YnHAKXS 6/10KV up to 18/30 KV IEC 60332-3

Products

YnHAKXS 1*150/50 12/20KV

Nexans ref. M5A4 000571 - Country ref. M5A4 1*150/50//POL-2

  • Packaging: Drum (m)
  • Conductor cross-section: 150 mm²
  • Conductor diameter: 14.4 mm
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 35.0 mm
  • Approximate net weight: 1698 kg/km
  • Test voltage: 42 kV
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV

 

YnHAKXS 1*150/50 6/10KV

Nexans ref. M3A4 009066 - Country ref. M3A4 1*150/50//POL-2

  • Packaging: Drum (m)
  • Conductor cross-section: 150 mm²
  • Conductor diameter: 14.4 mm
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 32.0 mm
  • Approximate net weight: 1496 kg/km
  • Test voltage: 21 kV
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

YnHAKXS 1*150/50 8.7/15KV

Nexans ref. M4A4 001150 - Country ref. M4A4 1*150/50//POL-2

  • Packaging: Drum (m)
  • Conductor cross-section: 150 mm²
  • Conductor diameter: 14.4 mm
  • Nominal insulation thickness: 4.5 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 34.0 mm
  • Approximate net weight: 1635 kg/km
  • Test voltage: 30 kV
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

YnHAKXS 1*185/50 6/10KV

Nexans ref. M3A4 000055 - Country ref. M3A4 1*185/50//POL-2

  • Packaging: Cut to length (m)
  • Conductor cross-section: 185 mm²
  • Conductor diameter: 16.2 mm
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 33.0 mm
  • Approximate net weight: 1586 kg/km
  • Test voltage: 21 kV
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

YnHAKXS 1*240/50 6/10KV

Nexans ref. M3A4 001105 - Country ref. M3A4 1*240/50//POL-2

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Conductor diameter: 17.9 mm
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 34.0 mm
  • Approximate net weight: 1850 kg/km
  • Test voltage: 21 kV
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

YnHAKXS 1*240/95 8.7/15KV Cat.C

Nexans ref. M4A4 000601 - Country ref. M4A4 1*240/95//POL-2

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Conductor diameter: 17.9 mm
  • Nominal insulation thickness: 4.5 mm
  • Screen section: 95 mm²
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 39.0 mm
  • Approximate net weight: 2430 kg/km
  • Test voltage: 30 kV
  • Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV

 

YnHAKXS 1*300/50 6/10KV IEC 60332-3 CAT A, CAT B & CAT C

Nexans ref. M3A4 000069 - Country ref. M3A4 1*300/50//POL-2

  • Packaging: Cut to length (m)
  • Conductor cross-section: 300 mm²
  • Conductor diameter: 20.3 mm
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 37.0 mm
  • Approximate net weight: 2117 kg/km
  • Test voltage: 21 kV
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

YnHAKXS 1*630/50 6/10KV IEC 60332-3 CAT A, CAT B & CAT C

Nexans ref. M3A4 000064 - Country ref. M3A4 1*630/50//POL-2

  • Packaging: Cut to length (m)
  • Conductor cross-section: 630 mm²
  • Conductor diameter: 29.6 mm
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.4 mm
  • Nominal outer diameter: 49.0 mm
  • Approximate net weight: 3460 kg/km
  • Test voltage: 21 kV
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

YnHAKXS 3*120/50 6/10KV

Nexans ref. M3A4 000031 - Country ref. M3A4 3*120/50//POL-2

  • Packaging: Cut to length (m)
  • Conductor cross-section: 120 mm²
  • Conductor diameter: 12.8 mm
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.8 mm
  • Nominal outer diameter: 60.0 mm
  • Approximate net weight: 4260 kg/km
  • Test voltage: 21 kV
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

YnHAKXS 3*150/50 6/10KV Cat.C

Nexans ref. M3A4 009031 - Country ref. M3A4 3*150/50//POL-2

  • Packaging: Drum (1000m)
  • Conductor cross-section: 150 mm²
  • Conductor diameter: 14.4 mm
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.9 mm
  • Nominal outer diameter: 61.0 mm
  • Approximate net weight: 4488 kg/km
  • Test voltage: 21 kV
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

