N2XSR(AL)Y 26/46kV
N2XSR(AL)Y 26/46kV
26/46(52)kV Single core Copper XLPE Cable, Cu wires Screen, armored, PVC sheath
Read moreN2XSR(AL)Y 1*300/95 26/46kV
Nexans ref. H7N4W 000139 - Country ref. H7N4W 1*300/95//ROM
Description
Description
Standards
-
InternationalIEC 60502-2; IEC 60840
CU/S.C/XLPE/S.C/S.C tape/Cu wires+OPEN HELIX COPPER TAPE/PVC/AWA/PVC
APPLICATION
Application outdoors, indoors, in ground, in tubes, and in cable ducts.
All high voltage cables are manufactured on the basis of specifications and can be adapted to the requirements of the customer. Therefore, all technical information are purely for information purposes and the electrical characteristics are calculated for values which are specified in the data sheets. For your specific requirements and laying arrangements please don't hesitate to contact us.
DESCRIPTION
Stranded Copper conductor class 2 according to IEC 60228, semi conducting conductor screen, insulation of cross-linked polyethylene (XLPE), semi conducting insulation screen, semi conducting bedding, copper screen, separation sheath, aluminium wires armoring, low temperature PVC sheath.
TEST AT WORKS for HV armored cables
Routine Tests
- Max. partial discharge test at 1.5 Uo acc. to IEC 60840 parag.9.2
- High voltage test acc. to IEC 60840 parag. 9.3
Liban Cables will carry out these tests on all the lengths and tests certificates will be provided.
Sample Tests
- Conductor examination acc. to IEC 60840 parag. 10.4
- Max. DC resistance of conductor acc. to IEC 60840 parag. 10.5
- Check of thicknesses
Insulation : according to IEC 60840 Parag. 10.6.2
Metallic screen : according to IEC 60840 Parag. 10.7
Separation sheath : according to IEC 60502-2 Parag. 17.5.3
Armouring : according to IEC 60502-2 Parag. 17.7
Oversheath : according to IEC 60840 Parag. 10.6.3
- Hot set test for insulation acc. to IEC 60840 parag. 10.9
- Measurement of capacitance acc. to IEC 60840 parag. 10.10
These tests will be carried out on one length of each size during each inspection .
Tests certificates will be provided by Liban Cables
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics