Hydrocarbon resistant & Fire retardant, Multicore SWA Armored, XLPE insulated, PVC sheathed

Products

EXR 10*2.5

Nexans ref. EXR 017800 - Country ref. EXR 10*2.5//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 2.5 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.25 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 21.0 mm
  • Approximate weight: 816 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 46 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 12*2.5

Nexans ref. EXR 017801 - Country ref. EXR 12*2.5//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 2.5 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.25 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 22.0 mm
  • Approximate weight: 887 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 46 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 2*16 AT+FR

Nexans ref. EXR 025204 - Country ref. EXR 2*16(AT)//FAL

  • Conductor shape: Circular
  • Conductor cross-section: 16 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.25 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 20.0 mm
  • Approximate weight: 864 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 107 A
  • Permissible current rating when buried: 128 A
  • Fire retardant: EN IEC 60332-3-22 (cat A)
  • U.V resistance: No

 

EXR 2*2.5

Nexans ref. EXR 017803 - Country ref. EXR 2*2.5//FMC-C

  • Conductor shape: Circular
  • Conductor cross-section: 2.5 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 0.8 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 13.0 mm
  • Approximate weight: 294 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 46 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 24*2.5

Nexans ref. EXR 017802 - Country ref. EXR 24*2.5//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 2.5 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.25 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 22.0 mm
  • Approximate weight: 887 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 46 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 3*10

Nexans ref. EXR 017751 - Country ref. EXR 3*10//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 10 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.25 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 18.5 mm
  • Approximate weight: 807 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 71 A
  • Permissible current rating when buried: 88 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 3*10 AT+FR

Nexans ref. EXR 025202 - Country ref. EXR 3*10(AT)//FAL

  • Conductor shape: Circular
  • Conductor cross-section: 10 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.25 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 18.5 mm
  • Approximate weight: 790 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 71 A
  • Permissible current rating when buried: 88 A
  • Fire retardant: EN IEC 60332-3-22 (cat A)
  • U.V resistance: No

 

EXR 3*120SM

Nexans ref. EXR 017758 - Country ref. EXR 3*120SM//FMCC

  • Conductor shape: Shaped
  • Conductor cross-section: 120 mm²
  • Nominal insulation thickness: 1.2 mm
  • Nominal armour wire diameter: 2 mm
  • Nominal outer sheath thickness: 2.3 mm
  • Nominal outer diameter: 40.0 mm
  • Approximate weight: 4964 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating in open air: 339 A
  • Permissible current rating when buried: 345 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 3*150SM

Nexans ref. EXR 017759 - Country ref. EXR 3*150SM//FMCC

  • Conductor shape: Shaped
  • Conductor cross-section: 150 mm²
  • Nominal insulation thickness: 1.4 mm
  • Nominal armour wire diameter: 2.5 mm
  • Nominal outer sheath thickness: 2.5 mm
  • Nominal outer diameter: 48.0 mm
  • Approximate weight: 6533 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating in open air: 390 A
  • Permissible current rating when buried: 386 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 3*16

Nexans ref. EXR 017752 - Country ref. EXR 3*16//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 16 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.25 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 21.0 mm
  • Approximate weight: 1046 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 96 A
  • Permissible current rating when buried: 111 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 3*185SM

Nexans ref. EXR 017760 - Country ref. EXR 3*185SM//FMCC

  • Conductor shape: Shaped
  • Conductor cross-section: 185 mm²
  • Nominal insulation thickness: 1.6 mm
  • Nominal armour wire diameter: 2.5 mm
  • Nominal outer sheath thickness: 2.6 mm
  • Nominal outer diameter: 50.0 mm
  • Approximate weight: 7706 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
  • Permissible current rating in open air: 444 A
  • Permissible current rating when buried: 435 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 3*2.5

Nexans ref. EXR 017748 - Country ref. EXR 3*2.5//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 2.5 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 0.8 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 14.0 mm
  • Approximate weight: 356 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 30 A
  • Permissible current rating when buried: 40 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 3*2.5

Nexans ref. EXR 017804 - Country ref. EXR 3*2.5//FMC-C

  • Conductor shape: Circular
  • Conductor cross-section: 2.5 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 0.8 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 13.5 mm
  • Approximate weight: 335 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 30 A
  • Permissible current rating when buried: 40 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 3*240SM

Nexans ref. EXR 017761 - Country ref. EXR 3*240SM//FMCC

  • Conductor shape: Shaped
  • Conductor cross-section: 240 mm²
  • Nominal insulation thickness: 1.7 mm
  • Nominal armour wire diameter: 2.5 mm
  • Nominal outer sheath thickness: 2.8 mm
  • Nominal outer diameter: 56.0 mm
  • Approximate weight: 9619 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
  • Permissible current rating in open air: 522 A
  • Permissible current rating when buried: 504 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 3*25

Nexans ref. EXR 017753 - Country ref. EXR 3*25//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 25 mm²
  • Nominal insulation thickness: 0.9 mm
  • Nominal armour wire diameter: 1.6 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 25.0 mm
  • Approximate weight: 1582 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 127 A
  • Permissible current rating when buried: 141 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 3*35

Nexans ref. EXR 017754 - Country ref. EXR 3*35//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 35 mm²
  • Nominal insulation thickness: 0.9 mm
  • Nominal armour wire diameter: 1.6 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 27.0 mm
  • Approximate weight: 1958 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 157 A
  • Permissible current rating when buried: 170 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 3*4

Nexans ref. EXR 017749 - Country ref. EXR 3*4//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 4 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 0.8 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 15.0 mm
  • Approximate weight: 433 kg/km
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 40 A
  • Permissible current rating when buried: 51 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 3*50

Nexans ref. EXR 017755 - Country ref. EXR 3*50//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 50 mm²
  • Nominal insulation thickness: 1.0 mm
  • Nominal armour wire diameter: 1.6 mm
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 31.0 mm
  • Approximate weight: 2498 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 190 A
  • Permissible current rating when buried: 204 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 3*6

Nexans ref. EXR 017750 - Country ref. EXR 3*6//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 6 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 0.8 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 16.0 mm
  • Approximate weight: 525 kg/km
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 52 A
  • Permissible current rating when buried: 64 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 3*6 AT+FR

Nexans ref. EXR 025201 - Country ref. EXR 3*6(AT)//FAL

  • Conductor shape: Circular
  • Conductor cross-section: 6 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 0.8 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 16.0 mm
  • Approximate weight: 511 kg/km
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 52 A
  • Permissible current rating when buried: 64 A
  • Fire retardant: EN IEC 60332-3-22 (cat A)
  • U.V resistance: No

 

EXR 3*70 AT+FR

Nexans ref. EXR 025203 - Country ref. EXR 3*70SM(AT)//FAL

  • Conductor shape: Shaped
  • Conductor cross-section: 70 mm²
  • Nominal insulation thickness: 1.1 mm
  • Nominal armour wire diameter: 2 mm
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 33.0 mm
  • Approximate weight: 3162 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 242 A
  • Permissible current rating when buried: 252 A
  • Fire retardant: EN IEC 60332-3-22 (cat A)
  • U.V resistance: No

 

EXR 3*70SM

Nexans ref. EXR 017756 - Country ref. EXR 3*70SM//FMCC

  • Conductor shape: Shaped
  • Conductor cross-section: 70 mm²
  • Nominal insulation thickness: 1.1 mm
  • Nominal armour wire diameter: 2 mm
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 33.0 mm
  • Approximate weight: 3190 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 242 A
  • Permissible current rating when buried: 252 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 3*95SM

Nexans ref. EXR 017757 - Country ref. EXR 3*95SM//FMCC

  • Conductor shape: Shaped
  • Conductor cross-section: 95 mm²
  • Nominal insulation thickness: 1.1 mm
  • Nominal armour wire diameter: 2 mm
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 37.0 mm
  • Approximate weight: 4085 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 293 A
  • Permissible current rating when buried: 302 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 4*10

Nexans ref. EXR 017765 - Country ref. EXR 4*10//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 10 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.25 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 20.0 mm
  • Approximate weight: 948 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 71 A
  • Permissible current rating when buried: 88 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 4*16

Nexans ref. EXR 017766 - Country ref. EXR 4*16//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 16 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.6 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 23.0 mm
  • Approximate weight: 1357 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 96 A
  • Permissible current rating when buried: 111 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 4*2.5

Nexans ref. EXR 017762 - Country ref. EXR 4*2.5//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 2.5 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 0.8 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 14.5 mm
  • Approximate weight: 405 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 30 A
  • Permissible current rating when buried: 40 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 4*25 AT+FR

Nexans ref. EXR 025206 - Country ref. EXR 4*25(AT)//FAL

  • Conductor shape: Circular
  • Conductor cross-section: 25 mm²
  • Nominal insulation thickness: 0.9 mm
  • Nominal armour wire diameter: 1.6 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 27.0 mm
  • Approximate weight: 1866 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 127 A
  • Permissible current rating when buried: 141 A
  • Fire retardant: EN IEC 60332-3-22 (cat A)
  • U.V resistance: No

 

EXR 4*4

Nexans ref. EXR 017763 - Country ref. EXR 4*4//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 4 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 0.8 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 16.0 mm
  • Approximate weight: 499 kg/km
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 40 A
  • Permissible current rating when buried: 51 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 4*6

Nexans ref. EXR 017764 - Country ref. EXR 4*6//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 6 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.25 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 18.0 mm
  • Approximate weight: 722 kg/km
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 52 A
  • Permissible current rating when buried: 64 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 4*70 AT+FR

Nexans ref. EXR 025205 - Country ref. EXR 4*70SM(AT)//FAL

  • Conductor shape: Shaped
  • Conductor cross-section: 70 mm²
  • Nominal insulation thickness: 1.1 mm
  • Nominal armour wire diameter: 2 mm
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 37.0 mm
  • Approximate weight: 4011 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 242 A
  • Permissible current rating when buried: 252 A
  • Fire retardant: EN IEC 60332-3-22 (cat A)
  • U.V resistance: No

