to IEC 60502-1 Parag. 16.5.2
Armour: according to IEC 60502-1 Parag. 16.7
Oversheath: according to IEC 60502-1 Parag. 16.5.3
These tests will be carried out on one length of each size during each inspection .
Tests certificates will be provided by Liban Cables
Type Tests
Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-1.
These tests will be carried out on one length of the order .
Tests certificates will be provided by Liban Cables
Drawing Circular Conductor
Drawing Shaped Conductors
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania