Single core Cu Cond. CWS, ARMORED, and PVC Sheath

Products

M2N4W 1*630/35

Nexans ref. M2N4W 000315 - Country ref. M2N4W 1*630/35

  • Armour type: Aluminium Wire
  • Colour: Black
  • Conductor cross-section: 630 mm²
  • Conductor diameter: 30.2 mm
  • Nominal insulation thickness: 3.2 mm
  • Screen section: 35 mm²
  • Nominal armour wire diameter: 2.5 mm
  • Nominal outer sheath thickness: 2.7 mm
  • Nominal outer diameter: 54.0 mm
  • Approximate net weight: 7964 kg/km
  • Perm current rating in air 30°C: 1154 A
  • Permissible current rating when buried: 749 A
  • Max. DC resistance of the conductor at 20°C: 0.0283 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0407 Ohm/km

 

M3N4A 1*240/25

Nexans ref. M3N4A 001241 - Country ref. M3N4A 1*240/25//R

  • Armour type: Aluminium tape
  • Colour: Red
  • Conductor cross-section: 240 mm²
  • Conductor diameter: 18.1 mm
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 25 mm²
  • Nominal armour wire diameter: 0.5 mm
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 37.0 mm
  • Approximate net weight: 3253 kg/km
  • Perm current rating in air 30°C: 641 A
  • Permissible current rating when buried: 469 A
  • Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0981 Ohm/km

 

M3N4W 1*240/25

Nexans ref. M3N4W 001126 - Country ref. M3N4W 1*240/25//R

  • Armour type: Aluminium Wire
  • Colour: Red
  • Conductor cross-section: 240 mm²
  • Conductor diameter: 18.1 mm
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 25 mm²
  • Nominal armour wire diameter: 2 mm
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 39.0 mm
  • Approximate net weight: 3499 kg/km
  • Perm current rating in air 30°C: 641 A
  • Permissible current rating when buried: 469 A
  • Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0981 Ohm/km

 

M3N4W 1*630/35

Nexans ref. M3N4W 001630 - Country ref. M3N4W 1*630/35

  • Armour type: Aluminium Wire
  • Colour: Black
  • Conductor cross-section: 630 mm²
  • Conductor diameter: 30.2 mm
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 35 mm²
  • Nominal armour wire diameter: 2.5 mm
  • Nominal outer sheath thickness: 2.7 mm
  • Nominal outer diameter: 55.0 mm
  • Approximate net weight: 8003 kg/km
  • Perm current rating in air 30°C: 1154 A
  • Permissible current rating when buried: 749 A
  • Max. DC resistance of the conductor at 20°C: 0.0283 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0407 Ohm/km

 

M6N4W 1*240/35

Nexans ref. M6N4W 001241 - Country ref. M6N4W 1*240/35//R

  • Armour type: Aluminium Wire
  • Colour: Red
  • Conductor cross-section: 240 mm²
  • Conductor diameter: 18.1 mm
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 35 mm²
  • Nominal armour wire diameter: 2.5 mm
  • Nominal outer sheath thickness: 2.6 mm
  • Nominal outer diameter: 49.0 mm
  • Approximate net weight: 4456 kg/km
  • Perm current rating in air 30°C: 641 A
  • Permissible current rating when buried: 469 A
  • Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0981 Ohm/km

 

M6N4W 1*500/35

Nexans ref. M6N4W 001962 - Country ref. M6N4W 1*500/35

  • Armour type: Aluminium Wire
  • Colour: Black
  • Conductor cross-section: 500 mm²
  • Conductor diameter: 26.2 mm
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 35 mm²
  • Nominal armour wire diameter: 2.5 mm
  • Nominal outer sheath thickness: 2.9 mm
  • Nominal outer diameter: 60.0 mm
  • Approximate net weight: 7349 kg/km
  • Perm current rating in air 30°C: 1013 A
  • Permissible current rating when buried: 671 A
  • Max. DC resistance of the conductor at 20°C: 0.0366 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0497 Ohm/km

 

M6N4W 1*630/35

Nexans ref. M6N4W 001636 - Country ref. M6N4W 1*630/35

  • Armour type: Aluminium Wire
  • Colour: Black
  • Conductor cross-section: 630 mm²
  • Conductor diameter: 30.2 mm
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 35 mm²
  • Nominal armour wire diameter: 2.5 mm
  • Nominal outer sheath thickness: 3.0 mm
  • Nominal outer diameter: 64.0 mm
  • Approximate net weight: 8939 kg/km
  • Perm current rating in air 30°C: 1154 A
  • Permissible current rating when buried: 749 A
  • Max. DC resistance of the conductor at 20°C: 0.0283 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0407 Ohm/km

 

M7N4W 1*300/25

Nexans ref. M7N4W 000639 - Country ref. M7N4W 1*300/25

  • Armour type: Aluminium Wire
  • Colour: Black
  • Conductor cross-section: 300 mm²
  • Conductor diameter: 20.3 mm
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 25 mm²
  • Nominal armour wire diameter: 2.5 mm
  • Nominal outer sheath thickness: 2.7 mm
  • Nominal outer diameter: 53.0 mm
  • Approximate net weight: 5235 kg/km
  • Perm current rating in air 30°C: 735 A
  • Permissible current rating when buried: 526 A
  • Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
  • A.C. Conductor resist. 50Hz and at 90 °C: 0.0792 Ohm/km

 

Description

Description

Standards

  • International
    IEC 60228; IEC 60332-1-2; IEC 60332-3; IEC 60502-2

1-SCOPE

This specification covers single core armoured cables.
 

2. CONSTRUCTION

2.1 Conductor

Plain, annealed electrolytic copper conductors, circular stranded,conforming to the applicable requirements of IEC 60228.

2.2 Insulation

Extruded inner semi conductive layer, XLPE insulation and  extruded outer semi conductive layer .

2.3 Metallic Screen Layer

Copper wires + Open Helix Copper Tape

2.4 Separation Sheating

PVC.

2.5 Armour

ALUMINUM WIRES OR TAPES .

2.5 Sheath

PVC.

TEST AT WORKS according to IEC 60502-2 for armored cables

Routine Tests

 -          Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-2 parag.16.1 & 16.2

 -          High voltage test acc. to IEC 60502-2  parag. 16.1 & 16.4

 -          Max. partial discharge test  at 1.73 Uo acc. to IEC 60502-2  parag.16.1 & 16.3

Liban Cables will carry out these tests on all the lengths and tests certificates will be provided.

 

Sample Tests

 -          Check of the build - up and color coding of the cable                                                      

 -          Check of dimensions                                                    

            Insulation                      :           according to IEC 60502-2           Parag.  17.5.2

            Separation sheath         :           according to IEC 60502-2           Parag.  17.5.3

            Armouring                     :           according to IEC 60502-2          Parag.  17.7

            Oversheath                   :           according to IEC 60502-2           Parag.  17.5.3

-           Hot Set Test                  :           according to IEC 60502-2           Parag.  17.10

These tests will be carried out on one length of each size during each inspection .

Tests certificates will be provided by Liban Cables

                                                                       

Type Tests

Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break  ) in accordance with IEC 60502-2.

These tests will be carried out on one length of the order .

Tests certificates will be provided by Liban Cables

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Conductor shape
Circular
Material of the inner semi-conductor
Extruded
Insulation
XLPE
Screen
Copper wires + copper tape
Outer sheath
PVC
Conductor flexibility
Class 2 IEC 60228

Electrical characteristics

Electrical characteristics

Thermal soil resistivity wet zone
1.5 °K.m/W

Usage characteristics

Usage characteristics

Laying depth, center of system
800 mm
Ambient air temperature
30 °C
Ambient ground temperature
20 °C
Max. conductor temperature in service
90 °C
Operating temperature, range
-15 ... 55 °C
Short-circuit max. conductor temperature
250 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close