M5A4 1*120/16
Nexans ref. M5A4 001254 - Country ref. M5A4 1*120/16//RED
- Outer sheath: PVC
- Colour: Red
- Conductor diameter: 12.8 mm
- Nominal insulation thickness: 5.5 mm
- Screen section: 16 mm²
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 31.0 mm
- Approximate net weight: 1086 kg/km
- Perm current rating in air 30°C: 324 A
- Permissible current rating when buried: 252 A
- Max. DC resistance of the conductor at 20°C: 0.323 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.253 Ohm/km
- Operating temperature, range: -15 ... 55 °C
M5A4 1*150/25
Nexans ref. M5A4 001255 - Country ref. M5A4 1*150/25//RED
- Outer sheath: PVC
- Colour: Red
- Conductor diameter: 14.4 mm
- Nominal insulation thickness: 5.5 mm
- Screen section: 25 mm²
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 32.0 mm
- Approximate net weight: 1891 kg/km
- Perm current rating in air 30°C: 368 A
- Permissible current rating when buried: 281 A
- Max. DC resistance of the conductor at 20°C: 0.264 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.206 Ohm/km
- Operating temperature, range: -15 ... 55 °C
M5A4 1*300/25
Nexans ref. M5A4 001256 - Country ref. M5A4 1*300/25//RED
- Outer sheath: PVC
- Colour: Red
- Conductor diameter: 20.3 mm
- Nominal insulation thickness: 5.5 mm
- Screen section: 25 mm²
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 39.0 mm
- Approximate net weight: 1891 kg/km
- Perm current rating in air 30°C: 577 A
- Permissible current rating when buried: 414 A
- Max. DC resistance of the conductor at 20°C: 0.129 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.1 Ohm/km
- Operating temperature, range: -15 ... 55 °C
M5A4 1*500/35
Nexans ref. M5A4 001257 - Country ref. M5A4 1*500/35//RED
- Outer sheath: PVC
- Colour: Red
- Conductor diameter: 26.2 mm
- Nominal insulation thickness: 5.5 mm
- Screen section: 35 mm²
- Nominal outer sheath thickness: 2.4 mm
- Nominal outer diameter: 46.0 mm
- Approximate net weight: 2758 kg/km
- Perm current rating in air 30°C: 789 A
- Permissible current rating when buried: 537 A
- Max. DC resistance of the conductor at 20°C: 0.0605 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.0794 Ohm/km
- Operating temperature, range: -15 ... 55 °C
M5A4 1*95/16
Nexans ref. M5A4 001700 - Country ref. M5A4 1*95/16
- Outer sheath: PVC
- Colour: Black
- Conductor diameter: 11.7 mm
- Nominal insulation thickness: 5.5 mm
- Screen section: 16 mm²
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 30.0 mm
- Approximate net weight: 984 kg/km
- Perm current rating in air 30°C: 280 A
- Permissible current rating when buried: 221 A
- Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.41 Ohm/km
- Operating temperature, range: -15 ... 55 °C
M5A4P 1*150/25
Nexans ref. M5A4P 000155 - Country ref. M5A4P 1*150/25
- Outer sheath: PE-HD
- Colour: Black
- Conductor diameter: 14.4 mm
- Nominal insulation thickness: 5.5 mm
- Screen section: 25 mm²
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 32.0 mm
- Approximate net weight: 1194 kg/km
- Perm current rating in air 30°C: 368 A
- Permissible current rating when buried: 281 A
- Max. DC resistance of the conductor at 20°C: 0.264 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.206 Ohm/km
- Operating temperature, range: -30 ... 55 °C
M5A4P 1*300/25
Nexans ref. M5A4P 001267 - Country ref. M5A4P 1*300/25
- Outer sheath: PE-HD
- Colour: Black
- Conductor diameter: 20.3 mm
- Nominal insulation thickness: 5.5 mm
- Screen section: 25 mm²
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 39.0 mm
- Approximate net weight: 1774 kg/km
- Perm current rating in air 30°C: 577 A
- Permissible current rating when buried: 414 A
- Max. DC resistance of the conductor at 20°C: 0.129 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.1 Ohm/km
- Operating temperature, range: -30 ... 55 °C
M5A4P 1*95/16
Nexans ref. M5A4P 001700 - Country ref. M5A4P 1*95/16
- Outer sheath: PE
- Colour: Black
- Conductor diameter: 11.7 mm
- Nominal insulation thickness: 5.5 mm
- Screen section: 16 mm²
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 30.0 mm
- Approximate net weight: 905 kg/km
- Perm current rating in air 30°C: 280 A
- Permissible current rating when buried: 221 A
- Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.41 Ohm/km
- Operating temperature, range: -30 ... 55 °C
M6A4 1*500/35
Nexans ref. M6A4 000358 - Country ref. M6A4 1*500/35
- Outer sheath: PVC
- Colour: Black
- Conductor diameter: 26.2 mm
- Nominal insulation thickness: 8.0 mm
- Screen section: 35 mm²
- Nominal outer sheath thickness: 2.6 mm
- Nominal outer diameter: 51.0 mm
- Approximate net weight: 3103 kg/km
- Perm current rating in air 30°C: 789 A
- Permissible current rating when buried: 537 A
- Max. DC resistance of the conductor at 20°C: 0.0605 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.0794 Ohm/km
- Operating temperature, range: -15 ... 55 °C
M6A5 1*120/16//GAM
Nexans ref. M6A5 001118 - Country ref. M6A5 1*120/16//GAM
- Outer sheath: PVC
- Colour: Black
- Conductor diameter: 12.8 mm
- Nominal insulation thickness: 8.0 mm
- Screen section: 16 mm²
- Nominal outer sheath thickness: 2.1 mm
- Nominal outer diameter: 35.0 mm
- Approximate net weight: 1315 kg/km
- Perm current rating in air 30°C: 324 A
- Permissible current rating when buried: 252 A
- Max. DC resistance of the conductor at 20°C: 0.253 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.323 Ohm/km
- Operating temperature, range: -15 ... 55 °C
M6A5 1*120/16//GAM1
Nexans ref. M6A5 002118 - Country ref. M6A5 1*120/16//GAM1
- Outer sheath: PVC
- Colour: Black
- Conductor diameter: 12.8 mm
- Nominal insulation thickness: 8.0 mm
- Screen section: 16 mm²
- Nominal outer sheath thickness: 2.1 mm
- Nominal outer diameter: 35.0 mm
- Approximate net weight: 1315 kg/km
- Perm current rating in air 30°C: 324 A
- Permissible current rating when buried: 252 A
- Max. DC resistance of the conductor at 20°C: 0.253 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.323 Ohm/km
- Operating temperature, range: -15 ... 55 °C
M6A5 1*150/16//GAM
Nexans ref. M6A5 001119 - Country ref. M6A5 1*150/16//GAM
- Outer sheath: PVC
- Colour: Black
- Conductor diameter: 14.4 mm
- Nominal insulation thickness: 8.0 mm
- Screen section: 16 mm²
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 37.0 mm
- Approximate net weight: 1459 kg/km
- Perm current rating in air 30°C: 368 A
- Permissible current rating when buried: 281 A
- Max. DC resistance of the conductor at 20°C: 0.202 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.264 Ohm/km
- Operating temperature, range: -15 ... 55 °C
M6A5 1*150/16//GAM1
Nexans ref. M6A5 002119 - Country ref. M6A5 1*150/16//GAM1
- Outer sheath: PVC
- Colour: Black
- Conductor diameter: 14.4 mm
- Nominal insulation thickness: 8.0 mm
- Screen section: 16 mm²
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 37.0 mm
- Approximate net weight: 1459 kg/km
- Perm current rating in air 30°C: 368 A
- Permissible current rating when buried: 281 A
- Max. DC resistance of the conductor at 20°C: 0.202 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.264 Ohm/km
- Operating temperature, range: -15 ... 55 °C
M6A5 1*185/16//GAM1
Nexans ref. M6A5 002139 - Country ref. M6A5 1*185/16//GAM1
- Outer sheath: PVC
- Colour: Black
- Conductor diameter: 16.2 mm
- Nominal insulation thickness: 8.0 mm
- Screen section: 16 mm²
- Nominal outer sheath thickness: 2.2 mm
- Nominal outer diameter: 39.0 mm
- Approximate net weight: 1635 kg/km
- Perm current rating in air 30°C: 424 A
- Permissible current rating when buried: 317 A
- Max. DC resistance of the conductor at 20°C: 0.164 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.21 Ohm/km
- Operating temperature, range: -15 ... 55 °C
M6A5 1*240/16//GAM
Nexans ref. M6A5 001130 - Country ref. M6A5 1*240/16//GAM
- Outer sheath: PVC
- Colour: Black
- Conductor diameter: 17.9 mm
- Nominal insulation thickness: 8.0 mm
- Screen section: 16 mm²
- Nominal outer sheath thickness: 2.3 mm
- Nominal outer diameter: 48.0 mm
- Approximate net weight: 1846 kg/km
- Perm current rating in air 30°C: 502 A
- Permissible current rating when buried: 367 A
- Max. DC resistance of the conductor at 20°C: 0.125 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.161 Ohm/km
- Operating temperature, range: -15 ... 55 °C
M6A5 1*240/16//GAM1
Nexans ref. M6A5 002130 - Country ref. M6A5 1*240/16//GAM1
- Outer sheath: PVC
- Colour: Black
- Conductor diameter: 17.9 mm
- Nominal insulation thickness: 8.0 mm
- Screen section: 16 mm²
- Nominal outer sheath thickness: 2.3 mm
- Nominal outer diameter: 48.0 mm
- Approximate net weight: 1846 kg/km
- Perm current rating in air 30°C: 502 A
- Permissible current rating when buried: 367 A
- Max. DC resistance of the conductor at 20°C: 0.125 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.161 Ohm/km
- Operating temperature, range: -15 ... 55 °C
M6A5 1*300/16//GAM
Nexans ref. M6A5 001121 - Country ref. M6A5 1*300/16//GAM
- Outer sheath: PVC
- Colour: Black
- Conductor diameter: 20.3 mm
- Nominal insulation thickness: 8.0 mm
- Screen section: 16 mm²
- Nominal outer sheath thickness: 2.4 mm
- Nominal outer diameter: 44.0 mm
- Approximate net weight: 2119 kg/km
- Perm current rating in air 30°C: 577 A
- Permissible current rating when buried: 414 A
- Max. DC resistance of the conductor at 20°C: 0.1 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.129 Ohm/km
- Operating temperature, range: -15 ... 55 °C
M6A5 1*300/16//GAM1
Nexans ref. M6A5 002121 - Country ref. M6A5 1*300/16//GAM1
- Outer sheath: PVC
- Colour: Black
- Conductor diameter: 20.3 mm
- Nominal insulation thickness: 8.0 mm
- Screen section: 16 mm²
- Nominal outer sheath thickness: 2.4 mm
- Nominal outer diameter: 44.0 mm
- Approximate net weight: 2119 kg/km
- Perm current rating in air 30°C: 577 A
- Permissible current rating when buried: 414 A
- Max. DC resistance of the conductor at 20°C: 0.1 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.129 Ohm/km
- Operating temperature, range: -15 ... 55 °C
M6A5 1*400/16//GAM
Nexans ref. M6A5 001132 - Country ref. M6A5 1*400/16//GAM
- Outer sheath: PVC
- Colour: Black
- Conductor diameter: 23.2 mm
- Nominal insulation thickness: 8.0 mm
- Screen section: 16 mm²
- Nominal outer sheath thickness: 2.5 mm
- Nominal outer diameter: 47.0 mm
- Approximate net weight: 2519 kg/km
- Perm current rating in air 30°C: 673 A
- Permissible current rating when buried: 470 A
- Max. DC resistance of the conductor at 20°C: 0.0778 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.0997 Ohm/km
- Operating temperature, range: -15 ... 55 °C
M6A5 1*400/16//GAM1
Nexans ref. M6A5 002132 - Country ref. M6A5 1*400/16//GAM1
- Outer sheath: PVC
- Colour: Black
- Conductor diameter: 23.2 mm
- Nominal insulation thickness: 8.0 mm
- Screen section: 16 mm²
- Nominal outer sheath thickness: 2.5 mm
- Nominal outer diameter: 47.0 mm
- Approximate net weight: 2519 kg/km
- Perm current rating in air 30°C: 673 A
- Permissible current rating when buried: 470 A
- Max. DC resistance of the conductor at 20°C: 0.0778 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.0997 Ohm/km
- Operating temperature, range: -15 ... 55 °C
M6A5 1*630/16//GAM
Nexans ref. M6A5 001631 - Country ref. M6A5 1*630/16//GAM
- Outer sheath: PVC
- Colour: Black
- Conductor diameter: 29.6 mm
- Nominal insulation thickness: 8.0 mm
