YnHKXS 6/10KV up to 18/30 KV IEC 60332-3
YnHKXS 6/10KV up to 18/30 KV IEC 60332-3
XLPE Unarmored cable with Copper conductor
international code: N2XSY
YnHKXS 1*120/50 6/10KV
Nexans ref. M3N4 000646 - Country ref. M3N4 1*120/50//POL-2
- Conductor cross-section: 120 mm²
- Conductor diameter: 12.9 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 30.0 mm
- Approximate net weight: 2081 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
YnHKXS 1*150/50 6/10KV
Nexans ref. M3N4 009521 - Country ref. M3N4 1*150/50//POL-2
- Conductor cross-section: 150 mm²
- Conductor diameter: 14.2 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 32.0 mm
- Approximate net weight: 2385 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
YnHKXS 1*185/50 6/10KV
Nexans ref. M3N4 000162 - Country ref. M3N4 1*185/50//POL-2
- Conductor cross-section: 185 mm²
- Conductor diameter: 15.9 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 33.0 mm
- Approximate net weight: 2735 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
YnHKXS 1*240/50 6/10KV
Nexans ref. M3N4 000647 - Country ref. M3N4 1*240/50//POL-2
- Conductor cross-section: 240 mm²
- Conductor diameter: 18.1 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.5 mm
- Nominal outer diameter: 35.0 mm
- Approximate net weight: 3218 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
YnHKXS 1*240/50 8.7/15KV
Nexans ref. M4N4 001730 - Country ref. M4N4 1*240/50//POL-2
- Conductor cross-section: 240 mm²
- Conductor diameter: 18.1 mm
- Nominal insulation thickness: 4.5 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.1 mm
- Nominal outer diameter: 38.0 mm
- Approximate net weight: 3444 kg/km
- Test voltage: 30 kV
- Rated Voltage Uo/U (Um): 8.7 / 15 (18) kV
YnHKXS 1*300/50 6/10KV
Nexans ref. M3N4 020374 - Country ref. M3N4 1*300/50//POL-2
- Conductor cross-section: 300 mm²
- Conductor diameter: 20.3 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 3.2 mm
- Nominal outer diameter: 38.0 mm
- Approximate net weight: 3944 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
YnHKXS 1*400/50 6/10KV
Nexans ref. M3N4 001162 - Country ref. M3N4 1*400/50//POL-2
- Conductor cross-section: 400 mm²
- Conductor diameter: 23.2 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 42.0 mm
- Approximate net weight: 4832 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
YnHKXS 1*400/95 6/10KV
Nexans ref. M3N4 001164 - Country ref. M3N4 1*400/95//POL-2
- Conductor cross-section: 400 mm²
- Conductor diameter: 23.2 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 95 mm²
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 43.0 mm
- Approximate net weight: 5270 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
YnHKXS 1*70/35 6/10KV
Nexans ref. M3N4 001730 - Country ref. M3N4 1*70/35//POL-2
- Conductor cross-section: 70 mm²
- Conductor diameter: 9.7 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 35 mm²
- Nominal outer sheath thickness: 1.7 mm
- Nominal outer diameter: 26.0 mm
- Approximate net weight: 1399 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
YnHKXS 1*70/50 6/10KV
Nexans ref. M3N4 081729 - Country ref. M3N4 1*70/50//POL-2
- Conductor cross-section: 70 mm²
- Conductor diameter: 9.7 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 1.7 mm
- Nominal outer diameter: 27.0 mm
- Approximate net weight: 1540 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
YnHKXS 1*95/35 8.7/15KV
Nexans ref. M4N4 001731 - Country ref. M4N4 1*95/35//POL-2
- Conductor cross-section: 95 mm²
- Conductor diameter: 11.4 mm
- Nominal insulation thickness: 4.5 mm
- Screen section: 35 mm²
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 31.0 mm
- Approximate net weight: 1798 kg/km
- Test voltage: 30 kV
- Rated Voltage Uo/U (Um): 8.7 / 15 (18) kV
YnHKXS 1*95/50 6/10KV
Nexans ref. M3N4 009645 - Country ref. M3N4 1*95/50//POL-2
- Conductor cross-section: 95 mm²
- Conductor diameter: 11.4 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 1.8 mm
- Nominal outer diameter: 29.0 mm
- Approximate net weight: 1824 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
Description
Description
Standards
-
ProductIEC 60502-2
-
TestIEC 60332-1-2; IEC 60332-3
Power use outdoor application, even wet.
Suitable for fixed installations at open air, in tube or canals and underground.
Max. Operation temperature: 90°
Max. Short circuit temperature : 250° (Max 5 s)
Construction
1. Conductor:
Compacted Round conductor class 2
2. Insulation:
Extruded inner semi conductive layer, XLPE insulation and extruded outer semi conductive layer + Semi-conductive tape
3. Metallic screen layer:
Copper wires with open helix copper tape
4. Outer sheath:
Low Temperature PVC, Red or as per customer requirement
5. Marking:
By Inkjet
6. Packing:
Drums can be wooden or steel
TEST AT WORKS according to IEC 60502-2 & IEC 60332-3
Routine Tests
-Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-2 parag. 16.1 & 16.2
-High voltage test acc. to IEC 60502-2 parag. 16.1 & 16.4
-Max. partial discharge test at 1.73 Uo acc. to IEC 60502-2 parag. 16.1 & 16.3
Liban Cables will carry out these tests on all the lengths and tests certificates will be provided
Sample tests
- Check of the build - up and color coding of the cable
- Check of dimensions
Insulation : according to IEC 60502-2 Parag. 17.5.2
Metallic screen : according to IEC 60502-2 Parag. 17.7
Oversheath : according to IEC 60502-2 Parag. 17.5.3
- Hot Set Test for XLPE insulation according to IEC 60502-2 parag. 17.10
These tests will be carried out on one length of each size during each inspection .
Tests certificates will be provided by Liban Cables
Type tests
Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-2.
Fire retardance test according to IEC 60332-3
These tests will be carried out on one length of the order.
Tests certificates will be provided by Liban Cables
DRAWING YnHKXS
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania