YHAKXS 6/10KV, 12/20KV, 18/30 KV

Products

YHAKXS 1*120/25 12/20KV NEW

Nexans ref. M5A4 000115 - Country ref. M5A4 1*120/25//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 120 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 31.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*120/50 12/20KV NEW

Nexans ref. M5A4 000111 - Country ref. M5A4 1*120/50//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 120 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 31.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*150/25 12/20KV NEW

Nexans ref. M5A4 010570 - Country ref. M5A4 1*150/25//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 32.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*150/50 12/20KV NEW

Nexans ref. M5A4 000570 - Country ref. M5A4 1*150/50//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 33.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*150/50 6/10KV

Nexans ref. M3A4 009067 - Country ref. M3A4 1x150/50(FL)//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 150 mm²
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 29.0 mm
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*185/25 12/20KV NEW

Nexans ref. M5A4 010571 - Country ref. M5A4 1*185/25//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 185 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 34.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*185/50 12/20KV NEW

Nexans ref. M5A4 000049 - Country ref. M5A4 1*185/50//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 185 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 35.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*185/50 12/20KV NEW

Nexans ref. M5A4 010049 - Country ref. M5A4 1*185/50//POL-3L

  • Packaging: Cut to length (m)
  • Conductor cross-section: 185 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.1 mm
  • Nominal outer diameter: 35.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*185/50 6/10KV NEW

Nexans ref. M3A4 001106 - Country ref. M3A4 1*185/50//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 185 mm²
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 31.0 mm
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*240/25 12/20KV NEW

Nexans ref. M5A4 010572 - Country ref. M5A4 1*240/25//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 36.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*240/50 12/20KV NEW

Nexans ref. M5A4 000110 - Country ref. M5A4 1*240/50//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 37.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*240/50 12/20KV NEW

Nexans ref. M5A4 010110 - Country ref. M5A4 1*240/50//POL-3L

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 37.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*240/50 6/10KV NEW

Nexans ref. M3A4 001103 - Country ref. M3A4 1*240/50//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 33.0 mm
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*240/70 12/20KV

Nexans ref. M5A4 000116 - Country ref. M5A4 1*240/70//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 70 mm²
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 37.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*240/70 6/10KV NEW

Nexans ref. M3A4 011103 - Country ref. M3A4 1*240/70//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 70 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 33.0 mm
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*300/50 12/20KV

Nexans ref. M5A4 011092 - Country ref. M5A4 1*300/50//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 300 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.2 mm
  • Nominal outer diameter: 39.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*300/50 18/30KV

Nexans ref. M6A4 000101 - Country ref. M6A4 1*300/50//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 300 mm²
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.4 mm
  • Nominal outer diameter: 44.0 mm
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*500/50 12/20KV NEW

Nexans ref. M5A4 000500 - Country ref. M5A4 1*500/50//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 500 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.4 mm
  • Nominal outer diameter: 46.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*70/25 12/20KV NEW

Nexans ref. M5A4 000175 - Country ref. M5A4 1*70/25//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 70 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 1.9 mm
  • Nominal outer diameter: 28.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*70/25 18/30KV NEW

Nexans ref. M6A4 011107 - Country ref. M6A4 1*70/25//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 70 mm²
  • Nominal insulation thickness: 8.0 mm
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 2.0 mm
  • Nominal outer diameter: 32.0 mm
  • Rated Voltage Uo/U (Um): 18 / 30 (36) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*70/25 6/10KV NEW

Nexans ref. M3A4 001107 - Country ref. M3A4 1*70/25//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 70 mm²
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 25 mm²
  • Nominal outer sheath thickness: 1.7 mm
  • Nominal outer diameter: 24.0 mm
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 1*800/50 12/20KV

Nexans ref. M5A4 000501 - Country ref. M5A4 1*800/50//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 800 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.7 mm
  • Nominal outer diameter: 56.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 10xD
  • Bending factor when laying: 20 (xD)

 

YHAKXS 3*120/50 6/10KV

Nexans ref. M3A4 001031 - Country ref. M3A4 3*120/50//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 120 mm²
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 2.8 mm
  • Nominal outer diameter: 56.0 mm
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV
  • Cable flexibility: 8xD
  • Bending factor when laying: 16 (xD)

 

YHAKXS 3*185/50 12/20KV NEW

Nexans ref. M5A4 001500 - Country ref. M5A4 3*185/50//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 185 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 3.3 mm
  • Nominal outer diameter: 73.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 8xD
  • Bending factor when laying: 16 (xD)

 

YHAKXS 3*185/50 12/20KV NEW

Nexans ref. M5A4 011500 - Country ref. M5A4 3*185/50//POL-3L

  • Packaging: Cut to length (m)
  • Conductor cross-section: 185 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 3.3 mm
  • Nominal outer diameter: 73.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 8xD
  • Bending factor when laying: 16 (xD)

 

YHAKXS 3*185/50 6/10KV

Nexans ref. M3A4...000075 - Country ref. M3A4 3*185/50//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 185 mm²
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 3.0 mm
  • Nominal outer diameter: 64.0 mm
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV
  • Cable flexibility: 8xD
  • Bending factor when laying: 16 (xD)

 

YHAKXS 3*240/50 12/20KV NEW

Nexans ref. M5A4 001000 - Country ref. M5A4 3*240/50//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 3.5 mm
  • Nominal outer diameter: 77.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 8xD
  • Bending factor when laying: 16 (xD)

 

YHAKXS 3*240/50 12/20KV NEW

Nexans ref. M5A4 011000 - Country ref. M5A4 3*240/50//POL-3L

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Nominal insulation thickness: 5.5 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 3.5 mm
  • Nominal outer diameter: 77.0 mm
  • Rated Voltage Uo/U (Um): 12 / 20 (24) kV
  • Cable flexibility: 8xD
  • Bending factor when laying: 16 (xD)

 

YHAKXS 3*240/50 6/10KV NEW

Nexans ref. M3A4 000071 - Country ref. M3A4 3*240/50//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 50 mm²
  • Nominal outer sheath thickness: 3.2 mm
  • Nominal outer diameter: 68.0 mm
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV
  • Cable flexibility: 8xD
  • Bending factor when laying: 16 (xD)

 

YHAKXS 3*240/70 6/10KV NEW

Nexans ref. M3A4 010500 - Country ref. M3A4 3*240/70//POL-3

  • Packaging: Cut to length (m)
  • Conductor cross-section: 240 mm²
  • Nominal insulation thickness: 3.4 mm
  • Screen section: 70 mm²
  • Nominal outer sheath thickness: 3.2 mm
  • Nominal outer diameter: 67.0 mm
  • Rated Voltage Uo/U (Um): 6 / 10 (12) kV
  • Cable flexibility: 8xD
  • Bending factor when laying: 16 (xD)

 

Description

Description

Standards

  • International
    IEC 60332-1-2; IEC 60502-2

AL/SC/XLPE/SC/SC TAPE/CU WIRES/ low temp. PVC

 

APPLICATION

Power use outdoor application, even wet.

Suitable for fixed installations at open air, in tube or canals and underground.

Max. Operation temperature: 90°

Max. Short circuit temperature : 250° (Max 5 s)

 

CONSTRUCTION

1. Conductor:

Compacted Round conductor class 2

2. Insulation:

Extruded inner semi conductive layer, XLPE insulation and  extruded outer semi conductive layer + Semi-conductive tape

3. Metallic screen layer:

Copper wires with open helix copper tape

4. Outer sheath:

Low Temperature PVC, Red or as per customer requirement

5. Marking:

By Inkjet

6. Packing:

Drums can be wooden or steel

TEST AT WORKS / PRÓBY FABRYCZNE

Routine Tests / Badania rutynowe:

• Max. DC conductors resistance at 20°C acc. to IEC 60228 & IEC 60502-2 parag.16.2 / Maks. rezystancja DC żył w temperaturze 20°C zgodnie z IEC 60228 i IEC 60502-2 pkt 16.2

• High voltage test acc. to IEC 60502-2 parag. 16.4 / Próba wysokim napięciem zgodnie z IEC 60502-2 pkt 16.4

• Max. partial discharge test at 1.73 Uo acc. to IEC 60502-2 parag. 16.3 / Badanie maksymalnych wyładowań niezupełnych przy 1,73 Uo zgodnie z IEC 60502-2 pkt 16.3

 

Liban Cables will carry out these tests on all the lengths and tests certificates will be provided  / Firma Liban Cables przeprowadzi te badania dla wszystkich odcinków kabli i dostarczy świadectwa z badań

 

Sample tests / Badania próbek:

• Check of the build - up and color coding of the cable / Sprawdzenie rozwijania i kolorowych oznaczeń kabla

• Check of dimensions / Sprawdzenie wymiarów

Insulation / Izolacja        :           according to IEC 60502-2 / zgodnie z IEC 60502-2          Parag. / pkt.      17.5.2

Metallic screen / Ekran metaliczny          :           according to IEC 60502-2 / zgodnie z IEC 60502-2          Parag. / pkt.            17.7

Oversheath / Powłoka zewnętrzna           :           according to IEC 60502-2 / zgodnie z IEC 60502-2          Parag. / pkt.            17.5.3

- Hot Set Test for XLPE insulation according to IEC 60502-2 parag. 17.10 /-Badanie stopnia usieciowania izolacji z XLPE zgodnie z IEC 60502-2 pkt 17.10

 

These tests will be carried out on one length of each size during each inspection . / Badania te – podczas każdej kontroli – zostaną przeprowadzone na jednym odcinku dla każdego rozmiaru kabla.

Tests certificates will be provided by Liban Cables / Świadectwa z badań dostarczy firma Liban Cables

 

Type tests / Próby typu

Mechanical characteristics on insulation and sheaths material (tensile strength and elongation at break ) in accordance with IEC 60502-2. / Charakterystyki mechaniczne materiałów izolacji i powłoki zewnętrznej (wytrzymałość na rozciąganie i wydłużenie przy zerwaniu) zgodnie z IEC 60502-2.

These tests will be carried out on one length of the order / Badania te zostaną przeprowadzone na jednym odcinku z zamówienia

Tests certificates will be provided by Liban Cables / Świadectwa z badań dostarczy firma Liban Cables

DRAWING YnHAKXS

Characteristics

Characteristics

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Good

Usage characteristics

Usage characteristics

U.V resistance
Yes
Laying depth, center of system
800 mm
Ambient air temperature
30 °C
Ambient ground temperature
20 °C
Max. conductor temperature in service
90 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close