 

EXR 5*10

Nexans ref. EXR 017788 - Country ref. EXR 5*10//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 10 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.25 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 22.0 mm
  • Approximate weight: 1111 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 71 A
  • Permissible current rating when buried: 88 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 5*16

Nexans ref. EXR 017789 - Country ref. EXR 5*16//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 16 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.6 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 25.0 mm
  • Approximate weight: 1597 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 96 A
  • Permissible current rating when buried: 111 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 5*2.5

Nexans ref. EXR 017785 - Country ref. EXR 5*2.5//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 2.5 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 0.8 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 15.5 mm
  • Approximate weight: 443 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 30 A
  • Permissible current rating when buried: 40 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 5*25

Nexans ref. EXR 017790 - Country ref. EXR 5*25//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 25 mm²
  • Nominal insulation thickness: 0.9 mm
  • Nominal armour wire diameter: 1.6 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 29.0 mm
  • Approximate weight: 2253 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 127 A
  • Permissible current rating when buried: 141 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 5*4

Nexans ref. EXR 017786 - Country ref. EXR 5*4//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 4 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.25 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 18.0 mm
  • Approximate weight: 685 kg/km
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 40 A
  • Permissible current rating when buried: 51 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 5*6

Nexans ref. EXR 017787 - Country ref. EXR 5*6//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 6 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.25 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 19.5 mm
  • Approximate weight: 836 kg/km
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 52 A
  • Permissible current rating when buried: 64 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

EXR 7*2.5

Nexans ref. EXR 017799 - Country ref. EXR 7*2.5//FMCC

  • Conductor shape: Circular
  • Conductor cross-section: 2.5 mm²
  • Nominal insulation thickness: 0.7 mm
  • Nominal armour wire diameter: 1.25 mm
  • Nominal outer sheath thickness: 1.8 mm
  • Nominal outer diameter: 17.5 mm
  • Approximate weight: 620 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 33 A
  • Permissible current rating when buried: 46 A
  • Fire retardant: IEC 60332-3
  • U.V resistance: Yes

 

Description

Description

Standards

  • Product
    IEC 60228; IEC 60502-1
  • Test
    IEC 60332-1-2; IEC 60332-3

Scope

This specification covers XLPE insulated, circular or shaped, multicore armoured cables, rated at 0.6/1 KV according to IEC 60502-1 for use indoors, outdoors, in cable ducts and for direct burial underground, where severe mechanical stresses are present.

Construction

2.1 Conductor

Plain, annealed electrolytic copper conductors, circular stranded, or sectoral stranded, conforming to the applicable requirements of IEC 60228.

2.2 Insulation

XLPE thermosetting material, conforming to the applicable requirements of IEC 60502-1.

2.3 Assembly

Insulated conductors are laid up, filled where necessary with non-hygroscopic material and covered with an extruded thickness of thermoplastic material.

2.4 Armour

Galvanized round wires completely covering the assembly of cores complying to the applicable requirements of IEC 60502-1.

 

2.5 Sheath

Special Hydrocarbon resistant and fire retardant PVC based thermoplastic material, conforming to the applicable requirements of IEC 60502-1.

2.6 TESTS

Conforming to the applicable requirements of IEC 60502-1 either on Raw materials or on finished products.

TEST AT WORKS ACCORDING TO IEC 60502-1 & IEC 60332-3

Routine Tests

 -          Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-1 parag. 15.1 & 15.2

 -          Voltage test acc. to IEC 60502-1  parag.15.1& 15.3

 

Liban Cables will carry out these tests on all the lengths and tests certificates will be provided.                                                                

 

Sample Tests

 -          Check of the build - up and color coding of the cable

 -          Check of dimensions

            Insulation          :           according to IEC 60502-1                      Parag.  16.5.2

            Armour             :           according to IEC 60502-1                       Parag.  16.7

            Oversheath       :           according to IEC 60502-1                      Parag.  16.5.3

 Hot Set Test for XLPE insulation: according to IEC 60502-1                 Parag.  16.9

 

These tests will be carried out on one length of each size during each inspection .

Tests certificates will be provided by Liban Cables

 

Type Tests

Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break ) in accordance with IEC 60502-1.

Fire retardance test according to IEC 60332-3.

These tests will be carried out on one length of the order.

Tests certificates will be provided by Liban Cables.

Drawing Shaped Conductors

Drawing Circular Conductor

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Insulation
XLPE
Armour type
Galvanized steel wires
Outer sheath
PVC

Electrical characteristics

Electrical characteristics

Test voltage
3500 V
Rated Voltage Uo/U (Um)
0,6/1 kV

Mechanical characteristics

Mechanical characteristics

Cable flexibility
10xD

Usage characteristics

Usage characteristics

Operating temperature, range
-15 ... 55 °C
Installation temperature, range
-5 ... 50 °C
Ambient air temperature
30 °C
Maximum operating temperature
90 °C
Short-circuit max. conductor temperature
250 °C
Flame retardant
IEC 60332-1-2

Resources

Resources

Find a Distributor

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close