- Screen section: 16 mm²
- Nominal outer sheath thickness: 2.7 mm
- Nominal outer diameter: 55.0 mm
- Approximate net weight: 3509 kg/km
- Perm current rating in air 30°C: 916 A
- Permissible current rating when buried: 611 A
- Max. DC resistance of the conductor at 20°C: 0.0469 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.0626 Ohm/km
- Operating temperature, range: -15 ... 55 °C
M6A5 1*630/16//GAM1
Nexans ref. M6A5 002631 - Country ref. M6A5 1*630/16//GAM1
- Outer sheath: PVC
- Colour: Black
- Conductor diameter: 29.6 mm
- Nominal insulation thickness: 8.0 mm
- Screen section: 16 mm²
- Nominal outer sheath thickness: 2.7 mm
- Nominal outer diameter: 55.0 mm
- Approximate net weight: 3509 kg/km
- Perm current rating in air 30°C: 916 A
- Permissible current rating when buried: 611 A
- Max. DC resistance of the conductor at 20°C: 0.0469 Ohm/km
- A.C. Conductor resist. 50Hz and at 90 °C: 0.0626 Ohm/km
- Operating temperature, range: -15 ... 55 °C
Description
Description
Standards
-
InternationalIEC 60228; IEC 60332-1-2; IEC 60502-2
1-SCOPE
This specification covers Single core unarmoured cables, conforming to IEC 60502-2 Specifications.
2. CONSTRUCTION
2.1 Conductor
Aluminum conductors, conforming to the applicable requirements of IEC 60228.
2.2 Insulation
Extruded inner semi conductive layer, XLPE insulation and extruded outer semi conductive layer .
2.3 Metallic Screen Layer
Copper wires and open helix copper tape
2.4 Sheath
PVC .
3. TESTS
All tests required by IEC 60502-2 either on Raw material or on finished products.
TEST AT WORKS ACCORDING TO IEC 60502-2 / PRÓBY FABRYCZNE XNUHAKXS, XNUHKXS
Routine Tests / Badania rutynowe:
• Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-2 parag.16.2 / Maks. rezystancja DC żył w temperaturze 20°C zgodnie z IEC 60228 i IEC 60502-2 pkt 16.2
• High voltage test acc. to IEC 60502-2 parag. 16.4 / Próba wysokim napięciem zgodnie z IEC 60502-2 pkt 16.4
• Max. partial discharge test at 1.73 Uo acc. to IEC 60502-2 parag. 16.3 / Badanie maksymalnych wyładowań niezupełnych przy 1,73 Uo zgodnie z IEC 60502-2 pkt 16.3
Liban Cables will carry out these tests on all the lengths and tests certificates will be provided / Firma Liban Cables przeprowadzi te badania dla wszystkich odcinków kabli i dostarczy świadectwa z badań
Sample tests / Badania próbek:
• Check of the build - up and color coding of the cable / Sprawdzenie rozwijania i kolorowych oznaczeń kabla
• Check of dimensions / Sprawdzenie wymiarów
Insulation / Izolacja : according to IEC 60502-2 / zgodnie z IEC 60502-2 Parag. / pkt. 17.5.2
Metallic screen / Ekran metaliczny : according to IEC 60502-2 / zgodnie z IEC 60502-2 Parag. / pkt. 17.7
Oversheath / Powłoka zewnętrzna : according to IEC 60502-2 / zgodnie z IEC 60502-2 Parag. / pkt. 17.5.3
- Hot Set Test for XLPE insulation according to IEC 60502-2 parag. 17.10 /-Badanie stopnia usieciowania izolacji z XLPE zgodnie z IEC 60502-2 pkt 17.10
These tests will be carried out on one length of each size during each inspection . / Badania te – podczas każdej kontroli – zostaną przeprowadzone na jednym odcinku dla każdego rozmiaru kabla.
Tests certificates will be provided by Liban Cables / Świadectwa z badań dostarczy firma Liban Cables
Type tests / Próby typu
Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break ) in accordance with IEC 60502-2. / Charakterystyki mechaniczne materiałów izolacji i powłoki zewnętrznej (wytrzymałość na rozciąganie i wydłużenie przy zerwaniu) zgodnie z IEC 60502-2.
These tests will be carried out on one length of the order / Badania te zostaną przeprowadzone na jednym odcinku z zamówienia
Tests certificates will be provided by Liban Cables / Świadectwa z badań dostarczy firma Liban Cables
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania