YnHAKXS 6/10KV up to 18/30 KV IEC 60332-3
YnHAKXS 6/10KV up to 18/30 KV IEC 60332-3
XLPE Unarmored cable with aluminum conductor
Read moreYnHAKXS 1*150/50 12/20KV
Nexans ref. M5A4 000571 - Country ref. M5A4 1*150/50//POL-2
- Packaging: Drum (m)
- Conductor cross-section: 150 mm²
- Conductor diameter: 14.4 mm
- Nominal insulation thickness: 5.5 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 35.0 mm
- Approximate net weight: 1698 kg/km
- Test voltage: 42 kV
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
YnHAKXS 1*150/50 6/10KV
Nexans ref. M3A4 009066 - Country ref. M3A4 1*150/50//POL-2
- Packaging: Drum (m)
- Conductor cross-section: 150 mm²
- Conductor diameter: 14.4 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 32.0 mm
- Approximate net weight: 1496 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
YnHAKXS 1*150/50 8.7/15KV
Nexans ref. M4A4 001150 - Country ref. M4A4 1*150/50//POL-2
- Packaging: Drum (m)
- Conductor cross-section: 150 mm²
- Conductor diameter: 14.4 mm
- Nominal insulation thickness: 4.5 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 34.0 mm
- Approximate net weight: 1635 kg/km
- Test voltage: 30 kV
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
YnHAKXS 1*185/50 6/10KV
Nexans ref. M3A4 000055 - Country ref. M3A4 1*185/50//POL-2
- Packaging: Cut to length (m)
- Conductor cross-section: 185 mm²
- Conductor diameter: 16.2 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 1.9 mm
- Nominal outer diameter: 33.0 mm
- Approximate net weight: 1586 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
YnHAKXS 1*240/50 6/10KV
Nexans ref. M3A4 001105 - Country ref. M3A4 1*240/50//POL-2
- Packaging: Cut to length (m)
- Conductor cross-section: 240 mm²
- Conductor diameter: 17.9 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.0 mm
- Nominal outer diameter: 34.0 mm
- Approximate net weight: 1850 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
YnHAKXS 1*240/95 8.7/15KV Cat.C
Nexans ref. M4A4 000601 - Country ref. M4A4 1*240/95//POL-2
- Packaging: Cut to length (m)
- Conductor cross-section: 240 mm²
- Conductor diameter: 17.9 mm
- Nominal insulation thickness: 4.5 mm
- Screen section: 95 mm²
- Nominal outer sheath thickness: 2.1 mm
- Nominal outer diameter: 39.0 mm
- Approximate net weight: 2430 kg/km
- Test voltage: 30 kV
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
YnHAKXS 1*300/50 6/10KV IEC 60332-3 CAT A, CAT B & CAT C
Nexans ref. M3A4 000069 - Country ref. M3A4 1*300/50//POL-2
- Packaging: Cut to length (m)
- Conductor cross-section: 300 mm²
- Conductor diameter: 20.3 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.1 mm
- Nominal outer diameter: 37.0 mm
- Approximate net weight: 2117 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
YnHAKXS 1*630/50 6/10KV IEC 60332-3 CAT A, CAT B & CAT C
Nexans ref. M3A4 000064 - Country ref. M3A4 1*630/50//POL-2
- Packaging: Cut to length (m)
- Conductor cross-section: 630 mm²
- Conductor diameter: 29.6 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.4 mm
- Nominal outer diameter: 49.0 mm
- Approximate net weight: 3460 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
YnHAKXS 3*120/50 6/10KV
Nexans ref. M3A4 000031 - Country ref. M3A4 3*120/50//POL-2
- Packaging: Cut to length (m)
- Conductor cross-section: 120 mm²
- Conductor diameter: 12.8 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.8 mm
- Nominal outer diameter: 60.0 mm
- Approximate net weight: 4260 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
YnHAKXS 3*150/50 6/10KV Cat.C
Nexans ref. M3A4 009031 - Country ref. M3A4 3*150/50//POL-2
- Packaging: Drum (1000m)
- Conductor cross-section: 150 mm²
- Conductor diameter: 14.4 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.9 mm
- Nominal outer diameter: 61.0 mm
- Approximate net weight: 4488 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
YnHAKXS 3*185/50 6/10KV
Nexans ref. M3A4...000161 - Country ref. M3A4 3*185/50//POL-2
- Packaging: Cut to length (m)
- Conductor cross-section: 185 mm²
- Conductor diameter: 16.2 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 3.0 mm
- Nominal outer diameter: 66.0 mm
- Approximate net weight: 5141 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
YnHAKXS 3*240/50 6/10KV
Nexans ref. M3A4...000160 - Country ref. M3A4 3*240/50//POL-2
- Packaging: Cut to length (m)
- Conductor cross-section: 240 mm²
- Conductor diameter: 17.9 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 3.2 mm
- Nominal outer diameter: 69.0 mm
- Approximate net weight: 5851 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
YnHAKXS 3*95/50 6/10KV
Nexans ref. M3A4 000029 - Country ref. M3A4 3*95/50//POL-2
- Packaging: Cut to length (m)
- Conductor cross-section: 95 mm²
- Conductor diameter: 11.7 mm
- Nominal insulation thickness: 3.4 mm
- Screen section: 50 mm²
- Nominal outer sheath thickness: 2.7 mm
- Nominal outer diameter: 57.0 mm
- Approximate net weight: 3857 kg/km
- Test voltage: 21 kV
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
Description
Description
Standards
-
ProductIEC 60502-2
-
TestIEC 60332-1-2; IEC 60332-3
Application
Power use outdoor application, even wet.
Suitable for fixed installations at open air, in tube or canals and underground.
Max. Operation temperature: 90°
Max. Short circuit temperature : 250° (Max 5 s)
Construction
AL/SC/XLPE/SC/SC TAPE/CU WIRES/ low temp. PVC
1. Conductor:
Compacted Round conductor class 2
2. Insulation:
Extruded inner semi conductive layer, XLPE insulation and extruded outer semi conductive layer + Semi-conductive tape
3. Metallic screen layer:
Copper wires with open helix copper tape
4. Outer sheath:
Low Temperature PVC, Red or as per customer requirement
5. Marking:
By Inkjet
6. Packing:
Drums can be wooden or steel
TEST AT WORKS according to IEC 60502-2 & IEC 60332-3
Routine Tests
-Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-2 parag. 16.1 & 16.2
-High voltage test acc. to IEC 60502-2 parag. 16.1 & 16.4
-Max. partial discharge test at 1.73 Uo acc. to IEC 60502-2 parag. 16.1 & 16.3
Liban Cables will carry out these tests on all the lengths and tests certificates will be provided
Sample tests
- Check of the build - up and color coding of the cable
- Check of dimensions
Insulation : according to IEC 60502-2 Parag. 17.5.2
Metallic screen : according to IEC 60502-2 Parag. 17.7
Oversheath : according to IEC 60502-2 Parag. 17.5.3
- Hot Set Test for XLPE insulation according to IEC 60502-2 parag. 17.10
These tests will be carried out on one length of each size during each inspection .
Tests certificates will be provided by Liban Cables
Type tests
Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-2.
Fire retardance test according to IEC 60332-3
These tests will be carried out on one length of the order.
Tests certificates will be provided by Liban Cables
drawing
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania