0.6/1kv POWER CABLES conforming to IEC 60502-1 & IEC 60331
Read moreSFC2XU 2*1.5
Nexans ref. SFC2XU 000280 - Country ref. SFC2XU 2*1.5//CEI-1
- Number of conductors: 2
- Number of cores: 2
- Conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 10.5 mm
- Approximate weight: 154 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
SFC2XU 2*2.5
Nexans ref. SFC2XU 000226 - Country ref. SFC2XU 2*2.5//CEI-1
- Number of conductors: 2
- Number of cores: 2
- Conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 11.5 mm
- Approximate weight: 192 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
SFC2XU 2*4
Nexans ref. SFC2XU 000241 - Country ref. SFC2XU 2*4//CEI-1
- Number of conductors: 2
- Number of cores: 2
- Conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 13.0 mm
- Approximate weight: 253 kg/km
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
SFC2XU 3*1.5
Nexans ref. SFC2XU 000293 - Country ref. SFC2XU 3*1.5//CEI-1
- Number of conductors: 3
- Number of cores: 3
- Conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 11.5 mm
- Approximate weight: 172 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
SFC2XU 3*10
Nexans ref. SFC2XU 001356 - Country ref. SFC2XU 3*10//CEI-1
- Number of conductors: 3
- Number of cores: 3
- Conductor cross-section: 10 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 16.0 mm
- Approximate weight: 512 kg/km
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
SFC2XU 3*16
Nexans ref. SFC2XU.001358 - Country ref. SFC2XU 3*16//CEI-1
- Number of conductors: 3
- Number of cores: 3
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 18.0 mm
- Approximate weight: 719 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
SFC2XU 3*2.5
Nexans ref. SFC2XU 001350 - Country ref. SFC2XU 3*2.5//CEI-1
- Number of conductors: 3
- Number of cores: 3
- Conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 12.5 mm
- Approximate weight: 216 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
SFC2XU 3*240
Nexans ref. SFC2XU.000300 - Country ref. SFC2XU 3*240//CEI-1
- Number of conductors: 3
- Number of cores: 3
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 1.7 mm
- Nominal outer sheath thickness: 2.6 mm
- Nominal overall diameter: 53.0 mm
- Approximate weight: 8469 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
SFC2XU 3*4
Nexans ref. SFC2XU 001352 - Country ref. SFC2XU 3*4//CEI-1
- Number of conductors: 3
- Number of cores: 3
- Conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 13.5 mm
- Approximate weight: 280 kg/km
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
SFC2XU 3*6
Nexans ref. SFC2XU.001354 - Country ref. SFC2XU 3*6//CEI-1
- Number of conductors: 3
- Number of cores: 3
- Conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 14.5 mm
- Approximate weight: 364 kg/km
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
SFC2XU 4*1.5
Nexans ref. SFC2XU 000281 - Country ref. SFC2XU 4*1.5//CEI-1
- Number of conductors: 4
- Number of cores: 4
- Conductor cross-section: 1.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 12.0 mm
- Approximate weight: 200 kg/km
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
SFC2XU 4*10
Nexans ref. SFC2XU 000285 - Country ref. SFC2XU 4*10//CEI-1
- Number of conductors: 4
- Number of cores: 4
- Conductor cross-section: 10 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 17.5 mm
- Approximate weight: 607 kg/km
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
SFC2XU 4*120 NEW
Nexans ref. SFC2XU 002017 - Country ref. SFC2XU 4*120//CEI-1
- Number of conductors: 4
- Number of cores: 4
- Conductor cross-section: 120 mm²
- Nominal insulation thickness: 1.2 mm
- Nominal outer sheath thickness: 2.3 mm
- Nominal overall diameter: 43.0 mm
- Approximate weight: 5495 kg/km
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
SFC2XU 4*150 NEW
Nexans ref. SFC2XU 002019 - Country ref. SFC2XU 4*150//CEI-1
- Number of conductors: 4
- Number of cores: 4
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 1.4 mm
- Nominal outer sheath thickness: 2.4 mm
- Nominal overall diameter: 47.0 mm
- Approximate weight: 6746 kg/km
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
SFC2XU 4*16
Nexans ref. SFC2XU 000367 - Country ref. SFC2XU 4*16//CEI-1
- Number of conductors: 4
- Number of cores: 4
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 19.5 mm
- Approximate weight: 871 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
SFC2XU 4*185 NEW
Nexans ref. SFC2XU 002020 - Country ref. SFC2XU 4*185//CEI-1
- Number of conductors: 4
- Number of cores: 4
- Conductor cross-section: 185 mm²
- Nominal insulation thickness: 1.6 mm
- Nominal outer sheath thickness: 2.6 mm
- Nominal overall diameter: 53.0 mm
- Approximate weight: 8356 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
SFC2XU 4*2.5 NEW
Nexans ref. SFC2XU 000282 - Country ref. SFC2XU 4*2.5//CEI-1
- Number of conductors: 4
- Number of cores: 4
- Conductor cross-section: 2.5 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 13.5 mm
- Approximate weight: 256 kg/km
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
SFC2XU 4*240 NEW
Nexans ref. SFC2XU 001689 - Country ref. SFC2XU 4*240//CEI-1
- Number of conductors: 4
- Number of cores: 4
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 1.7 mm
- Nominal outer sheath thickness: 2.8 mm
- Nominal overall diameter: 59.0 mm
- Approximate weight: 10794 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
SFC2XU 4*25
Nexans ref. SFC2XU 000432 - Country ref. SFC2XU 4*25//CEI-1
- Number of conductors: 4
- Number of cores: 4
- Conductor cross-section: 25 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 0.9 mm
- Nominal overall diameter: 24.0 mm
- Approximate weight: 1308 kg/km
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
SFC2XU 4*35
Nexans ref. SFC2XU 000378 - Country ref. SFC2XU 4*35//CEI-1
- Number of conductors: 4
- Number of cores: 4
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 26.0 mm
- Approximate weight: 1732 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
SFC2XU 4*4
Nexans ref. SFC2XU 000283 - Country ref. SFC2XU 4*4//CEI-1
- Number of conductors: 4
- Number of cores: 4
- Conductor cross-section: 4 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 14.5 mm
- Approximate weight: 335 kg/km
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
SFC2XU 4*50 NEW
Nexans ref. SFC2XU 000444 - Country ref. SFC2XU 4*50//CEI-1
- Number of conductors: 4
- Number of cores: 4
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 1.9 mm
- Nominal overall diameter: 30.0 mm
- Approximate weight: 2325 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
SFC2XU 4*6
Nexans ref. SFC2XU 000284 - Country ref. SFC2XU 4*6//CEI-1
- Number of conductors: 4
- Number of cores: 4
- Conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 15.5 mm
- Approximate weight: 424 kg/km
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
SFC2XU 4*70 NEW
Nexans ref. SFC2XU 000446 - Country ref. SFC2XU 4*70//CEI-1
- Number of conductors: 4
- Number of cores: 4
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal outer sheath thickness: 2.0 mm
- Nominal overall diameter: 35.0 mm
- Approximate weight: 3245 kg/km
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
SFC2XU 4*95 NEW
Nexans ref. SFC2XU 002018 - Country ref. SFC2XU 4*95//CEI-1
- Number of conductors: 4
- Number of cores: 4
- Conductor cross-section: 95 mm²
- Nominal insulation thickness: 1.1 mm
- Nominal outer sheath thickness: 2.1 mm
- Nominal overall diameter: 39.0 mm
- Approximate weight: 4359 kg/km
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
SFC2XU 5*10
Nexans ref. SFC2XU 000290 - Country ref. SFC2XU 5*10//CEI-1
- Number of conductors: 5
- Number of cores: 5
- Conductor cross-section: 10 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 19.0 mm
- Approximate weight: 742 kg/km
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
SFC2XU 5*16
Nexans ref. SFC2XU 000291 - Country ref. SFC2XU 5*16//CEI-1
- Number of conductors: 5
- Number of cores: 5
- Conductor cross-section: 16 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 22.0 mm
- Approximate weight: 1068 kg/km
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
SFC2XU 5*400 NEW
Nexans ref. SFC2XU 002701 - Country ref. SFC2XU 5*400//CEI-1
- Number of conductors: 5
- Number of cores: 5
- Conductor cross-section: 400 mm²
- Nominal insulation thickness: 2.0 mm
- Nominal outer sheath thickness: 3.6 mm
- Nominal overall diameter: 82.0 mm
- Approximate weight: 21361 kg/km
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
SFC2XU 5*50
Nexans ref. SFC2XU 000292 - Country ref. SFC2XU 5*50//CEI-1
- Number of conductors: 5
- Number of cores: 5
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Nominal outer sheath thickness: 2.0 mm
- Nominal overall diameter: 33.0 mm
- Approximate weight: 2902 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
SFC2XU 5*6
Nexans ref. SFC2XU 000289 - Country ref. SFC2XU 5*6//CEI-1
- Number of conductors: 5
- Number of cores: 5
- Conductor cross-section: 6 mm²
- Nominal insulation thickness: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 17.0 mm
- Approximate weight: 513 kg/km
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
Description
Description
Standards
-
ProductIEC 60502-1
-
TestIEC 60331
CONSTRUCTION
1- Conductors
stranded-class 2 according to IEC 60228
2 - Mica tape
MICA/GLASS FIRE RESISTANT TAPE
3 - Insulation
XLPE
4 - Outer sheath
Halogen free compound, Color as per customer requirement
5 - Packing
Drums can be wooden or steel
Test at works for fire resistant cables
Routine Tests
- Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag. 15.1 & 15.2
- Voltage test acc. to IEC 60502-1 parag.15.1& 15.3
Liban Cables will carry out these tests on all the lengths and tests certificates will be provided.
Sample Tests
- Check of the build - up and color coding of the cable
- Check of dimensions
Insulation : according to IEC 60502-1 Parag. 16.5.2
Oversheath : according to IEC 60502-1 Parag. 16.5.3
These tests will be carried out on one length of each size during each inspection .
Tests certificates will be provided by Liban Cables
Type Tests
Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-1.
Fire resistance test according to IEC 60331-21 ( 750°C for 90 mins. ) :
- 500V between conductors
These tests will be carried out on one length of the order. Tests certificates will be provided by Liban Cables
Cable identification - LV cables ≤ 1KV
INSULATION COLORS:
|
Neutral |
Cond.1 |
Cond.2 |
Cond.3 |
Cond.4 |
1 Conductor |
|
BLACK |
|
|
|
2 Conductors |
GREY |
BLACK |
|
|
|
3 Conductors |
|
BLACK |
RED |
BLUE |
|
4 Conductors |
GREY |
BLACK |
RED |
BLUE |
|
5 Conductors |
GREY |
BLACK |
RED |
BLUE |
GREEN |
All numbered control cables (6 conductors and above), are insulated with white color, and numbered with black digits
CABLE MARKING OVER THE OUTER JACKET (by inkjet printing):
LIBAN CABLES DESCRIPTION RATED VOLTAGE SECTION MM2 Year of manufacture meter marking
Other cable identification requirements are available upon request
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Find a Distributor
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania