Unarmored , Halogen free, Low smoke, Fire & UV resistant Multicore (PN) cables
Unarmored , Halogen free, Low smoke, Fire & UV resistant Multicore (PN) cables
0.6/1kv POWER CABLES conforming to IEC 60502-1 & IEC 60331
Read moreSFC2XU 3*120+70
Nexans ref. SFC2XU.001700 - Country ref. SFC2XU 3*120+70//CEI-UV
- Packaging: Cut to length (m)
- Number of conductors: 4
- Outer sheath: LFH (Low Fire hazard) compound
- Conductor cross-section: 120 mm²
- Nominal insulation thickness: 1.2 mm
- Earth conductor cross section: 70 mm²
- Insulation thickness of smaller conductor: 1.1 mm
- Nominal outer sheath thickness: 2.2 mm
- Nominal overall diameter: 41.0 mm
- Approximate weight: 5248 kg/km
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.268 Ohm/km
SFC2XU 3*35+16
Nexans ref. SFC2XU.001796 - Country ref. SFC2XU 3*35+16//CEI-UV
- Number of conductors: 4
- Outer sheath: LSZH compound
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Earth conductor cross section: 16 mm²
- Insulation thickness of smaller conductor: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 25.0 mm
- Approximate weight: 1548 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Resistance of neutral conductor at 20ºC: 1.15 Ohm/km
SFC2XU 3*50+25
Nexans ref. SFC2XU.001043 - Country ref. SFC2XU 3*50+25//CEI-UV
- Number of conductors: 4
- Outer sheath: LFH (Low Fire hazard) compound
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Earth conductor cross section: 25 mm²
- Insulation thickness of smaller conductor: 0.9 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 29.0 mm
- Approximate weight: 2133 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.727 Ohm/km
SFC2XU 4*120+70
Nexans ref. SFC2XU.001821 - Country ref. SFC2XU 4*120+70//CEI-UV
- Packaging: Cut to length (m)
- Number of conductors: 5
- Outer sheath: LFH (Low Fire hazard) compound
- Conductor cross-section: 120 mm²
- Nominal insulation thickness: 1.2 mm
- Earth conductor cross section: 70 mm²
- Insulation thickness of smaller conductor: 1.1 mm
- Nominal outer sheath thickness: 2.4 mm
- Nominal overall diameter: 46.0 mm
- Approximate weight: 6237 kg/km
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.268 Ohm/km
SFC2XU 4*150+70 NEW
Nexans ref. SFC2XU.001818 - Country ref. SFC2XU 4*150+70//CEI-UV
- Packaging: Cut to length (m)
- Number of conductors: 5
- Outer sheath: LFH (Low Fire hazard) compound
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 1.4 mm
- Earth conductor cross section: 70 mm²
- Insulation thickness of smaller conductor: 1.1 mm
- Nominal outer sheath thickness: 2.5 mm
- Nominal overall diameter: 50.0 mm
- Approximate weight: 7471 kg/km
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.268 Ohm/km
SFC2XU 4*150+95 NEW
Nexans ref. SFC2XU.001820 - Country ref. SFC2XU 4*150+95//CEI-UV
- Packaging: Cut to length (m)
- Number of conductors: 5
- Outer sheath: LFH (Low Fire hazard) compound
- Conductor cross-section: 150 mm²
- Nominal insulation thickness: 1.4 mm
- Earth conductor cross section: 95 mm²
- Insulation thickness of smaller conductor: 1.1 mm
- Nominal outer sheath thickness: 2.5 mm
- Nominal overall diameter: 51.0 mm
- Approximate weight: 7752 kg/km
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.193 Ohm/km
SFC2XU 4*185+95 NEW
Nexans ref. SFC2XU.001817 - Country ref. SFC2XU 4*185+95//CEI-UV
- Packaging: Cut to length (m)
- Number of conductors: 5
- Outer sheath: LFH (Low Fire hazard) compound
- Conductor cross-section: 185 mm²
- Nominal insulation thickness: 1.6 mm
- Earth conductor cross section: 95 mm²
- Insulation thickness of smaller conductor: 1.1 mm
- Nominal outer sheath thickness: 2.7 mm
- Nominal overall diameter: 56.0 mm
- Approximate weight: 9339 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.193 Ohm/km
SFC2XU 4*240+120
Nexans ref. SFC2XU.004344 - Country ref. SFC2XU 4*240+120//CEI-UV
- Number of conductors: 5
- Outer sheath: LFH (Low Fire hazard) compound
- Conductor cross-section: 240 mm²
- Nominal insulation thickness: 1.7 mm
- Earth conductor cross section: 120 mm²
- Insulation thickness of smaller conductor: 1.2 mm
- Nominal outer sheath thickness: 2.9 mm
- Nominal overall diameter: 62.0 mm
- Approximate weight: 12020 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.153 Ohm/km
SFC2XU 4*25+16 NEW
Nexans ref. SFC2XU.001810 - Country ref. SFC2XU 4*25+16//CEI-UV
- Packaging: Cut to length (m)
- Number of conductors: 5
- Outer sheath: LFH (Low Fire hazard) compound
- Conductor cross-section: 25 mm²
- Nominal insulation thickness: 0.9 mm
- Earth conductor cross section: 16 mm²
- Insulation thickness of smaller conductor: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 25.0 mm
- Approximate weight: 1504 kg/km
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Resistance of neutral conductor at 20ºC: 1.15 Ohm/km
