Unarmored, single core XLPE insulation, PVC sheathed
EX 1*1.5
Nexans ref. EX 000122 - Country ref. EX 1*1.5
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.7 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 5.3 mm
- Approximate weight: 42 kg/km
- Maximum outer diameter: 5.67 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 19 A
- Permissible current rating when buried: 29 A
EX 1*10
Nexans ref. EX 000160 - Country ref. EX 1*10
- Conductor cross-section: 10 mm²
- Conductor diameter: 3.8 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 8.0 mm
- Approximate weight: 133 kg/km
- Maximum outer diameter: 8.56 mm
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 80 A
- Permissible current rating when buried: 91 A
EX 1*120
Nexans ref. EX 000230 - Country ref. EX 1*120
- Conductor cross-section: 120 mm²
- Conductor diameter: 12.9 mm
- Nominal insulation thickness: 1.2 mm
- Nominal outer sheath thickness: 1.5 mm
- Nominal outer diameter: 18.0 mm
- Approximate weight: 1185 kg/km
- Maximum outer diameter: 19.26 mm
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating in open air: 379 A
- Permissible current rating when buried: 363 A
EX 1*150
Nexans ref. EX 000240 - Country ref. EX 1*150
- Conductor cross-section: 150 mm²
- Conductor diameter: 14.2 mm
- Nominal insulation thickness: 1.4 mm
- Nominal outer sheath thickness: 1.6 mm
- Nominal outer diameter: 20.0 mm
- Approximate weight: 1452 kg/km
- Maximum outer diameter: 21.4 mm
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating in open air: 435 A
- Permissible current rating when buried: 405 A
EX 1*16
Nexans ref. EX 000170 - Country ref. EX 1*16
- Conductor cross-section: 16 mm²
- Conductor diameter: 4.7 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 8.5 mm
- Approximate weight: 190 kg/km
- Maximum outer diameter: 9.1 mm
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 107 A
- Permissible current rating when buried: 118 A
EX 1*185
Nexans ref. EX 000250 - Country ref. EX 1*185
- Conductor cross-section: 185 mm²
- Conductor diameter: 15.9 mm
- Nominal insulation thickness: 1.6 mm
- Nominal outer sheath thickness: 1.6 mm
- Nominal outer diameter: 22.0 mm
- Approximate weight: 1801 kg/km
- Maximum outer diameter: 23.54 mm
- Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
- Permissible current rating in open air: 496 A
- Permissible current rating when buried: 457 A
EX 1*2.5
Nexans ref. EX 000130 - Country ref. EX 1*2.5
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 1.9 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 6.0 mm
- Approximate weight: 54 kg/km
- Maximum outer diameter: 6.42 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 46 A
EX 1*240
Nexans ref. EX 000260 - Country ref. EX 1*240
- Conductor cross-section: 240 mm²
- Conductor diameter: 18.1 mm
- Nominal insulation thickness: 1.7 mm
- Nominal outer sheath thickness: 1.7 mm
- Nominal outer diameter: 25.0 mm
- Approximate weight: 2315 kg/km
- Maximum outer diameter: 26.75 mm
- Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
- Permissible current rating in open air: 584 A
- Permissible current rating when buried: 529 A
EX 1*25
Nexans ref. EX 000180 - Country ref. EX 1*25
- Conductor cross-section: 25 mm²
- Conductor diameter: 5.9 mm
- Nominal insulation thickness: 0.9 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 10.0 mm
- Approximate weight: 285 kg/km
- Maximum outer diameter: 10.7 mm
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 142 A
- Permissible current rating when buried: 148 A
EX 1*300
Nexans ref. EX 000270 - Country ref. EX 1*300
- Conductor cross-section: 300 mm²
- Conductor diameter: 20.3 mm
- Nominal insulation thickness: 1.8 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 27.0 mm
- Approximate weight: 2897 kg/km
- Maximum outer diameter: 28.89 mm
- Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
- Permissible current rating in open air: 665 A
- Permissible current rating when buried: 600 A
EX 1*35
Nexans ref. EX 000190 - Country ref. EX 1*35
- Conductor cross-section: 35 mm²
- Conductor diameter: 6.9 mm
- Nominal insulation thickness: 0.9 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 11.0 mm
- Approximate weight: 374 kg/km
- Maximum outer diameter: 11.77 mm
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 175 A
- Permissible current rating when buried: 179 A
EX 1*4
Nexans ref. EX 000145 - Country ref. EX 1*4
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.4 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 6.0 mm
- Approximate weight: 71 kg/km
- Maximum outer diameter: 6.42 mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 45 A
- Permissible current rating when buried: 59 A
EX 1*400
Nexans ref. EX 000280 - Country ref. EX 1*400
- Conductor cross-section: 400 mm²
- Conductor diameter: 23.2 mm
- Nominal insulation thickness: 2.0 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 31.0 mm
- Approximate weight: 3704 kg/km
- Maximum outer diameter: 33.17 mm
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
- Permissible current rating in open air: 779 A
- Permissible current rating when buried: 690 A
EX 1*50
Nexans ref. EX 000200 - Country ref. EX 1*50
- Conductor cross-section: 50 mm²
- Conductor diameter: 8.1 mm
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 13.0 mm
- Approximate weight: 500 kg/km
- Maximum outer diameter: 13.91 mm
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 212 A
- Permissible current rating when buried: 214 A
EX 1*500
Nexans ref. EX 000290 - Country ref. EX 1*500
- Conductor cross-section: 500 mm²
- Conductor diameter: 26.2 mm
- Nominal insulation thickness: 2.2 mm
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 34.0 mm
- Approximate weight: 4714 kg/km
- Maximum outer diameter: 36.38 mm
- Max. DC resistance of the conductor at 20°C: 0.0366 Ohm/km
- Permissible current rating in open air: 870 A
- Permissible current rating when buried: 780 A
EX 1*6
Nexans ref. EX 000010 - Country ref. EX 1*6//RED
- Conductor cross-section: 6 mm²
- Conductor diameter: 3.0 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 7.0 mm
- Approximate weight: 92 kg/km
- Maximum outer diameter: 7.49 mm
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 58 A
- Permissible current rating when buried: 68 A
EX 1*6
Nexans ref. EX 000150 - Country ref. EX 1*6
- Conductor cross-section: 6 mm²
- Conductor diameter: 3.0 mm
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 7.0 mm
- Approximate weight: 92 kg/km
- Maximum outer diameter: 7.49 mm
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 58 A
- Permissible current rating when buried: 68 A
EX 1*630
Nexans ref. EX 000300 - Country ref. EX 1*630
- Conductor cross-section: 630 mm²
- Conductor diameter: 30.2 mm
- Nominal insulation thickness: 2.4 mm
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 39.0 mm
- Approximate weight: 6122 kg/km
- Maximum outer diameter: 41.73 mm
- Max. DC resistance of the conductor at 20°C: 0.0283 Ohm/km
- Permissible current rating in open air: 995 A
- Permissible current rating when buried: 880 A
EX 1*70
Nexans ref. EX 000210 - Country ref. EX 1*70
- Conductor cross-section: 70 mm²
- Conductor diameter: 9.7 mm
- Nominal insulation thickness: 1.1 mm
- Nominal outer sheath thickness: 1.4 mm
- Nominal outer diameter: 14.5 mm
- Approximate weight: 697 kg/km
- Maximum outer diameter: 15.52 mm
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 270 A
- Permissible current rating when buried: 264 A
EX 1*800
Nexans ref. EX 000703 - Country ref. EX 1*800
- Conductor cross-section: 630 mm²
- Conductor diameter: 30.2 mm
- Nominal insulation thickness: 2.4 mm
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 39.0 mm
- Approximate weight: 6122 kg/km
- Maximum outer diameter: 41.73 mm
- Max. DC resistance of the conductor at 20°C: 0.0283 Ohm/km
- Permissible current rating in open air: 995 A
- Permissible current rating when buried: 880 A
EX 1*95
Nexans ref. EX 000220 - Country ref. EX 1*95
- Conductor cross-section: 95 mm²
- Conductor diameter: 11.4 mm
- Nominal insulation thickness: 1.1 mm
- Nominal outer sheath thickness: 1.5 mm
- Nominal outer diameter: 16.0 mm
- Approximate weight: 947 kg/km
- Maximum outer diameter: 17.12 mm
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating in open air: 327 A
- Permissible current rating when buried: 317 A
Description
Description
Standards
-
ProductIEC 60228; IEC 60502-1
-
TestIEC 60332-1-2
0.6 / 1 KV POWER CABLES
Conforming to IEC 60502-1
TEST AT WORKS unarmored single core
Routine Tests
- Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag. 15.1 & 15.2
- Spark test during insulation
Liban Cables will carry out these tests on all the length and tests certificates will be provided.
Sample Tests
- Check of the build - up and color coding of the cable
- Check of dimensions
Insulation : according to IEC 60502-1 Parag. 16.5.2
Oversheath : according to IEC 60502-1 Parag. 16.5.3
These tests will be carried out on one length during of each size during each inspection .
Tests certificates will be provided by Liban Cables
Type Tests
Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-1.
These tests will be carried out on one length of the order.
Tests certificates will be provided by Liban Cables
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Find a Distributor
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania