Single core AL Cond., CWS, unarmored cables

Products

M5A4 1*120/16

Nexans ref. M5A4 001254 - Country ref. M5A4 1*120/16//RED

  • Outer sheath: PVC
  • Colour: Red
  • Conductor diameter: 12.8 mm
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 31.0 mm
  • Approximate net weight: 1086 kg/km
  • Perm current rating in air 30°C: 324 A
  • Permissible current rating when buried: 252 A
  • Max. DC resistance of the conductor at 20°C: 0.323 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.253 Ohm/km
  • Operating temperature, range: -15 ... 55 °C

 

M5A4 1*150/25

Nexans ref. M5A4 001255 - Country ref. M5A4 1*150/25//RED

  • Outer sheath: PVC
  • Colour: Red
  • Conductor diameter: 14.4 mm
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 32.0 mm
  • Approximate net weight: 1891 kg/km
  • Perm current rating in air 30°C: 368 A
  • Permissible current rating when buried: 281 A
  • Max. DC resistance of the conductor at 20°C: 0.264 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.206 Ohm/km
  • Operating temperature, range: -15 ... 55 °C

 

M5A4 1*300/25

Nexans ref. M5A4 001256 - Country ref. M5A4 1*300/25//RED

  • Outer sheath: PVC
  • Colour: Red
  • Conductor diameter: 20.3 mm
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 39.0 mm
  • Approximate net weight: 1891 kg/km
  • Perm current rating in air 30°C: 577 A
  • Permissible current rating when buried: 414 A
  • Max. DC resistance of the conductor at 20°C: 0.129 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.1 Ohm/km
  • Operating temperature, range: -15 ... 55 °C

 

M5A4 1*500/35

Nexans ref. M5A4 001257 - Country ref. M5A4 1*500/35//RED

  • Outer sheath: PVC
  • Colour: Red
  • Conductor diameter: 26.2 mm
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 35 mm²
  • Nominal outer sheath thickness: 2.4 mm
  • Nominal outer diameter: 46.0 mm
  • Approximate net weight: 2758 kg/km
  • Perm current rating in air 30°C: 789 A
  • Permissible current rating when buried: 537 A
  • Max. DC resistance of the conductor at 20°C: 0.0605 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0794 Ohm/km
  • Operating temperature, range: -15 ... 55 °C

 

M5A4 1*95/16

Nexans ref. M5A4 001700 - Country ref. M5A4 1*95/16

  • Outer sheath: PVC
  • Colour: Black
  • Conductor diameter: 11.7 mm
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 30.0 mm
  • Approximate net weight: 984 kg/km
  • Perm current rating in air 30°C: 280 A
  • Permissible current rating when buried: 221 A
  • Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.41 Ohm/km
  • Operating temperature, range: -15 ... 55 °C

 

M5A4P 1*150/25

Nexans ref. M5A4P 000155 - Country ref. M5A4P 1*150/25

  • Outer sheath: PE-HD
  • Colour: Black
  • Conductor diameter: 14.4 mm
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 32.0 mm
  • Approximate net weight: 1194 kg/km
  • Perm current rating in air 30°C: 368 A
  • Permissible current rating when buried: 281 A
  • Max. DC resistance of the conductor at 20°C: 0.264 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.206 Ohm/km
  • Operating temperature, range: -30 ... 55 °C

 

M5A4P 1*300/25

Nexans ref. M5A4P 001267 - Country ref. M5A4P 1*300/25

  • Outer sheath: PE-HD
  • Colour: Black
  • Conductor diameter: 20.3 mm
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 39.0 mm
  • Approximate net weight: 1774 kg/km
  • Perm current rating in air 30°C: 577 A
  • Permissible current rating when buried: 414 A
  • Max. DC resistance of the conductor at 20°C: 0.129 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.1 Ohm/km
  • Operating temperature, range: -30 ... 55 °C

 

M5A4P 1*95/16

Nexans ref. M5A4P 001700 - Country ref. M5A4P 1*95/16

  • Outer sheath: PE
  • Colour: Black
  • Conductor diameter: 11.7 mm
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 30.0 mm
  • Approximate net weight: 905 kg/km
  • Perm current rating in air 30°C: 280 A
  • Permissible current rating when buried: 221 A
  • Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.41 Ohm/km
  • Operating temperature, range: -30 ... 55 °C

 

M6A4 1*500/35

Nexans ref. M6A4 000358 - Country ref. M6A4 1*500/35

  • Outer sheath: PVC
  • Colour: Black
  • Conductor diameter: 26.2 mm
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 35 mm²
  • Nominal outer sheath thickness: 2.6 mm
  • Nominal outer diameter: 51.0 mm
  • Approximate net weight: 3103 kg/km
  • Perm current rating in air 30°C: 789 A
  • Permissible current rating when buried: 537 A
  • Max. DC resistance of the conductor at 20°C: 0.0605 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0794 Ohm/km
  • Operating temperature, range: -15 ... 55 °C

 

M6A5 1*120/16//GAM

Nexans ref. M6A5 001118 - Country ref. M6A5 1*120/16//GAM

  • Outer sheath: PVC
  • Colour: Black
  • Conductor diameter: 12.8 mm
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 35.0 mm
  • Approximate net weight: 1315 kg/km
  • Perm current rating in air 30°C: 324 A
  • Permissible current rating when buried: 252 A
  • Max. DC resistance of the conductor at 20°C: 0.253 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.323 Ohm/km
  • Operating temperature, range: -15 ... 55 °C

 

M6A5 1*120/16//GAM1

Nexans ref. M6A5 002118 - Country ref. M6A5 1*120/16//GAM1

  • Outer sheath: PVC
  • Colour: Black
  • Conductor diameter: 12.8 mm
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 35.0 mm
  • Approximate net weight: 1315 kg/km
  • Perm current rating in air 30°C: 324 A
  • Permissible current rating when buried: 252 A
  • Max. DC resistance of the conductor at 20°C: 0.253 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.323 Ohm/km
  • Operating temperature, range: -15 ... 55 °C

 

M6A5 1*150/16//GAM

Nexans ref. M6A5 001119 - Country ref. M6A5 1*150/16//GAM

  • Outer sheath: PVC
  • Colour: Black
  • Conductor diameter: 14.4 mm
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 37.0 mm
  • Approximate net weight: 1459 kg/km
  • Perm current rating in air 30°C: 368 A
  • Permissible current rating when buried: 281 A
  • Max. DC resistance of the conductor at 20°C: 0.202 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.264 Ohm/km
  • Operating temperature, range: -15 ... 55 °C

 

M6A5 1*150/16//GAM1

Nexans ref. M6A5 002119 - Country ref. M6A5 1*150/16//GAM1

  • Outer sheath: PVC
  • Colour: Black
  • Conductor diameter: 14.4 mm
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 37.0 mm
  • Approximate net weight: 1459 kg/km
  • Perm current rating in air 30°C: 368 A
  • Permissible current rating when buried: 281 A
  • Max. DC resistance of the conductor at 20°C: 0.202 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.264 Ohm/km
  • Operating temperature, range: -15 ... 55 °C

 

M6A5 1*185/16//GAM1

Nexans ref. M6A5 002139 - Country ref. M6A5 1*185/16//GAM1

  • Outer sheath: PVC
  • Colour: Black
  • Conductor diameter: 16.2 mm
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 39.0 mm
  • Approximate net weight: 1635 kg/km
  • Perm current rating in air 30°C: 424 A
  • Permissible current rating when buried: 317 A
  • Max. DC resistance of the conductor at 20°C: 0.164 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.21 Ohm/km
  • Operating temperature, range: -15 ... 55 °C

 

M6A5 1*240/16//GAM

Nexans ref. M6A5 001130 - Country ref. M6A5 1*240/16//GAM

  • Outer sheath: PVC
  • Colour: Black
  • Conductor diameter: 17.9 mm
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 2.3 mm
  • Nominal outer diameter: 48.0 mm
  • Approximate net weight: 1846 kg/km
  • Perm current rating in air 30°C: 502 A
  • Permissible current rating when buried: 367 A
  • Max. DC resistance of the conductor at 20°C: 0.125 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.161 Ohm/km
  • Operating temperature, range: -15 ... 55 °C

 

M6A5 1*240/16//GAM1

Nexans ref. M6A5 002130 - Country ref. M6A5 1*240/16//GAM1

  • Outer sheath: PVC
  • Colour: Black
  • Conductor diameter: 17.9 mm
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 2.3 mm
  • Nominal outer diameter: 48.0 mm
  • Approximate net weight: 1846 kg/km
  • Perm current rating in air 30°C: 502 A
  • Permissible current rating when buried: 367 A
  • Max. DC resistance of the conductor at 20°C: 0.125 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.161 Ohm/km
  • Operating temperature, range: -15 ... 55 °C

 

M6A5 1*300/16//GAM

Nexans ref. M6A5 001121 - Country ref. M6A5 1*300/16//GAM

  • Outer sheath: PVC
  • Colour: Black
  • Conductor diameter: 20.3 mm
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 2.4 mm
  • Nominal outer diameter: 44.0 mm
  • Approximate net weight: 2119 kg/km
  • Perm current rating in air 30°C: 577 A
  • Permissible current rating when buried: 414 A
  • Max. DC resistance of the conductor at 20°C: 0.1 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.129 Ohm/km
  • Operating temperature, range: -15 ... 55 °C

 

M6A5 1*300/16//GAM1

Nexans ref. M6A5 002121 - Country ref. M6A5 1*300/16//GAM1

  • Outer sheath: PVC
  • Colour: Black
  • Conductor diameter: 20.3 mm
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 2.4 mm
  • Nominal outer diameter: 44.0 mm
  • Approximate net weight: 2119 kg/km
  • Perm current rating in air 30°C: 577 A
  • Permissible current rating when buried: 414 A
  • Max. DC resistance of the conductor at 20°C: 0.1 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.129 Ohm/km
  • Operating temperature, range: -15 ... 55 °C

 

M6A5 1*400/16//GAM

Nexans ref. M6A5 001132 - Country ref. M6A5 1*400/16//GAM

  • Outer sheath: PVC
  • Colour: Black
  • Conductor diameter: 23.2 mm
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 2.5 mm
  • Nominal outer diameter: 47.0 mm
  • Approximate net weight: 2519 kg/km
  • Perm current rating in air 30°C: 673 A
  • Permissible current rating when buried: 470 A
  • Max. DC resistance of the conductor at 20°C: 0.0778 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0997 Ohm/km
  • Operating temperature, range: -15 ... 55 °C

 

M6A5 1*400/16//GAM1

Nexans ref. M6A5 002132 - Country ref. M6A5 1*400/16//GAM1

  • Outer sheath: PVC
  • Colour: Black
  • Conductor diameter: 23.2 mm
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 2.5 mm
  • Nominal outer diameter: 47.0 mm
  • Approximate net weight: 2519 kg/km
  • Perm current rating in air 30°C: 673 A
  • Permissible current rating when buried: 470 A
  • Max. DC resistance of the conductor at 20°C: 0.0778 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0997 Ohm/km
  • Operating temperature, range: -15 ... 55 °C

 

M6A5 1*630/16//GAM

Nexans ref. M6A5 001631 - Country ref. M6A5 1*630/16//GAM

  • Outer sheath: PVC
  • Colour: Black
  • Conductor diameter: 29.6 mm
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 2.7 mm
  • Nominal outer diameter: 55.0 mm
  • Approximate net weight: 3509 kg/km
  • Perm current rating in air 30°C: 916 A
  • Permissible current rating when buried: 611 A
  • Max. DC resistance of the conductor at 20°C: 0.0469 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0626 Ohm/km
  • Operating temperature, range: -15 ... 55 °C

 

M6A5 1*630/16//GAM1

Nexans ref. M6A5 002631 - Country ref. M6A5 1*630/16//GAM1

  • Outer sheath: PVC
  • Colour: Black
  • Conductor diameter: 29.6 mm
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 16 mm²
  • Nominal outer sheath thickness: 2.7 mm
  • Nominal outer diameter: 55.0 mm
  • Approximate net weight: 3509 kg/km
  • Perm current rating in air 30°C: 916 A
  • Permissible current rating when buried: 611 A
  • Max. DC resistance of the conductor at 20°C: 0.0469 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0626 Ohm/km
  • Operating temperature, range: -15 ... 55 °C

 

Description

Description

Standards

  • International
    IEC 60228; IEC 60332-1-2; IEC 60502-2

1-SCOPE

This specification covers Single core unarmoured cables, conforming to IEC 60502-2 Specifications.
 

2. CONSTRUCTION

2.1 Conductor

Aluminum conductors, conforming to the applicable requirements of IEC 60228.
2.2 Insulation

Extruded inner semi conductive layer, XLPE insulation and  extruded outer semi conductive layer .

2.3 Metallic Screen Layer

Copper wires and open helix copper tape

2.4 Sheath

PVC .

3. TESTS

All tests required by IEC 60502-2 either on Raw material or on finished products.

TEST AT WORKS ACCORDING TO IEC 60502-2 / PRÓBY FABRYCZNE XNUHAKXS, XNUHKXS

Routine Tests / Badania rutynowe:

• Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-2 parag.16.2 / Maks. rezystancja DC żył w temperaturze 20°C zgodnie z IEC 60228 i IEC 60502-2 pkt 16.2

• High voltage test acc. to IEC 60502-2 parag. 16.4 / Próba wysokim napięciem zgodnie z IEC 60502-2 pkt 16.4

• Max. partial discharge test at 1.73 Uo acc. to IEC 60502-2 parag. 16.3 / Badanie maksymalnych wyładowań niezupełnych przy 1,73 Uo zgodnie z IEC 60502-2 pkt 16.3

 

Liban Cables will carry out these tests on all the lengths and tests certificates will be provided  / Firma Liban Cables przeprowadzi te badania dla wszystkich odcinków kabli i dostarczy świadectwa z badań

 

Sample tests / Badania próbek:

• Check of the build - up and color coding of the cable / Sprawdzenie rozwijania i kolorowych oznaczeń kabla

• Check of dimensions / Sprawdzenie wymiarów

Insulation / Izolacja        :           according to IEC 60502-2 / zgodnie z IEC 60502-2          Parag. / pkt.      17.5.2

Metallic screen / Ekran metaliczny          :           according to IEC 60502-2 / zgodnie z IEC 60502-2          Parag. / pkt.            17.7

Oversheath / Powłoka zewnętrzna           :           according to IEC 60502-2 / zgodnie z IEC 60502-2          Parag. / pkt.            17.5.3

- Hot Set Test for XLPE insulation according to IEC 60502-2 parag. 17.10 /-Badanie stopnia usieciowania izolacji z XLPE zgodnie z IEC 60502-2 pkt 17.10

 

These tests will be carried out on one length of each size during each inspection . / Badania te – podczas każdej kontroli – zostaną przeprowadzone na jednym odcinku dla każdego rozmiaru kabla.

Tests certificates will be provided by Liban Cables / Świadectwa z badań dostarczy firma Liban Cables

 

Type tests / Próby typu

Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break ) in accordance with IEC 60502-2. / Charakterystyki mechaniczne materiałów izolacji i powłoki zewnętrznej (wytrzymałość na rozciąganie i wydłużenie przy zerwaniu) zgodnie z IEC 60502-2.

These tests will be carried out on one length of the order / Badania te zostaną przeprowadzone na jednym odcinku z zamówienia

Tests certificates will be provided by Liban Cables / Świadectwa z badań dostarczy firma Liban Cables

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Number of conductors
1
Conductor shape
Circular
Material of the inner semi-conductor
Extruded
Insulation
XLPE
Screen
Copper wires
Conductor flexibility
Class 2 IEC 60228

Electrical characteristics

Electrical characteristics

Thermal soil resistivity wet zone
1.5 °K.m/W

Mechanical characteristics

Mechanical characteristics

Cable flexibility
10xD

Usage characteristics

Usage characteristics

Laying depth, center of system
800 mm
Ambient air temperature
30 °C
Ambient ground temperature
20 °C
Max. conductor temperature in service
90 °C
Short-circuit max. conductor temperature
250 °C
Flame retardant
IEC 60332-1-2

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close