SFC2XU 4*300+150
Nexans ref. SFC2XU 001819 - Country ref. SFC2XU 4*300+150//CEI-UV
- Number of conductors: 5
- Outer sheath: LFH (Low Fire hazard) compound
- Conductor cross-section: 300 mm²
- Nominal insulation thickness: 1.8 mm
- Earth conductor cross section: 150 mm²
- Insulation thickness of smaller conductor: 1.4 mm
- Nominal outer sheath thickness: 3.1 mm
- Nominal overall diameter: 69.0 mm
- Approximate weight: 15103 kg/km
- Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.124 Ohm/km
SFC2XU 4*35+16
Nexans ref. SFC2XU.000813 - Country ref. SFC2XU 4*35+16//CEI-UV
- Number of conductors: 5
- Outer sheath: LFH (Low Fire hazard) compound
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Earth conductor cross section: 16 mm²
- Insulation thickness of smaller conductor: 0.7 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 27.0 mm
- Approximate weight: 1910 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Resistance of neutral conductor at 20ºC: 1.15 Ohm/km
SFC2XU 4*35+25
Nexans ref. SFC2XU 000815 - Country ref. SFC2XU 4*35+25//CEI-UV
- Number of conductors: 5
- Outer sheath: LFH (Low Fire hazard) compound
- Conductor cross-section: 35 mm²
- Nominal insulation thickness: 0.9 mm
- Earth conductor cross section: 25 mm²
- Insulation thickness of smaller conductor: 0.9 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 28.0 mm
- Approximate weight: 2047 kg/km
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Resistance of neutral conductor at 20ºC: 1.15 Ohm/km
SFC2XU 4*50+25
Nexans ref. SFC2XU 001814 - Country ref. SFC2XU 4*50+25//CEI-UV
- Number of conductors: 5
- Outer sheath: LFH (Low Fire hazard) compound
- Conductor cross-section: 50 mm²
- Nominal insulation thickness: 1.0 mm
- Earth conductor cross section: 25 mm²
- Insulation thickness of smaller conductor: 0.9 mm
- Nominal outer sheath thickness: 1.8 mm
- Nominal overall diameter: 33.0 mm
- Approximate weight: 3144 kg/km
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.727 Ohm/km
SFC2XU 4*70+35 NEW
Nexans ref. SFC2XU.001816 - Country ref. SFC2XU 4*70+35//CEI-UV
- Packaging: Cut to length (m)
- Number of conductors: 5
- Outer sheath: LFH (Low Fire hazard) compound
- Conductor cross-section: 70 mm²
- Nominal insulation thickness: 1.1 mm
- Earth conductor cross section: 35 mm²
- Insulation thickness of smaller conductor: 0.9 mm
- Nominal outer sheath thickness: 2.1 mm
- Nominal overall diameter: 37.0 mm
- Approximate weight: 3633 kg/km
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.524 Ohm/km
SFC2XU 4*95+50 NEW
Nexans ref. SFC2XU 000822 - Country ref. SFC2XU 4*95+50//CEI-UV
- Packaging: Cut to length (m)
- Number of conductors: 5
- Outer sheath: LFH (Low Fire hazard) compound
- Conductor cross-section: 95 mm²
- Nominal insulation thickness: 1.1 mm
- Earth conductor cross section: 50 mm²
- Insulation thickness of smaller conductor: 1.0 mm
- Nominal outer sheath thickness: 2.2 mm
- Nominal overall diameter: 41.0 mm
- Approximate weight: 4882 kg/km
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Resistance of neutral conductor at 20ºC: 0.387 Ohm/km
Description
Description
Standards
-
ProductIEC 60502-1
-
TestIEC 60331-1 or 2
CONSTRUCTION
1- Phase Conductor
stranded-class 2 according to IEC 60228
2 - Phase conductor Insulation
MICA/GLASS FIRE RESISTANT TAPE + XLPE
3- Neutral Conductor
stranded-class 2 according to IEC 60228
4 - Neutral conductor Insulation
MICA/GLASS FIRE RESISTANT TAPE + XLPE
5 - Assembly
Insulated conductors are laid up, filled where necessary with non-hygroscopic material.
6 - Outer sheath
Low Fire Hazard compound, Color as per customer requirement
7 - Packing
Drums can be wooden or steel
TEST AT WORKS FOR FIRE RESISTANT MULTICORE CABLES
Routine Tests
- Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag. 15.1 & 15.2
- Voltage test acc. to IEC 60502-1 parag.15.1& 15.3
Liban Cables will carry out these tests on all the lengths and tests certificates will be provided.
Sample Tests
- Check of the build - up and color coding of the cable
- Check of dimensions
Insulation : according to IEC 60502-1 Parag. 16.5.2
Oversheath : according to IEC 60502-1 Parag. 16.5.3
These tests will be carried out on one length of each size during each inspection .
Tests certificates will be provided by Liban Cables
Type Tests
Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break ) in accordance with IEC 60502-1.
Fire resistance test according to IEC 60331-21 ( 750°C for 90 mins. ) :
- 500V between conductors
These tests will be carried out on one length of the order .
Tests certificates will be provided by Liban Cables
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Find a Distributor
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania