N2XS(FL)2Y 110kV

Products

2XS(FL)2Y 1*300/95 64/110KV NEW

Nexans ref. H9N4DP 001496 - Country ref. H 9N4DP 1*300/95(FL)//POL

  • Packaging: Cut to length (m)
  • Conductor shape: Round compacted
  • Conductor cross-section: 300 mm²
  • Conductor diameter: 20.3 mm
  • Nominal insulation thickness: 15.0 mm
  • Screen section: 95 mm²
  • Nominal outer sheath thickness: 3.2 mm
  • Nominal outer diameter: 69.0 mm
  • Maximum outer diameter: - mm
  • Approximate net weight: 6343 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.078 Ohm/km
  • Laying formation: trefoil
  • Minimum operating temperature: -30 °C

 

2XS(FL)2Y 1*630/95 64/110KV NEW

Nexans ref. H9N4DP 000080 - Country ref. H 9N4DP 1*630/95(FL)//NE-PO

  • Packaging: Cut to length (m)
  • Conductor shape: Round compacted
  • Conductor cross-section: 630 mm²
  • Conductor diameter: 30.2 mm
  • Nominal insulation thickness: 15.0 mm
  • Screen section: 95 mm²
  • Nominal outer sheath thickness: 3.4 mm
  • Nominal outer diameter: 79.0 mm
  • Maximum outer diameter: - mm
  • Approximate net weight: 10022 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0283 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0391 Ohm/km
  • Laying formation: trefoil
  • Minimum operating temperature: -30 °C

 

2XS(FL)2Y 1*800/120 64/110kV NEW

Nexans ref. H9N4DP 001620 - Country ref. H9N4DP 1*800/120(FL)//NEX-POL

  • Packaging: Cut to length (m)
  • Conductor shape: Circular non compacted
  • Conductor cross-section: 800 mm²
  • Conductor diameter: 37.0 mm
  • Nominal insulation thickness: 13.5 mm
  • Screen section: 120 mm²
  • Nominal outer sheath thickness: 3.6 mm
  • Nominal outer diameter: 84.0 mm
  • Maximum outer diameter: 90.0 mm
  • Approximate net weight: 12000 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0221 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0327 Ohm/km
  • Laying formation: trefoil
  • Minimum operating temperature: -35 °C

 

2XS(FL)2Y 1*800/120 64/110kV NEW

Nexans ref. H9N4DP 001700 - Country ref. H9N4DP 1*800/120(FL)//NEX-POL,

  • Packaging: Cut to length (m)
  • Conductor shape: Circular non compacted
  • Conductor cross-section: 800 mm²
  • Conductor diameter: 37.0 mm
  • Nominal insulation thickness: 13.5 mm
  • Screen section: 120 mm²
  • Nominal outer sheath thickness: 3.6 mm
  • Nominal outer diameter: 84.0 mm
  • Maximum outer diameter: - mm
  • Approximate net weight: 12000 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0221 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0327 Ohm/km
  • Laying formation: trefoil
  • Minimum operating temperature: -35 °C

 

2XS(FL)2Y 1*800/95 64/110KV NEW

Nexans ref. H9N4DP 001502 - Country ref. H 9N4DP 1*800/95(FL)//NEX-POL,

  • Packaging: Cut to length (m)
  • Conductor shape: Round compacted
  • Conductor cross-section: 800 mm²
  • Conductor diameter: 34.2 mm
  • Nominal insulation thickness: 15.0 mm
  • Screen section: 95 mm²
  • Nominal outer sheath thickness: 3.6 mm
  • Nominal outer diameter: 84.0 mm
  • Maximum outer diameter: - mm
  • Approximate net weight: 11840 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0221 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0338 Ohm/km
  • Laying formation: trefoil
  • Minimum operating temperature: -30 °C

 

2XS(FL)2Y 1*800/95 64/110kV NEW

Nexans ref. H9N4DP 001500 - Country ref. H 9N4DP 1*800/95(FL)//NEX-POL

  • Packaging: Cut to length (m)
  • Conductor shape: Round compacted
  • Conductor cross-section: 800 mm²
  • Conductor diameter: 35.2 mm
  • Nominal insulation thickness: 15.0 mm
  • Screen section: 95 mm²
  • Nominal outer sheath thickness: 3.6 mm
  • Nominal outer diameter: 85.0 mm
  • Maximum outer diameter: - mm
  • Approximate net weight: 12166 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0221 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0338 Ohm/km
  • Laying formation: trefoil
  • Minimum operating temperature: -30 °C

 

N2XS(FL)2Y 1*630/95 64/110KV

Nexans ref. H9N4DP 700212 - Country ref. H9N4DP 1*630/95(FL)//POL

  • Packaging: Cut to length (m)
  • Conductor shape: Round compacted
  • Conductor cross-section: 630 mm²
  • Conductor diameter: 30.2 mm
  • Nominal insulation thickness: 15.0 mm
  • Screen section: 95 mm²
  • Nominal outer sheath thickness: 3.4 mm
  • Nominal outer diameter: 79.0 mm
  • Maximum outer diameter: - mm
  • Approximate net weight: 9599 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0283 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0395 Ohm/km
  • Laying formation: trójkątny układ
  • Minimum operating temperature: -30 °C

 

N2XS(FL)2Y 1*800/95 64/110kV NEW

Nexans ref. H9N4DP 000235 - Country ref. H 9N4DP 1*800/95(FL)//POL-6

  • Packaging: Cut to length (m)
  • Conductor shape: Circular non compacted
  • Conductor cross-section: 800 mm²
  • Conductor diameter: 37.0 mm
  • Nominal insulation thickness: 15.0 mm
  • Screen section: 95 mm²
  • Nominal outer sheath thickness: 3.6 mm
  • Nominal outer diameter: 86.0 mm
  • Maximum outer diameter: - mm
  • Approximate net weight: 12065 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0221 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.033 Ohm/km
  • Laying formation: trefoil
  • Minimum operating temperature: -35 °C

 

N2XS(FL)2Y 1*800/95 64/110kV NEW

Nexans ref. H9N4DP 000234 - Country ref. H9N4DP 1*800/95(FL)//POL-5

  • Packaging: Cut to length (m)
  • Conductor shape: Circular non compacted
  • Conductor cross-section: 800 mm²
  • Conductor diameter: 37.0 mm
  • Nominal insulation thickness: 15.0 mm
  • Screen section: 95 mm²
  • Nominal outer sheath thickness: 3.6 mm
  • Nominal outer diameter: 86.0 mm
  • Maximum outer diameter: - mm
  • Approximate net weight: 12122 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0221 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.033 Ohm/km
  • Laying formation: trefoil
  • Minimum operating temperature: -35 °C

 

N2XS(FL)2Y 1*800/95 64/110kV NEW

Nexans ref. H9N4DP 000237 - Country ref. H9N4DP 1*800/95(FL)//POL-5,

  • Packaging: Cut to length (m)
  • Conductor shape: Circular non compacted
  • Conductor cross-section: 800 mm²
  • Conductor diameter: 37.0 mm
  • Nominal insulation thickness: 15.0 mm
  • Screen section: 95 mm²
  • Nominal outer sheath thickness: 3.6 mm
  • Nominal outer diameter: 86.0 mm
  • Maximum outer diameter: - mm
  • Approximate net weight: 12122 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0221 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.033 Ohm/km
  • Laying formation: trefoil
  • Minimum operating temperature: -35 °C

 

Description

Description

Standards

  • Test
    IEC 60840

APPLICATION / ZASTOSOWANIE

Application in ground, outdoors, in tubes, indoors and in cable ducts. All high voltage cables are manufactured on the basis of specifications and can be adapted to the requirements of the customer. Therefore, all technical information are purely for information purposes and the electrical characteristics are calculated for values which are specified in the data sheets. For your specific requirements and laying arrangements please don't hesitate to contact us.

Zastosowanie w ziemi, na zewnątrz, w rurach, wewnątrz i w kanałach kablowych. Wszystkie kable wysokiego napięcia są produkowane na podstawie specyfikacji i mogą być dostosowane do wymagań klienta. W związku z tym wszystkie informacje techniczne mają charakter wyłącznie informacyjny, a parametry elektryczne są obliczane na podstawie wartości określonych w kartach katalogowych. W przypadku konkretnych wymagań i układania kabli prosimy o kontakt z nami.

DESCRIPTION / OPIS

CU/S.C/XLPE/S.C/S.C Swell. tape/Cu wires+OPEN HELIX COPPER TAPE/Swell. tape/Alucopo/PE

Stranded copper conductor class 2 according to IEC 60228, semi conducting conductor screen, insulation of cross-linked polyethylene (XLPE), semi conducting insulation screen, semi conducting swellable bedding, copper screen, swellable bedding, aluminium tape bonded to PE sheath.

Żyła miedziana wielodrutowa klasy 2 zgodnie z IEC 60228, ekran półprzewodzący na żyle, izolacja z polietylenu sieciowanego (XLPE), ekran półprzewodzący na izolacji, półprzewodząca warstwa pęczniejąca, żyła powrotna z miedzi, pęczniejąca warstwa, taśma aluminiowa połączona z powłoką PE.

TEST AT WORKS HV CABLES / PRÓBY FABRYCZNE

Routine Tests / Badania rutynowe:

 -          Max. partial discharge test  at 1.5 Uo acc. to IEC 60840  parag.9.2 / Badanie maksymalnych wyładowań niezupełnych przy 1,5 Uo zgodnie z IEC 60840 pkt 9.2

 -          High voltage test acc. to IEC 60840  parag. 9.3 / Próba wysokim napięciem zgodnie z IEC 60840 pkt 9.3

 

Liban Cables will carry out these tests on all the lengths and tests certificates will be provided / Firma Liban Cables przeprowadzi te badania dla wszystkich odcinków kabli i dostarczy świadectwa z badań

 

Sample tests / Badania próbek:

 -          Conductor examination  acc. to IEC 60840 parag. 10.4 / Badanie dyrygenta IEC 60840 pkt 10.4

 -          Max. DC resistance of conductor acc. to IEC 60840 parag. 10.5 / Maks. rezystancja DC żył  i IEC 60840 pkt 10.5

 -          Check of dimensions / Sprawdzenie wymiarów

                        Insulation / Izolacja   :  according to IEC 60840 / zgodnie z IEC 60840          Parag.  10.6.2 / pkt 10.6.2

                        Metallic screen / Ekran metaliczny  :  according to IEC 60840 / zgodnie z IEC 60840    Parag.  10.7  / pkt 10.7

                        Oversheath / Powłoka zewnętrzna : according to IEC 60840 / zgodnie z IEC 60840   Parag.  10.6.3 / pkt 10.6.3

 -          Hot set test for insulation XLPE acc. to IEC 60840 parag. 10.9 /-Badanie stopnia usieciowania izolacji z XLPE zgodnie z IEC 60840 pkt 10.9

 -          Measurement of capacitance acc. to IEC 60840 parag. 10.10 / Pomiar pojemności zgodnie z IEC 60840 pkt 10.10

 

These tests will be carried out on one length of each size during each inspection / Badania te – podczas każdej kontroli – zostaną przeprowadzone na jednym odcinku dla każdego rozmiaru kabla.

Tests certificates will be provided by Liban Cables / Świadectwa z badań dostarczy firma Liban Cables.

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Number of conductors
1
Conductor material
Copper
Conductor flexibility
Stranded class 2
Material of the inner semi-conductor
Semi-conducting compound
Insulation
XLPE
Material of the external semi-conductor
Extruded fully bonded
Material used for longitudinal water tightness
Swellable tape
Concentric conductor
Copper wires and helical copper tape
Protection
Aluminium tape
Outer sheath
PE
Sheath colour
Black

Electrical characteristics

Electrical characteristics

Test voltage
160 kV
Rated Voltage Uo/U (Um)
64 / 110 (123) KV

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Good

Usage characteristics

Usage characteristics

Number of systems
1
Bending factor when laying
30 (xD)
Laying depth, center of system
1300 mm
Ambient air temperature
30 °C
Ambient ground temperature
20 °C
Max. conductor temperature in service
90 °C
Short-circuit max. conductor temperature
250 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close