Unarmored, single core PVC insulation, PVC sheathed

Products

E(NYY) 1*1.5

Nexans ref. E(NYY) 000505 - Country ref. E(NYY) 1*1.5

  • Conductor cross-section: 1.5 mm²
  • Conductor diameter: 1.5 mm
  • Nominal insulation thickness: 0.8 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal outer diameter: 5.5 mm
  • Maximum outer diameter: 5.9 mm
  • Approximate weight: 47 kg/km
  • Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
  • Permissible current rating in open air: 20 A
  • Permissible current rating when buried: 26 A
  • Max. conductor temperature in service: 70 °C

 

E(NYY) 1*10

Nexans ref. E(NYY) 000530 - Country ref. E(NYY) 1*10

  • Conductor cross-section: 10 mm²
  • Conductor diameter: 3.8 mm
  • Nominal insulation thickness: 1.0 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal outer diameter: 8.0 mm
  • Maximum outer diameter: 8.56 mm
  • Approximate weight: 151 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 63 A
  • Permissible current rating when buried: 82 A
  • Max. conductor temperature in service: 70 °C

 

E(NYY) 1*120

Nexans ref. E(NYY) 000565 - Country ref. E(NYY) 1*120

  • Conductor cross-section: 120 mm²
  • Conductor diameter: 12.9 mm
  • Nominal insulation thickness: 1.6 mm
  • Nominal outer sheath thickness: 1.5 mm
  • Nominal outer diameter: 19.0 mm
  • Maximum outer diameter: 20.33 mm
  • Approximate weight: 1252 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating in open air: 299 A
  • Permissible current rating when buried: 327 A
  • Max. conductor temperature in service: 70 °C

 

E(NYY) 1*150

Nexans ref. E(NYY) 000570 - Country ref. E(NYY) 1*150

  • Conductor cross-section: 150 mm²
  • Conductor diameter: 14.2 mm
  • Nominal insulation thickness: 1.8 mm
  • Nominal outer sheath thickness: 1.6 mm
  • Nominal outer diameter: 21.0 mm
  • Maximum outer diameter: 22.47 mm
  • Approximate weight: 1530 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating in open air: 344 A
  • Permissible current rating when buried: 365 A
  • Max. conductor temperature in service: 70 °C

 

E(NYY) 1*16

Nexans ref. E(NYY) 000535 - Country ref. E(NYY) 1*16

  • Conductor cross-section: 16 mm²
  • Conductor diameter: 4.7 mm
  • Nominal insulation thickness: 1.0 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal outer diameter: 9.0 mm
  • Maximum outer diameter: 9.63 mm
  • Approximate weight: 209 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 85 A
  • Permissible current rating when buried: 105 A
  • Max. conductor temperature in service: 70 °C

 

E(NYY) 1*185

Nexans ref. E(NYY) 000575 - Country ref. E(NYY) 1*185

  • Conductor cross-section: 185 mm²
  • Conductor diameter: 15.9 mm
  • Nominal insulation thickness: 2.0 mm
  • Nominal outer sheath thickness: 1.7 mm
  • Nominal outer diameter: 23.0 mm
  • Maximum outer diameter: 24.61 mm
  • Approximate weight: 1906 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
  • Permissible current rating in open air: 392 A
  • Permissible current rating when buried: 412 A
  • Max. conductor temperature in service: 70 °C

 

E(NYY) 1*185//MAT-1

Nexans ref. E(NYY) 000721 - Country ref. E(NYY) 1*185//MAT-1

  • Conductor cross-section: 185 mm²
  • Conductor diameter: 15.9 mm
  • Nominal insulation thickness: 2.0 mm
  • Nominal outer sheath thickness: 1.7 mm
  • Nominal outer diameter: 23.0 mm
  • Maximum outer diameter: 24.61 mm
  • Approximate weight: 1906 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
  • Permissible current rating in open air: 392 A
  • Permissible current rating when buried: 412 A
  • Max. conductor temperature in service: 70 °C

 

E(NYY) 1*2.5

Nexans ref. E(NYY) 000515 - Country ref. E(NYY) 1*2.5

  • Conductor cross-section: 2.5 mm²
  • Conductor diameter: 1.9 mm
  • Nominal insulation thickness: 0.8 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal outer diameter: 6.0 mm
  • Maximum outer diameter: 6.42 mm
  • Approximate weight: 60 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 26 A
  • Permissible current rating when buried: 41 A
  • Max. conductor temperature in service: 70 °C

 

E(NYY) 1*240

Nexans ref. E(NYY) 000580 - Country ref. E(NYY) 1*240

  • Conductor cross-section: 240 mm²
  • Conductor diameter: 18.1 mm
  • Nominal insulation thickness: 2.2 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 26.0 mm
  • Maximum outer diameter: 27.82 mm
  • Approximate weight: 2449 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
  • Permissible current rating in open air: 461 A
  • Permissible current rating when buried: 477 A
  • Max. conductor temperature in service: 70 °C

 

E(NYY) 1*25

Nexans ref. E(NYY) 000540 - Country ref. E(NYY) 1*25

  • Conductor cross-section: 25 mm²
  • Conductor diameter: 5.9 mm
  • Nominal insulation thickness: 1.2 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal outer diameter: 11.0 mm
  • Maximum outer diameter: 11.77 mm
  • Approximate weight: 310 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 112 A
  • Permissible current rating when buried: 133 A
  • Max. conductor temperature in service: 70 °C

 

E(NYY) 1*300

Nexans ref. E(NYY) 000585 - Country ref. E(NYY) 1*300

  • Conductor cross-section: 300 mm²
  • Conductor diameter: 20.3 mm
  • Nominal insulation thickness: 2.4 mm
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 28.3 mm
  • Maximum outer diameter: 29.0 mm
  • Approximate weight: 3064 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
  • Permissible current rating in open air: 525 A
  • Permissible current rating when buried: 540 A
  • Max. conductor temperature in service: 70 °C

 

E(NYY) 1*35

Nexans ref. E(NYY) 000545 - Country ref. E(NYY) 1*35

  • Conductor cross-section: 35 mm²
  • Conductor diameter: 6.9 mm
  • Nominal insulation thickness: 1.2 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal outer diameter: 12.0 mm
  • Maximum outer diameter: 12.84 mm
  • Approximate weight: 404 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 138 A
  • Permissible current rating when buried: 161 A
  • Max. conductor temperature in service: 70 °C

 

E(NYY) 1*4

Nexans ref. E(NYY) 000523 - Country ref. E(NYY) 1*4

  • Conductor cross-section: 4 mm²
  • Conductor diameter: 2.4 mm
  • Nominal insulation thickness: 1.0 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal outer diameter: 7.0 mm
  • Maximum outer diameter: 7.49 mm
  • Approximate weight: 84 kg/km
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 35 A
  • Permissible current rating when buried: 49 A
  • Max. conductor temperature in service: 70 °C

 

E(NYY) 1*400

Nexans ref. E(NYY) 000590 - Country ref. E(NYY) 1*400

  • Conductor cross-section: 400 mm²
  • Conductor diameter: 23.2 mm
  • Nominal insulation thickness: 2.6 mm
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 32.0 mm
  • Maximum outer diameter: 34.24 mm
  • Approximate weight: 3887 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
  • Permissible current rating in open air: 613 A
  • Permissible current rating when buried: 622 A
  • Max. conductor temperature in service: 70 °C

 

E(NYY) 1*400//105

Nexans ref. E(NYY) 001590 - Country ref. E(NYY) 1*400//105

  • Conductor cross-section: 400 mm²
  • Conductor diameter: 23.2 mm
  • Nominal insulation thickness: 2.6 mm
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 32.0 mm
  • Maximum outer diameter: 34.24 mm
  • Approximate weight: 3832 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
  • Permissible current rating in open air: 779 A
  • Permissible current rating when buried: 690 A
  • Max. conductor temperature in service: 105 °C

 

E(NYY) 1*50

Nexans ref. E(NYY) 000550 - Country ref. E(NYY) 1*50

  • Conductor cross-section: 50 mm²
  • Conductor diameter: 8.1 mm
  • Nominal insulation thickness: 1.4 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal outer diameter: 13.5 mm
  • Maximum outer diameter: 14.45 mm
  • Approximate weight: 542 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 168 A
  • Permissible current rating when buried: 193 A
  • Max. conductor temperature in service: 70 °C

 

E(NYY) 1*500

Nexans ref. E(NYY) 000593 - Country ref. E(NYY) 1*500

  • Conductor cross-section: 500 mm²
  • Conductor diameter: 26.2 mm
  • Nominal insulation thickness: 2.8 mm
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 36.0 mm
  • Maximum outer diameter: 38.52 mm
  • Approximate weight: 4981 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0366 Ohm/km
  • Permissible current rating in open air: 687 A
  • Permissible current rating when buried: 703 A
  • Max. conductor temperature in service: 70 °C

 

E(NYY) 1*6

Nexans ref. E(NYY) 000525 - Country ref. E(NYY) 1*6

  • Conductor cross-section: 6 mm²
  • Conductor diameter: 3.0 mm
  • Nominal insulation thickness: 1.0 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal outer diameter: 7.5 mm
  • Maximum outer diameter: 8.03 mm
  • Approximate weight: 107 kg/km
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 46 A
  • Permissible current rating when buried: 61 A
  • Max. conductor temperature in service: 70 °C

 

E(NYY) 1*630

Nexans ref. E(NYY) 000595 - Country ref. E(NYY) 1*630

  • Conductor cross-section: 630 mm²
  • Conductor diameter: 30.2 mm
  • Nominal insulation thickness: 2.8 mm
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 40.0 mm
  • Maximum outer diameter: 42.8 mm
  • Approximate weight: 6342 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0283 Ohm/km
  • Permissible current rating in open air: 782 A
  • Permissible current rating when buried: 795 A
  • Max. conductor temperature in service: 70 °C

 

E(NYY) 1*70

Nexans ref. E(NYY) 000555 - Country ref. E(NYY) 1*70

  • Conductor cross-section: 70 mm²
  • Conductor diameter: 9.7 mm
  • Nominal insulation thickness: 1.4 mm
  • Nominal outer sheath thickness: 1.4 mm
  • Nominal outer diameter: 15.0 mm
  • Maximum outer diameter: 16.05 mm
  • Approximate weight: 740 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 213 A
  • Permissible current rating when buried: 238 A
  • Max. conductor temperature in service: 70 °C

 

E(NYY) 1*95

Nexans ref. E(NYY) 000560 - Country ref. E(NYY) 1*95

  • Conductor cross-section: 95 mm²
  • Conductor diameter: 11.4 mm
  • Nominal insulation thickness: 1.6 mm
  • Nominal outer sheath thickness: 1.5 mm
  • Nominal outer diameter: 17.0 mm
  • Maximum outer diameter: 18.19 mm
  • Approximate weight: 1013 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 258 A
  • Permissible current rating when buried: 286 A
  • Max. conductor temperature in service: 70 °C

 

Description

Description

Standards

  • Product
    IEC 60228; IEC 60502-1
  • Test
    IEC 60332-1-2

Scope

This specification covers PVC insulated, circular, single core unarmoured cables, rated at 0.6/1 KV according to IEC 60502-1 for use indoors, outdoors, and in cable ducts.

Construction

2.1 Conductor

Plain, annealed electrolytic copper conductors, circular stranded, conforming to the applicable requirements of IEC 60228.

2.2 Insulation

PVC material, conforming to the applicable requirements of IEC 60502-1.

2.3 Sheath

PVC based thermoplastic material, conforming to the applicable requirements of IEC 60502-1.

2.4 TESTS

Conforming to the applicable requirements of IEC 60502-1 either on Raw materials or on finished products.

TEST AT WORKS unarmored single core

Routine Tests

 -  Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag. 15.1 & 15.2

 -  Spark test during insulation                                                       

 Liban Cables will carry out these tests on all the length and tests certificates will be provided.                                                                  

                                                                       

Sample Tests                                                              

 -          Check of the build - up and color coding of the cable                                                      

 -          Check of dimensions                                                    

            Insulation          :           according to IEC 60502-1                       Parag.  16.5.2

            Oversheath       :           according to IEC 60502-1                       Parag.  16.5.3

                                                                       

These tests will be carried out on one length during  of each size during each inspection . 

Tests certificates will be provided by Liban Cables 

                                                                       

Type Tests                                                                  

Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-1.

These tests will be carried out on one length of the order.

Tests certificates will be provided by Liban Cables

Cable identification - LV cables ≤ 1KV

INSULATION COLORS:   

 

Neutral

Cond.1

Cond.2

 Cond.3

Cond.4

1 Conductor

 

BLACK

 

 

 

2 Conductors

GREY

BLACK

 

 

 

3 Conductors

 

BLACK

RED

BLUE

 

4 Conductors

GREY

BLACK

RED

BLUE

 

5 Conductors

GREY

BLACK

RED

BLUE

GREEN

 

All numbered control cables (6 conductors and above), are insulated with white color, and numbered with black digits

 

CABLE MARKING OVER THE OUTER JACKET  (by inkjet printing):

LIBAN CABLES     DESCRIPTION     RATED VOLTAGE     SECTION MM2     Year of manufacture     meter marking

 

Other cable identification requirements are available upon request

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Class 2 IEC 60228
Conductor material
Copper
Conductor shape
Circular
Number of conductors
1
Insulation
PVC
Outer sheath
PVC

Electrical characteristics

Electrical characteristics

Thermal soil resistivity wet zone
1 °K.m/W
Rated Voltage Uo/U (Um)
0,6/1 kV

Mechanical characteristics

Mechanical characteristics

Cable flexibility
6xD

Usage characteristics

Usage characteristics

Operating temperature, range
-15 ... 55 °C
Installation temperature, range
-5 ... 50 °C
Ambient air temperature
30 °C
Short-circuit max. conductor temperature
160 °C
Flame retardant
IEC 60332-1-2
Laying depth, center of system
600 mm

Resources

Resources

Find a Distributor

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close