YnHAKXS 3*185/50 6/10KV

Nexans ref. M3A4...000161 - Country ref. M3A4 3*185/50//POL-2

  • Packaging: Cut to length (m)
  • Conductor cross-section: 185 mm²
  • Conductor diameter: 16.2 mm
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 3.0 mm
  • Nominal outer diameter: 66.0 mm
  • Approximate net weight: 5141 kg/km
  • Test voltage: 21 kV
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

YnHAKXS 3*240/50 6/10KV

Nexans ref. M3A4...000160 - Country ref. M3A4 3*240/50//POL-2

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Conductor diameter: 17.9 mm
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 3.2 mm
  • Nominal outer diameter: 69.0 mm
  • Approximate net weight: 5851 kg/km
  • Test voltage: 21 kV
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

YnHAKXS 3*95/50 6/10KV

Nexans ref. M3A4 000029 - Country ref. M3A4 3*95/50//POL-2

  • Packaging: Cut to length (m)
  • Conductor cross-section: 95 mm²
  • Conductor diameter: 11.7 mm
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.7 mm
  • Nominal outer diameter: 57.0 mm
  • Approximate net weight: 3857 kg/km
  • Test voltage: 21 kV
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV

 

Description

Description

Standards

  • Product
    IEC 60502-2
  • Test
    IEC 60332-1-2; IEC 60332-3

Application

Power use outdoor application, even wet.

Suitable for fixed installations at open air, in tube or canals and underground.

Max. Operation temperature: 90°

Max. Short circuit temperature : 250° (Max 5 s)

Construction

AL/SC/XLPE/SC/SC TAPE/CU WIRES/ low temp. PVC

1. Conductor:

Compacted Round conductor class 2

2. Insulation:

Extruded inner semi conductive layer, XLPE insulation and  extruded outer semi conductive layer + Semi-conductive tape

3. Metallic screen layer:

Copper wires with open helix copper tape

4. Outer sheath:

Low Temperature PVC, Red or as per customer requirement

5. Marking:

By Inkjet

6. Packing:

Drums can be wooden or steel

TEST AT WORKS according to IEC 60502-2 & IEC 60332-3

Routine Tests
-Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-2 parag. 16.1 & 16.2
-High voltage test acc. to IEC 60502-2 parag. 16.1 & 16.4
-Max. partial discharge test at 1.73 Uo acc. to IEC 60502-2 parag. 16.1 & 16.3

Liban Cables will carry out these tests on all the lengths and tests certificates will be provided 

                                                                       

Sample tests

 -          Check of the build - up and color coding of the cable                                                      

 -          Check of dimensions                                                    

            Insulation          :           according to IEC 60502-2                       Parag.  17.5.2

            Metallic screen  :           according to IEC 60502-2                       Parag.  17.7

            Oversheath       :           according to IEC 60502-2                       Parag.  17.5.3

- Hot Set Test for XLPE insulation according to IEC 60502-2 parag. 17.10

                                                                       

These tests will be carried out on one length of each size during each inspection . 

Tests certificates will be provided by Liban Cables                                                                      

                                                                       

Type tests

Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break) in accordance with IEC 60502-2. 

Fire retardance test according to IEC 60332-3

These tests will be carried out on one length of the order.

Tests certificates will be provided by Liban Cables

drawing

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Aluminum
Conductor shape
Circular compacted
Material of the inner semi-conductor
Semi-conducting compound
Insulation
XLPE
Material of the external semi-conductor
Extruded fully bonded
Concentric conductor
Copper wires and helical copper tape
Sheath colour
Red

Electrical characteristics

Electrical characteristics

Frequence
50 Hz

Mechanical characteristics

Mechanical characteristics

Cable flexibility
10xD
Mechanical resistance to impacts
Good

Usage characteristics

Usage characteristics

U.V resistance
Yes
Fire retardant
IEC 60332-3
Laying depth, center of system
800 mm
Ambient air temperature
30 °C
Ambient ground temperature
20 °C
Max. conductor temperature in service
90 °C
Short-circuit max. conductor temperature
250 °C
Minimum operating temperature
-35 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close